Carrier 13 50XP- Manual
Carrier 13 50XP– Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Thermostatic Expansion Valve; fl; fl; fl; Table of contents; Page
- Page 3 – Model number nomenclature; COOLING CAPACITIES AND EFFICIENCIES
- Page 4 – Physical data
- Page 5 – Options and accessories; ELECTRIC HEATERS; MINIMUM AIRFLOW FOR RELIABLE ELECTRIC HEATER OPERATION
- Page 9 – Accessory dimensions
- Page 10 – External static pressure; V Select unit that corresponds to power source available.; Selection Procedure
- Page 11 – Standard ECM Indoor Motor; COOLING CAPACITIES
- Page 14 – ELECTRIC HEAT PRESSURE DROP TABLES
- Page 16 – Typical piping and wiring
- Page 17 – Application data
- Page 18 – Electrical data
- Page 22 – Operating sequence; Cooling —; When the system thermostat calls for cooling, 24; Heating; — If accessory electric heaters are installed, on a; Controls
- Page 23 – Guide specifications
PERFORMANCE™ 13 50XP
SINGLE-PACKAGED ELECTRIC COOLING UNITS
WITH PURON® (R-410A) REFRIGERANT
2 to 5 Nominal Tons
Product Data
UNIT 50XP
Single-Packaged Products with
Energy-Saving Features and Puron®
refrigerant.
• Low Sound Levels
• 13 SEER
• Variable Speed Blower-Standard
• Factory Installed TXV
Features/Bene
fi
ts
One-piece cooling unit with optional
electric heater, low installation cost,
dependable performance and easy
maintenance.
Ef
fi
cient operation
High-ef
fi
ciency design
with a SEER
(Seasonal Energy Ef
fi
ciency Ratio)
of 13.0.
Puron® Environmentally Sound
Refrigerant
is Carrier’s unique
refrigerant designed to help protect the
environment. Puron is an HFC
refrigerant which does not contain
chlorine that can harm the ozone layer.
The most important advantage of
Puron refrigerant is that it has not been
banned in future air conditioning
systems as the traditional refrigerant
R-22 has been. Puron refrigerant is in
service in thousands of systems
proving highly reliable,
environmentally sound performance.
IdealHumidity™ Technology
featuring Thermidistat control and
Variable Speed Blower motor
that
provides greater comfort, humidity
control, and energy ef
fi
ciency. You can
expect up to 30 times better
dehumidi
fi
cation; economical constant
fan for less than $50 a year, which
provides improved indoor air quality
and more even temperatures from room
to room; and reduced indoor noise due
to lower air velocity. In addition, you’ll
realize improved installation
fl
exibility
with 3 different air
fl
ow choices for best
overall comfort.
Easy Installation
Factory-assembled package
is a
compact, fully self-contained, electric
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Other Manuals for Carrier 13 50XP
Summary
2 50XP cooling unit that is pre-wired, pre-piped, and pre-charged for minimum installation expense. 50XP units are available in a variety of standard cooling sizes with voltage options to meet residential and light commercial requirements. Units are light weight, and install easily on a rooftop or a...
3 50XP Model number nomenclature ARI* capacities COOLING CAPACITIES AND EFFICIENCIES 50XP 024 3 UNIT 50XP NOMINAL TONS STANDARD CFM NET COOLING CAPACITIES (Btuh) EER@A** SEER† SOUND RATINGS‡ (dB) 024 2 800 24,000 11.0 13.0 72 030 2-1/2 1000 28,800 11.0 13.0 72 036 3 1100 36,000 11.0 13.0 72 042 3-1/...
4 50XP OUTDOOR SOUND: OCTAVE BAND DATA—DECIBELS (Lw(A)) Physical data * Required fi lter sizes shown are based on the larger of the ARI (Air Conditioning & Refrigeration Institute) rated cooling air fl ow or the heating air fl ow velocity of 300 ft/min for throwaway type or 450 ft/min for high-c...