Bryant 677C--A - Manual

Bryant 677C--A

Bryant 677C--A – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
Page: / 36

Table of Contents:

  • Page 2 – INTRODUCTION; Step 1 — Check Equipment; except; Step 3 — Field Fabricate Ductwork
  • Page 5 – LARGE CURB; SMALL CURB; IMPORTANT; : Do not install large base pan HYBRID HEAT
  • Page 6 – Step 5 — Rig and Place Unit; PERSONAL INJURY OR PROPERTY DAMAGE; Inspection; UNIT FALLING HAZARD; WARNING; PROPERTY DAMAGE HAZARD; WARNING
  • Page 7 – Step 6 — Connect Condensate Drain; Step 7 — Install Flue Hood; NOTE; Step 8 — Install Gas Piping; NOTE
  • Page 8 – Step 9 — Install Duct Connections; Configuring Units for Downflow (Vertical) Discharge
  • Page 10 – Table 2 – Maximum Gas Flow Capacity*; Table 3 – Heating Inputs
  • Page 11 – Step 10 — Install Electrical Connections; UNIT COMPONENT DAMAGE HAZARD; CAUTION; ELECTRICAL SHOCK HAZARD; ELECTRICAL SHOCK HAZARD; Then; Control Voltage Connections
  • Page 12 – Balance Point Setting--Thermidistat or Hybrid
  • Page 13 – Step 1 — Check for Refrigerant Leaks; Heating Sequence of Operation; ments
  • Page 14 – Check Heating Control; UNIT DAMAGE HAZARD; Adjust Gas Input
  • Page 15 – Measure Manifold Pressure (Propane Units); Check Burner Flame
  • Page 16 – Rollout Switch; Checking Cooling Control Operation; Indoor Airflow and Airflow Adjustments
  • Page 17 – Gas Heating Fan Speed Set-up; Continuous Fan Operation; Table 6 – Color Coding for Indoor Fan Motor Leads
  • Page 27 – MAINTENANCE; Air Filter
  • Page 29 – Outdoor Fan; Electrical Controls and Wiring
  • Page 32 – HPS – High Pressure Switch; LEGEND; Accurater; Refrigerant System
  • Page 33 – TROUBLESHOOTING
  • Page 34 – Table 11 – Troubleshooting Guide -- Cooling or Heat Pump Heating Mode
Loading the manual

1

677C-- --A

PREFERRED

t

14 SEER SINGLE--PACKAGED HYBRID HEAT

r

DUAL FUEL SYSTEM WITH PURON

r

(R--410A) REFRIGERANT

SINGLE AND THREE PHASE

2--5 NOMINAL TONS (SIZES 24--60)

Installation Instructions

NOTE

:

Read the entire instruction manual before starting the

installation.

NOTE

:

Installer: Make sure the Owner’s Manual and Service

Instructions are left with the unit after installation.

TABLE OF CONTENTS

PAGE

SAFETY CONSIDERATIONS

1

. . . . . . . . . . . . . . . . . . . . . . . . .

INTRODUCTION

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

RECEIVING AND INSTALLATION

2--13

. . . . . . . . . . . . . . . . .

Check Equipment

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Identify Unit

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Inspect Shipment

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Provide Unit Support

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Roof Curb

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Slab Mount

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Field Fabricate Ductwork

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

Provide Clearances

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Rig and Place Unit

6

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Connect Condensate Drain

7

. . . . . . . . . . . . . . . . . . . . . . . . . . .

Install Flue Hood

7

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Install Gas Piping

7

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Install Duct Connections

8

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Configuring Units for Downflow (Vertical)

Discharge

8

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Install Electrical Connections

11

. . . . . . . . . . . . . . . . . . . . . . . .

High--Voltage Connections

11

. . . . . . . . . . . . . . . . . . . . . . . .

Special Procedures for 208--V Operation

11

. . . . . . . . . . . . . .

Control Voltage Connections

11

. . . . . . . . . . . . . . . . . . . . . . .

Balance Point Setting Thermidistat or Hybrid Heat

Thermostat

12

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Transformer Protection

12

. . . . . . . . . . . . . . . . . . . . . . . . . . .

PRE--START--UP

12

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

START--UP

13--17

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Check for Refrigerant Leaks

13

. . . . . . . . . . . . . . . . . . . . . . . . .

Unit Sequence of Operation

13

. . . . . . . . . . . . . . . . . . . . . . . . .

Start--Up Heating and Make Adjustments

13

. . . . . . . . . . . . . . .

Checking Heating Control

14

. . . . . . . . . . . . . . . . . . . . . . . . .

Check Gas Input

14

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Adjust Gas Input

14

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Check Burner Flame

15

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Start--Up Cooling and Make Adjustments

16

. . . . . . . . . . . . . . .

Checking Cooling Control Operation

16

. . . . . . . . . . . . . . . .

Checking and Adjusting Refrigerant

16

. . . . . . . . . . . . . . . . .

Indoor Airflow and Airflow Adjustments

16

. . . . . . . . . . . . .

Continuous Fan Operation

17

. . . . . . . . . . . . . . . . . . . . . . . .

MAINTENANCE

27--33

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Air Filter

27

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Indoor Blower and Motor

27

. . . . . . . . . . . . . . . . . . . . . . . . . . .

Flue Gas Passageways

28

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Limit Switch

28

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Burner Ignition

28

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Main Burners

28

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Outdoor Coil, Indoor Coil, & Condensate Drain Pan

28

. . . . . .

A09042

Fig. 1 -- Unit 677C-- --A

Outdoor Fan

29

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Electrical Controls and Wiring

29

. . . . . . . . . . . . . . . . . . . . . . .

Refrigerant Circuit

29

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Gas Input

29

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Indoor Airflow

29

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Check Defrost Thermostat

29

. . . . . . . . . . . . . . . . . . . . . . . . . . .

Puron

R

Items

29

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TROUBLESHOOTING

32

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

START--UP CHECKLIST

32

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

SAFETY CONSIDERATIONS

Improper installation, adjustment, alteration, service maintenance,

or use can cause explosion, fire, electrical shock, or other

conditions which may cause death, personal injury, or property
damage. Consult a qualified installer, service agency, or your

distributor or branch for information or assistance. The qualified
installer or agency must use factory--authorized kits or accessories

when modifying this product. Refer to the individual instructions

packaged with the kits or accessories when installing.
Follow all safety codes. Wear safety glasses, protective clothing,

and work gloves. Have a fire extinguisher available. Read these
instructions thoroughly and follow all warnings or cautions

included in literature and attached to the unit. consult local

building codes, the current editions of the National Fuel Gas Code
(NFGC) NFPA 54/ANSI Z223.1, and the National Electrical Code

(NEC) NFPA 70.
In Canada refer to the current editions of the National Standards of

Canada CAN/CSA--B149.1 and .2 Natural Gas and Propane
Installation codes, and Canadian Electrical Code CSA C22.1

Recognize safety information. This is the safety--alert symbol

.

When you see this symbol on the unit and in instructions or manu-

als, be alert to the potential for personal injury. Understand these

signal words: DANGER, WARNING, and CAUTION. These
words are used with the safety--alert symbol. DANGER identifies

the most serious hazards which

will

result in severe personal injury

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - INTRODUCTION; Step 1 — Check Equipment; except; Step 3 — Field Fabricate Ductwork

2 or death. WARNING signifies hazards which could result in per- sonal injury or death. CAUTION is used to identify unsafe practic- es which may result in minor personal injury or product and prop- erty damage. NOTE is used to highlight suggestions which will result in enhanced installation, reliabi...

Page 5 - LARGE CURB; SMALL CURB; IMPORTANT; : Do not install large base pan HYBRID HEAT

5 C B A F D E LARGE CURB C B A F D E SMALL CURB ROOF CURB DETAIL Wood nailer* Roofcurb* Insulation(field supplied) *Provided with roofcurb Cant stripfield supplied Roofing materialfield supplied Flashing fieldsupplied HVAC unitbase rails Roofcurb SealingGasket HVAC unitbasepan Anchor screw A09090 A0...

Page 6 - Step 5 — Rig and Place Unit; PERSONAL INJURY OR PROPERTY DAMAGE; Inspection; UNIT FALLING HAZARD; WARNING; PROPERTY DAMAGE HAZARD; WARNING

6 ACCESS PANELS MUST BE IN PLACE WHEN RIGGING. PANNEAUX D'ACCES DOIT ÊTRE EN PLACE POUR MANIPULATION. 50CY502286 2.0 CAUTION - NOTICE TO RIGGERSPRUDENCE - AVIS AUX MANIPULATEUR Use top skid as spreader bar. / Utiliser la palette du haut comme barre de répartition SEAL STRIP MUST BE INPLACE BEFORE PL...

Other Bryant Models

All Bryant Other