Carrier 48FC Series - Installation Manual

Carrier 48FC Series

Carrier 48FC Series Air Conditioner – Installation Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
Page: / 60

Table of Contents:

  • Page 2 – Gas Valve
  • Page 3 – See Fig. 1 for 48FC model number nomenclature. See Fig. 2 for; Rated Indoor Airflow; rating for the units covered in this document.; WARNING; /8 in. NPT pipe plug must be installed to prevent gas leaks.; Manifold; Table 1 — Rated Indoor Airflow; MODEL NUMBER
  • Page 5 – Fig. 2 — Unit Dimensional Drawing
  • Page 8 – Table 2 — Operating Weights; Base Unit
  • Page 9 – Fig. 3 — Roof Curb Details
  • Page 10 – Fig. 4 — Unit Leveling Tolerances; Step 5 — Field Fabricate Ductwork; CAUTION
  • Page 12 – Fig. 8 — Horizontal Duct Panels In Place; Step 8 — Install Outside Air Hood; Fig. 9 — Typical Access Panel Locations; Filter Access Panel
  • Page 13 – Step 9 — Units with Hinged Panels Only; Fig. 14 — Compressor Door Latch Location; Step 10 — Install Flue Hood; Fig. 15 — Flue Hood Details; Step 11 — Install Gas Piping; Screw; Compressor Door
  • Page 15 – Fig. 19 — Gas Line Piping for 3 to 6 Ton Units
  • Page 17 – Fig. 23 — Orifice Hole; Step 12 — Install External Condensate Trap and; Fig. 25 — Condensate Drain Pan Piping Details; Step 13 — Make Electrical Connections; Burner; Base Rail
  • Page 18 – Field-Install the NFD Shaft and Handle; Fig. 28 — NFD Enclosure Location; Units Without Non-Fused Disconnect Option
  • Page 19 – Fig. 30 — Convenience Outlet Location; Installing Weatherproof Cover
  • Page 20 – Non-Powered Convenience Outlet
  • Page 21 – Fig. 34 — Powered Convenience Outlet Wiring; Fuse On Power Type
  • Page 22 – Fig. 35 — Low-Voltage Thermostat Connections; Thermostat Wiring, Units Without Thru-Base Connection Kit; Fig. 36 — Field Control Wiring Raceway; Humidi-MiZer Space RH Controller; Fig. 37 — Accessory Field-Installed Humidistat; Raceway
  • Page 23 – Connecting the Carrier Humidistat (HL38MG029); Fig. 39 — Humidistat Connections to UCB; Humidistat
  • Page 28 – Integrated Gas Controller; Fig. 45 — Flue Gas Pressure Switch and Pressure
  • Page 29 – Fig. 47 — Typical IGC Control Wiring Diagram; UNIT CONTROL; Table 7 — IGC Board LED Alarm Codes
  • Page 30 – Dehumidification System; Table 8 — Humidi-MiZer System Control Modes
  • Page 33 – Interface Overview; NOTE: QR codes in this image are for reference only.
  • Page 34 – Functions; Fig. 59 — Hysteresis Settings; Power; Table 9 — LED Indication; On
  • Page 37 – sensor is connected); FAN TYPE
  • Page 39 – Mounting Devices Connected to the Economizer Controller; Fig. 60 — EconomizerONE Control Wiring
  • Page 40 – Table 18 — EconomizerONE Control Wiring Settings; LABEL
  • Page 41 – Connecting Peripheral Devices to the Economizer Controller; Fig. 61 — Temperature Sensor Connection
  • Page 42 – Outside; Connect to the
  • Page 43 – Administrator
  • Page 44 – Table 19 — Status Display
  • Page 45 – Table 20 — Parameter Settings — Basic
  • Page 47 – Table 23 — Alarm Parameters; Table 24 — Test Commands
  • Page 48 – Enthalpy Control Sensor Configuration; Table 25 — Enter Running State; Table 26 — Enter Configuration State and Restart
  • Page 49 – Actuator
  • Page 51 – Table 28 — California Title 24 Regional High Limit; Table 29 — HH57LW001 Sensor Wiring Terminations
  • Page 53 – Table 30 — Operating Issues and Concerns
  • Page 54 – Installed Option RTU Open Multi-Protocol Controller Controls,; SystemVu; Series Single Package Rooftop Units with SystemVu Controller; Controller Options; Completing Return Air Smoke Sensor Installation; Shipping Position
  • Page 56 – Step 16 — Fan Speed Set Up; Fig. 73 — UCB Fan Speed Controls — 3-Phase Units; Fan Speed Set Up Controls
  • Page 57 – Calculator; CFM; Economizer; UNIT MODEL
  • Page 58 – RPM; DETERMINE RPM FROM BELOW; UNIT CONFIGURATIONS; IDF VENT SPD -RPM; SETTINGS
  • Page 59 – NOTE: To avoid injury to personnel and damage to equipment or
Loading the manual
Page 1

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Catalog No. 04-53480419-01

Printed in U.S.A.

Form No. 48FC-4-7-05SI Rev. B

Pg 1

3-24

Replaces: 48FC-4-7-04SI

Installation Instructions

CONTENTS

Page

SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . 1
MODEL NUMBER NOMENCLATURE AND

DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Rated Indoor Airflow . . . . . . . . . . . . . . . . . . . . . . . . . . 3
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Jobsite Survey . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Step 1 — Plan for Unit Location . . . . . . . . . . . . . . . . 8

• ROOF MOUNT

Step 2 — Plan for Sequence of Unit Installation . . . 8

• CURB-MOUNTED INSTALLATION

• PAD-MOUNTED INSTALLATION

• FRAME-MOUNTED INSTALLATION

Step 3 — Inspect Unit . . . . . . . . . . . . . . . . . . . . . . . . . 8
Step 4 — Provide Unit Support . . . . . . . . . . . . . . . . . 8

• ROOF CURB MOUNT

• SLAB MOUNT (HORIZONTAL UNITS ONLY)

• ALTERNATE UNIT SUPPORT (IN LIEU OF CURB OR

SLAB MOUNT)

Step 5 — Field Fabricate Ductwork . . . . . . . . . . . . . 10
Step 6 — Rig and Place Unit . . . . . . . . . . . . . . . . . . 10

• POSITIONING ON CURB

Step 7 — Convert to Horizontal and Connect

Ductwork (When Required) . . . . . . . . . . . . . . . . . 11

Step 8 — Install Outside Air Hood . . . . . . . . . . . . . . 12

• ECONOMIZER AND TWO-POSITION DAMPER HOOD

PACKAGE REMOVAL AND SETUP (FACTORY

OPTION)

• ECONOMIZER AND 2-POSITION HOOD

Step 9 — Units with Hinged Panels Only . . . . . . . . 13
Step 10 — Install Flue Hood . . . . . . . . . . . . . . . . . . . 13
Step 11 — Install Gas Piping . . . . . . . . . . . . . . . . . . 13

• FACTORY OPTION THRU-BASE CONNECTIONS

(GAS CONNECTIONS)

Step 12 — Install External Condensate Trap and

Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Step 13 — Make Electrical Connections . . . . . . . . . 17

• FIELD POWER SUPPLY

• UNITS WITH FACTORY-INSTALLED NON-FUSED

DISCONNECT

• UNITS WITHOUT FACTORY-INSTALLED

NON-FUSED DISCONNECT

• ALL UNITS

• CONVENIENCE OUTLETS

• FACTORY-OPTION THRU-BASE CONNECTIONS

(ELECTRICAL CONNECTIONS)

• UNITS WITHOUT THRU-BASE CONNECTIONS

(ELECTRICAL CONNECTIONS)

• FIELD CONTROL WIRING

• THERMOSTAT

• HEAT ANTICIPATOR SETTINGS

• HUMIDI-MIZER

®

CONTROL CONNECTIONS

• TYPICAL UNIT WIRING DIAGRAMS

Integrated Gas Controller . . . . . . . . . . . . . . . . . . . . . 28
Humidi-MiZer

®

Dehumidification System

(Optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

• NORMAL COOLING

• DEHUM/MECH COOLING (SUBCOOLING) MODE

• DEHUMIDIFICATION (HOT GAS REHEAT) MODE

• REHEAT CONTROL

EconomizerONE (Factory Option) . . . . . . . . . . . . . . 33

• ECONOMIZER SETTINGS

• WIRING

• SETUP AND CONFIGURATION

• INSTALLING OPTIONAL HH57LW001 SINGLE

OUTSIDE AIR ENTHALPY SENSOR

• CHECKOUT

• TROUBLESHOOTING

RTU Open Controller (Factory Option) . . . . . . . . . . 54
SystemVu

™

Controller (Factory Option) . . . . . . . . . 54

Controller Options . . . . . . . . . . . . . . . . . . . . . . . . . . . 54

• LOW AMBIENT

Smoke Detectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Step 14 — Adjust Factory-Installed Options . . . . . . 55

• SMOKE DETECTORS

• ECONOMIZERONE OCCUPANCY SWITCH

Step 15 — Install Accessories . . . . . . . . . . . . . . . . . 55
Step 16 — Fan Speed Set Up . . . . . . . . . . . . . . . . . . 56

• UNITS WITH ELECTROMECHANICAL CONTROLS

• UNITS WITH SYSTEMVU

™

CONTROLS

START-UP CHECKLIST . . . . . . . . . . . . . . . . . . . . . CL-1

SAFETY CONSIDERATIONS

Installation and servicing of air-conditioning equipment can be

hazardous due to system pressure and electrical components. Only

trained and qualified service personnel should install, repair, or

service air-conditioning equipment.
Untrained personnel can perform basic maintenance functions of

cleaning coils and filters and replacing filters. All other operations

should be performed by trained service personnel. When working

on air-conditioning equipment, observe precautions in the

literature, tags and labels attached to the unit, and other safety

precautions that may apply.
Follow all safety codes, including ANSI (American National

Standards Institute) Z223.1. Wear safety glasses and work gloves.

Use quenching cloth for unbrazing operations. Have fire

extinguisher available for all brazing operations.
It is important to recognize safety information. This is the safety-

alert symbol

. When you see this symbol on the unit and in

instructions or manuals, be alert to the potential for personal

injury.
Understand the signal words DANGER, WARNING, CAUTION,

and NOTE. These words are used with the safety-alert symbol.

WeatherMaker

®

48FC**04-07

Single Package Rooftop

Gas Heating/Electric Cooling Unit

with Puron

®

(R-410A) Refrigerant

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Was this manual helpful?

About this manual

Brand
Carrier
Model
48FC Series
Document type
Installation Manual
Category
Air Conditioner
Language(s)
English
Pages
60
Format
PDF

Summary

Page 2 - Gas Valve

2 DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies hazards which could result in personal injury or death. CAUTION is used to identify unsafe practices, which may result in minor personal injury or product and property damage. NOTE is...

Page 3 - See Fig. 1 for 48FC model number nomenclature. See Fig. 2 for; Rated Indoor Airflow; rating for the units covered in this document.; WARNING; /8 in. NPT pipe plug must be installed to prevent gas leaks.; Manifold; Table 1 — Rated Indoor Airflow; MODEL NUMBER

3 MODEL NUMBER NOMENCLATURE AND DIMENSIONS See Fig. 1 for 48FC model number nomenclature. See Fig. 2 for unit dimensional drawings. Figure 2 also shows service clearance dimensions. Rated Indoor Airflow Table 1 lists the rated indoor airflow used for the AHRI efficiency rating for the units covered ...

Page 5 - Fig. 2 — Unit Dimensional Drawing

Ask a question

Up to 3 photos. Max 5 MB each. Formats: JPG, JPEG, PNG, WebP.