Carrier PCV015-060 - Manual
Carrier PCV015-060 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 3 – Table 1 — 50PCH,PCV Unit Physical Data; CAUTION
- Page 4 – Fig. 1 — 50PCH Unit Dimensions; UNIT HANGER DETAIL
- Page 5 – Fig. 2 — Typical Installation — 50PCH Units; UNIT HANGER ISOLATION DETAIL
- Page 6 – Fig. 3 — 50PCV Unit Dimensions
- Page 7 – Step 3 — Locate Unit —; Fig. 4 — Typical Vertical Installation —
- Page 8 – Fig. 7 — Horizontal Hanger Bracket; COMPRE; Fig. 8 — 50PCV Units Mounted with
- Page 9 – Step 7 — Pipe Connections —; Table 2 — Metal Hose Minimum Bend Radii; Vent; Fig. 11 — Vertical Condensate Connection
- Page 11 – omplet
- Page 16 – WH
- Page 20 – Fig
- Page 22 – Step 9 — Wire Field Controls; only; NOTE: Low voltage connector may be removed for easy installation.; TERMINAL STRIP P2; THERMO
- Page 23 – view; WARNING; OUTER JACKET
- Page 24 – System Checkout —; CONNECT THE BLUE WIRE TO:; Fig. 30 — Blower Speed Selection
- Page 25 – REHEAT EXTERNAL STATIC PRESSURE (ESP) LOSS
- Page 27 – Operating Limits; When the disconnect switch is closed, high voltage is
- Page 28 – Table 14 — Operating Limits — 50PCH,PCV Units; Scroll Compressor Rotation —; Table 15 — Water Temperature Change; Dry Bulb
- Page 31 – Display Interface
- Page 32 – Flow Regulation —; Table 23 — Coaxial Water Pressure Drop
- Page 33 – Table 25 — Antifreeze Percentages by Volume
- Page 34 – Units with WSHP Open Multiple Protocol —
- Page 37 – Retry Mode —; Table 26 — Complete C Control Current LED
- Page 40 – Fig. 34 — Thermistor Nominal Resistance; Fig. 35 — FP1 and FP2 Thermistor Location; COAX —
- Page 41 – Table 29 — Troubleshooting
- Page 43 – APPENDIX A — WSHP OPEN SCREEN CONFIGURATION
- Page 44 – APPENDIX A — WSHP OPEN SCREEN CONFIGURATION (cont)
- Page 46 – APPENDIX A — WSHP SCREEN OPEN CONFIGURATION (cont)
- Page 52 – HEATING CYCLE ANALYSIS; = SUCTION TEMPERATURE – SUCTION SATURATION TEMPERATURE; SUBCOOLING; = DISCHARGE SATURATION TEMPERATURE – LIQUID LINE TEMPERATURE
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Catalog No. 04-53500049-01
Printed in U.S.A.
Form 50PC-1SI
Pg 1
7-09
Replaces: New
Installation, Start-Up, and
Service Instructions
CONTENTS
Page
SAFETY CONSIDERATIONS
. . . . . . . . . . . . . . . . . . .1,2
GENERAL
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
INSTALLATION
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-24
Step 1 — Check Jobsite
. . . . . . . . . . . . . . . . . . . . . . . . 2
Step 2 — Check Unit
. . . . . . . . . . . . . . . . . . . . . . . . . . . 2
• STORAGE
• PROTECTION
• INSPECT UNIT
Step 3 — Locate Unit
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
• FIELD CONVERSION OF DISCHARGE AIR
Step 4 — Mount the Unit
. . . . . . . . . . . . . . . . . . . . . . . . . 8
• HORIZONTAL UNITS
• VERTICAL UNITS
Step 5 — Check Duct System
. . . . . . . . . . . . . . . . . . . . 8
• SOUND ATTENUATION
• EXISTING DUCT SYSTEM
Step 6 — Install Condensate Drain
. . . . . . . . . . . . . . . 8
• HORIZONTAL UNITS
• VERTICAL UNITS
• VENTING
Step 7 — Pipe Connections
. . . . . . . . . . . . . . . . . . . . . . 9
• WATER LOOP APPLICATIONS
• GOUND LOOP APPLICATIONS
• INSTALLATION OF SUPPLY AND RETURN HOSE
KIT
Step 8 — Wire Field Power Supply
. . . . . . . . . . . . . . 10
• POWER CONNECTION
• SUPPLY VOLTAGE
• 208-VOLT OPERATION
• 460-VOLT OPERATION
Step 9 — Wire Field Controls
. . . . . . . . . . . . . . . . . . . . 22
• THERMOSTAT CONNECTIONS
• WATER FREEZE PROTECTION
• AIR COIL FREEZE PROTECTION
• ACCESSORY CONNECTIONS
• WATER SOLENOID VALVES
• WSHP OPEN WIRING
PRE-START-UP
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24,25
System Checkout
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
PSC Blower Speed Selection
. . . . . . . . . . . . . . . . . . 24
FIELD SELECTABLE INPUTS
. . . . . . . . . . . . . . . .26,27
Complete C Control Jumper Settings
. . . . . . . . . . . 26
Complete C Control DIP Switches
. . . . . . . . . . . . . . 26
Deluxe D Control Jumper Settings
. . . . . . . . . . . . . 26
Deluxe D Control DIP Switches
. . . . . . . . . . . . . . . . 26
Deluxe D Control Accessory Relay
Configurations
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Water Valve (Slow Opening)
. . . . . . . . . . . . . . . . . . . 27
Outside Air Damper (OAD)
. . . . . . . . . . . . . . . . . . . . 27
START-UP
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27-33
Operating Limits
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Scroll Compressor Rotation
. . . . . . . . . . . . . . . . . . . . . 28
Unit Start-Up Cooling Mode
. . . . . . . . . . . . . . . . . . . . . 28
Page
Unit Start-Up Heating Mode
. . . . . . . . . . . . . . . . . . . . . 31
Unit Start-Up with WSHP Open Controls
. . . . . . . . 31
Flow Regulation
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Flushing
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Antifreeze
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Cooling Tower/Boiler Systems
. . . . . . . . . . . . . . . . . . 33
OPERATION
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33-37
Power Up Mode
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Units with Aquazone Complete C Control
. . . . . . . 33
Units with Aquazone Deluxe D Control
. . . . . . . . . . 33
Units with WSHP Open Multiple Protocol
. . . . . . . . 34
COMPLETE C AND DELUXE D BOARD
SYSTEM TEST
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37,38
Test Mode
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
WSHP Open Test Mode
. . . . . . . . . . . . . . . . . . . . . . . . . . 37
Retry Mode
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Aquazone Deluxe D Control LED Indicators
. . . . . 37
SERVICE
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38-40
Filters
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Water Coil
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Condensate Drain Pans
. . . . . . . . . . . . . . . . . . . . . . . . . 38
Refrigerant System
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Compressor
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Fan Motors
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Condensate Drain Cleaning
. . . . . . . . . . . . . . . . . . . 38
Air Coil Cleaning
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Condenser Cleaning
. . . . . . . . . . . . . . . . . . . . . . . . . . 39
Checking System Charge
. . . . . . . . . . . . . . . . . . . . . 39
Refrigerant Charging
. . . . . . . . . . . . . . . . . . . . . . . . . 39
Air Coil Fan Motor Removal
. . . . . . . . . . . . . . . . . . . . . 39
Replacing the WSHP Open Controller’s
Battery
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
TROUBLESHOOTING
. . . . . . . . . . . . . . . . . . . . . . . . 40-42
Thermistor
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Control Sensors
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
WSHP Open Controller
. . . . . . . . . . . . . . . . . . . . . . . . . . 40
APPENDIX A — WSHP OPEN SCREEN
CONFIGURATION
. . . . . . . . . . . . . . . . . . . . . . . . . . 43-48
50PCH,PCV START-UP CHECKLIST
. . . . . CL-1, CL-2
SAFETY CONSIDERATIONS
Installation and servicing of air-conditioning equipment can
be hazardous due to system pressure and electrical compo-
nents. Only trained and qualified service personnel should
install, repair, or service air-conditioning equipment.
Untrained personnel can perform basic maintenance func-
tions of cleaning coils and filters and replacing filters. All other
operations should be performed by trained service personnel.
When working on air-conditioning equipment, observe
precautions in the literature, tags and labels attached to the unit,
and other safety precautions that may apply.
IMPORTANT: Read the entire instruction manual before
starting installation.
AQUAZONE™
50PCH,PCV015-060
Compact High-Efficiency Water Source Heat Pumps
with PURON
®
Refrigerant (R-410A)
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
3 or an equivalent protective covering. Cap open ends of pipes stored on the jobsite. This precaution is especially important in areas where painting, plastering, or spraying of fireproof mate- rial, etc. is not yet complete. Foreign material that accumulates within the units can prevent proper star...
4 50PCH015-060 UNITS NOTES: 1. While clear access to all removable panels is not required, installer should take care to comply with all building codes and allow adequate clearancefor future field service. 2. Horizontal units shipped with filter bracket only. This bracket should be removed for retur...
5 Fig. 2 — Typical Installation — 50PCH Units UNIT HANGER ISOLATION DETAIL