Form No. PDS CK5A.18.1

FURNACE N-COILS

CK5A, CK5B

Sizes A018 thru A060

This vertical design N-coil is a furnace coil designed to provide
the highest standards of reliability and durability. The product is
offered in a painted cased (CK5A) or an embossed cased
(CK5B) version. The cased coils are offered in standard, over-
hang, and wide configurations for use in multiple installation ap-
plications. Additionally, the cased coils are offered in a Transition
configuration, which is designed to fit two furnace widths without
field modification.

Easy maintenance is provided as the coil slides out of the cabi-
net after removing the access door and service panel.

The coils are available in sizes 018 through 060 (1-1/2-5 tons).

COMMON FEATURES

Water Management

—The CK coil design does an excellent job

of water management. The coils are designed to avoid water
blow-off into the ducts by directing condensate away from the
fins and into the drain pan. The coils drain pan design provides
improved condensate removal into the drain. This improves in-
door air quality.

Durable Condensate Pan

—Each coil is equipped with a corro-

sion resistant condensate drain pan. The condensate drain pan
is designed with a slope to help ensure proper drainage, im-
proved moisture removal, and home comfort.

Compact Design

—Unique design offers as much as 2 in. less

in height to aid in tight installations.

Brass Inserts

— Every condensate pan features two 3/4 in. fe-

male threaded brass insert connections. The Bryant unique
brass inserts provide for a leak-free condensate line connection
to prevent water damage.

Refrigerant Connections

—The coils are provided with proven

sweat-connections for leak-free operation maintaining system
reliability.

Burst Pressures

—These coils meet or exceed burst pressure

of 2100 psi which is at least three to five times the pressure they
will see in actual application.

External Piston Location

—Provides easy access to the piston

metering device, for quick installations and standard service pro-
cedures.

Liquid Line Bracket

—Holds the piston body in place for quick,

safe piston access without needing a back-up wrench.

Neoprene Ring

—The ring, installed inside the liquid line con-

nection, is the best option for preventing refrigerant leaks and fu-
ture service calls. Neoprene works with both Puron® and R-22
Refrigerant.

Protective Tube Sheets

—Protect the durable copper tubing

from being damaged during the manufacturing and installation
process.

Warranty

—All Bryant coils feature a 1-year limited warranty on

parts, with additional extended warranties available for the
system.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - MODEL NUMBER NOMENCLATURE; C—Coil

— 2 — MODEL NUMBER NOMENCLATURE C K 5 C—Coil K—Cased, N-Coil 5—Upflow/Downflow CERTIFICATION APPLIES ONLY WHEN USED WITH PROPER COMPONENTS AS LISTED WITH ARI A X A 018 018—1-1/2 Ton 024—2 Ton030—2-1/2 TonEtc. 014—14-3/16 in.017—17-1/2 in.021—21 in.024—24 1/2 in. A — StandardN — NarrowT — TransitionW...

Page 3 - NOTE: 1. Series designation is the 14th position of

— 3 — A97606 DIMENSIONS (In.) * In these models the coil can be removed from the casing and installed as an uncased coil without needing to field fabricate the coil enclosure to prevent air bypass. UNIT SERIES A B C D E F G SHIPPING WEIGHT (LB) CK5(A,B)XA018014* A 14-3/16 13-1/4 12-9/16 5 5/8 2-1/8 ...

Page 5 - Use formula

— 5 — GROSS COOLING CAPACITIES (MBH) Continued CFM — Cubic Ft per Minute EWB — Entering Wet Bulb (°F) LWB — Leaving Wet Bulb (°F) TC — Total Cooling Capacity 1000 Btuh SHC — Total Sensible Capacity 1000 Btuh BF — Bypass Factor MBH —1000 Btuh NOTES: 1. Contact manufacturer for cooling capacities at c...