1
Installation, Start--Up, and
Operating Instructions
GAPA
PERFECT AIR
T
PURIFIER
SIZES 1625 AND 2025
NOTE
: Read the entire instruction manual before starting the
install.
This symbol
→
indicates a change since the last issue.
TABLE OF CONTENTS
Page
INTRODUCTION
1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
HOW IT WORKS
1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SAFETY CONSIDERATIONS
1
. . . . . . . . . . . . . . . . . . . . . . . .
APPLICATION CONSIDERATIONS
2
. . . . . . . . . . . . . . . . . .
INSTALLATION
3--5
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
START--UP AND OPERATION
6
. . . . . . . . . . . . . . . . . . . . . . .
MAINTENANCE
6
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TROUBLESHOOTING
7
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SPECIFICATIONS AND DIMENSIONS
8
. . . . . . . . . . . . . . . .
WARRANTY
9
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
INTRODUCTION
Congratulations for selecting the Perfect Air
t
Purifier for your
home comfort system! The Perfect Air
t
Purifier is proven to
remove and kill airborne germs and allergens, including viruses,
bacteria, and mold spores. The Perfect Air
t
Purifier is a
cornerstone of Bryant’s Perfect Air
t
Solutions for providing
healthier, cleaner air in your home.
HOW IT WORKS
The Perfect Air
t
Purifier provides extremely high filtration
performance while killing captured contaminants, including
viruses, bacteria, and mold spores. The Perfect Air
t
Purifier
treats the entire air--stream through a state of the art, three--stage
process, exclusive to Bryant.
I n st a g e o n e , t h e p a r t i c l e s a r e e l e c t r i c a l l y c h a rg e d b y a
precision--point ionization array as they enter the Perfect Air
t
Purifier.
In stage two, the charged particles are electrically attracted to
the air purification cartridge, which is located within an electric
field.
In stage three, captured particles are killed by electrical current
flow and ion bombardment.
A06054
Fig. 1 -- GAPA Unit
SAFETY CONSIDERATIONS
I m p r o p e r i n s t a l l a t i o n , a d j u s t m e n t , a l t e r a t i o n , s e r v i c e ,
maintenance, or use can cause explosion, fire, electrical shock
or other conditions which may cause personal injury or property
damage. Consult a qualified installer, service agency, or your
d i s t r i b u t o r o r b r a n c h f o r i n f o r m a t i o n o r a s s i s t a n c e . T h e
qualified installer or agency must use factory authorized kits or
a c c e s s o r i e s w h e n m o d i f y i n g t h i s p r o d u c t . R e f e r t o t h e
individual instructions packaged with the kits or accessories
when installing.
Follow all safety codes. Wear safety glasses and work gloves.
Have fire extinguisher available. Read these instructions
thoroughly and follow all warning or cautions attached to the
unit. Consult local building codes and National Electrical Code
(NEC) for special requirements.
It is important to recognize safety information. This is the
safety--alert symbol
. When you see this symbol on the unit
and in instructions or manuals, be alert to the potential for
p e r s o n a l i n j u r y. U n d e r s t a n d t h e si g n a l wo r d s D A N G E R ,
WARNING, and CAUTION. These words are used with the
safety -- alert symbol. DANGER identifies the most serious
hazards which
will
result in severe personal injury or death.
WARNING signifies hazards which
could
result in personal
injury or death. CAUTION is used to identify unsafe practices
which
may
result in personal injury or product and property
damage. NOTE is used to highlight suggestions which
will
result in enhanced installation, reliability, or operation.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 APPLICATION CONSIDERATIONS The Perfect Air t Purifier is designed for use in the return air duct of a forced air heating, cooling, and ventilation system. M o d e l s G A PA A X B B 1 6 2 5 a n d G A PA A X B B 2 0 2 5 a r e specifically designed for use in systems with a forced air gas furnace. A...
3 INSTALLATION Step 6 — Check Perfect Air t Purifier Components CUT HAZARD Failure to follow this caution may result in personal injury.Sheet metal parts may have sharp edges or burrs. Use care and wear appropriate protective clothing and gloves when handling parts. CAUTION ! b. Carefully remove all...
4 Step 8 — Mount the Cabinet ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury or death.Before installing or servicing system, always turn off main power to system. There may be more than 1 disconnect switch. ! WARNING UNIT DAMAGE HAZARD Failure to follow this ca...