Bryant 581C - Manual

Bryant 581C

Bryant 581C – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
61 Page 61
62 Page 62
63 Page 63
64 Page 64
65 Page 65
66 Page 66
67 Page 67
68 Page 68
69 Page 69
70 Page 70
71 Page 71
72 Page 72
73 Page 73
74 Page 74
75 Page 75
76 Page 76
77 Page 77
78 Page 78
79 Page 79
80 Page 80
81 Page 81
82 Page 82
83 Page 83
84 Page 84
85 Page 85
86 Page 86
87 Page 87
88 Page 88
89 Page 89
90 Page 90
91 Page 91
92 Page 92
93 Page 93
94 Page 94
95 Page 95
96 Page 96
97 Page 97
98 Page 98
99 Page 99
100 Page 100
101 Page 101
102 Page 102
103 Page 103
104 Page 104
105 Page 105
106 Page 106
107 Page 107
108 Page 108
109 Page 109
110 Page 110
111 Page 111
112 Page 112
113 Page 113
114 Page 114
115 Page 115
116 Page 116
117 Page 117
118 Page 118
119 Page 119
120 Page 120
121 Page 121
122 Page 122
123 Page 123
124 Page 124
125 Page 125
126 Page 126
127 Page 127
128 Page 128
129 Page 129
130 Page 130
131 Page 131
132 Page 132
133 Page 133
134 Page 134
135 Page 135
136 Page 136
137 Page 137
138 Page 138
139 Page 139
140 Page 140
141 Page 141
142 Page 142
143 Page 143
144 Page 144
145 Page 145
146 Page 146
147 Page 147
148 Page 148
149 Page 149
150 Page 150
151 Page 151
152 Page 152
153 Page 153
154 Page 154
155 Page 155
156 Page 156
157 Page 157
158 Page 158
159 Page 159
160 Page 160
161 Page 161
162 Page 162
163 Page 163
164 Page 164
165 Page 165
166 Page 166
167 Page 167
168 Page 168
169 Page 169
170 Page 170
171 Page 171
172 Page 172
173 Page 173
174 Page 174
175 Page 175
176 Page 176
177 Page 177
178 Page 178
179 Page 179
180 Page 180
181 Page 181
182 Page 182
183 Page 183
184 Page 184
185 Page 185
186 Page 186
187 Page 187
188 Page 188
189 Page 189
190 Page 190
191 Page 191
192 Page 192
193 Page 193
194 Page 194
195 Page 195
196 Page 196
197 Page 197
198 Page 198
199 Page 199
200 Page 200
201 Page 201
202 Page 202
203 Page 203
204 Page 204
205 Page 205
206 Page 206
207 Page 207
208 Page 208
209 Page 209
210 Page 210
211 Page 211
212 Page 212
213 Page 213
214 Page 214
215 Page 215
216 Page 216
217 Page 217
218 Page 218
219 Page 219
220 Page 220
221 Page 221
222 Page 222
223 Page 223
224 Page 224
225 Page 225
226 Page 226
227 Page 227
228 Page 228
229 Page 229
230 Page 230
231 Page 231
232 Page 232
233 Page 233
234 Page 234
235 Page 235
236 Page 236
237 Page 237
238 Page 238
239 Page 239
240 Page 240
241 Page 241
242 Page 242
243 Page 243
244 Page 244
245 Page 245
246 Page 246
247 Page 247
248 Page 248
249 Page 249
250 Page 250
251 Page 251
252 Page 252
253 Page 253
254 Page 254
255 Page 255
256 Page 256
257 Page 257
258 Page 258
259 Page 259
260 Page 260
261 Page 261
262 Page 262
263 Page 263
264 Page 264
265 Page 265
266 Page 266
267 Page 267
268 Page 268
269 Page 269
270 Page 270
271 Page 271
272 Page 272
273 Page 273
274 Page 274
275 Page 275
276 Page 276
277 Page 277
278 Page 278
279 Page 279
280 Page 280
281 Page 281
282 Page 282
283 Page 283
284 Page 284
285 Page 285
286 Page 286
287 Page 287
288 Page 288
289 Page 289
290 Page 290
291 Page 291
292 Page 292
293 Page 293
294 Page 294
295 Page 295
296 Page 296
297 Page 297
298 Page 298
Page: / 298

Table of Contents:

  • Page 2 – TABLE OF CONTENTS; Page; DURABLE, DEPENDABLE CONSTRUCTION —; Designed for
  • Page 8 – MODEL NUMBER NOMENCLATURE; Design Series Code
  • Page 9 – contact application engineering.; Natural Gas/Electric Relight Pilot; Design Series Change
  • Page 11 – Annual Fuel Utilization Efficiency
  • Page 20 – OPTIONS AND ACCESSORIES; accessory and option package information.
  • Page 28 – ASHRAE 90.1 COMPLIANT UNITS
  • Page 29 – 80F — OPTION/ACCESSORY WEIGHTS
  • Page 34 – ACCESSORY DIMENSIONS — 580F; Roof Curb
  • Page 35 – Roof Curb Details
  • Page 36 – SELECTION PROCEDURE (with 580F060 example)
  • Page 37 – PERFORMANCE DATA; COOLING CAPACITIES
  • Page 41 – FAN PERFORMANCE — VERTICAL DISCHARGE UNITS
  • Page 42 – FAN PERFORMANCE — VERTICAL DISCHARGE UNITS (cont)
  • Page 54 – Refer to page 74 for general Fan Performance Data notes.
  • Page 59 – FAN PERFORMANCE — HORIZONTAL DISCHARGE UNITS
  • Page 60 – FAN PERFORMANCE — HORIZONTAL DISCHARGE UNITS (cont)
  • Page 61 – Bhp; Brake Horsepower Input to Fan; Watts —; Input Watts to Motor
  • Page 74 – GENERAL NOTES FOR FAN PERFORMANCE DATA TABLES
  • Page 76 – POWER EXHAUST OPTIONS; All
  • Page 77 – The EPACT (Energy Policy Act of 1992) regulates energy
  • Page 78 – EVAPORATOR-FAN MOTOR PERFORMANCE
  • Page 79 – ELECTRICAL DATA; POWER EXHAUST ELECTRICAL DATA
  • Page 84 – RUN
  • Page 85 – RED; Use copper conductors only.
  • Page 86 – NEC —; National Electrical Code
  • Page 88 – Bhp —
  • Page 90 – 81B — OPTION/ACCESSORY WEIGHTS
  • Page 95 – SELECTION PROCEDURE (With 581B048 Example); Unit ratings are gross capacities and do not
  • Page 96 – COOLING CAPACITIES, STANDARD UNITS
  • Page 107 – Refer to this page for general Fan Performance Data notes.
  • Page 108 – Refer to page 107 for general Fan Performance Data notes.
  • Page 119 – See page 107 for general fan performance notes.
  • Page 131 – †Orifices are available through your local Bryant distributor.; ALTITUDE DERATING FACTOR*; Local utility companies may be reducing heat content of gas
  • Page 132 – EVAPORATOR-FAN MOTOR EFFICIENCY; Convert bhp to watts using the following formula:; SOUND; motor efficiency
  • Page 133 – VERTICAL POWER EXHAUST PERFORMANCE
  • Page 136 – Maximum Overcurrent Protection
  • Page 139 – TYPICAL WIRING SCHEMATICS — 581B
  • Page 143 – ENERGY STAR QUALIFIED
  • Page 145 – not
  • Page 146 – both
  • Page 149 – Cleanable Screen quantity and size varies with option selected.
  • Page 151 – PERFORMANCE DATA — 581C
  • Page 161 – FAN RPM AT MOTOR PULLEY SETTING WITH STANDARD MOTOR* — 581C024-060
  • Page 162 – EVAPORATOR-FAN MOTOR EFFICIENCY —
  • Page 163 – STANDARD UNIT; , the unit will require a; PERFECT HUMIDITYTM ADAPTIVE DEHUMIDIFICATION COIL PRESSURE DROP
  • Page 164 – Power Exhaust System; VERTICAL ECONOMI$ER IV AND ECONOMI$ER2
  • Page 165 – SOUND DATA; ARI; Air Conditioning and Refrigeration Institute
  • Page 167 – TYPICAL WIRING SCHEMATICS — 581C
  • Page 168 – OAT —; Outdoor Air Temperature Sensor
  • Page 169 – NEC — National Electrical Code; HORIZONTAL DISCHARGE DUCTING
  • Page 176 – OPERATING AND RIGGING WEIGHTS
  • Page 180 – CRRFCURB013A00 is a fully factory preassembled horizontal; ACCESSORY; Horizontal Adapter; Barometric Relief/Power Exhaust
  • Page 181 – Factory-Installed Convenience Outlet; Knockout
  • Page 182 – SELECTION PROCEDURE (With 579F180 Example)
  • Page 183 – PERFORMANCE DATA — 579F
  • Page 194 – ALTITUDE COMPENSATION* —; †Orifices available through your Bryant distributor.; Local utility companies may be reducing heat content of; ELEVATION
  • Page 195 – †Indicates standard drive package.
  • Page 196 – All indoor-fan motors 5 hp and larger meet the minimum effi-
  • Page 198 – TYPICAL WIRING SCHEMATICS — 579F
  • Page 199 – LEGEND AND NOTES
  • Page 212 – SELECTION PROCEDURE (With 580F240 Example)
  • Page 221 – †Orifices available through your Bryant dealer.; OUTDOOR SOUND POWER; Indoor sound power is available in Bryant’s Electronic Catalog; Fan Performance Using Accessory
  • Page 222 – FAN RPM AT MOTOR PULLEY SETTINGS*
  • Page 224 – TYPICAL WIRING SCHEMATICS — 580F
  • Page 231 – OPERATING AND RIGGING WEIGHTS — 581A155,180; Copper
  • Page 235 – Adapter Roof Curb
  • Page 238 – SELECTION PROCEDURE
  • Page 239 – COOLING CAPACITIES — STANDARD UNITS
  • Page 240 – COOLING CAPACITIES — STANDARD UNITS (cont)
  • Page 244 – COOLING CAPACITIES, UNITS WITH HOT GAS REHEAT OPTION
  • Page 249 – Refer to page 262 for general Fan Performance Data notes.; Watts
  • Page 251 – using Bryant horizontal adapter curb.
  • Page 253 – All other rpms require field-supplied drive.
  • Page 271 – All indoor-fan motors 5 hp and larger meet the minimum efficiency
  • Page 277 – ELECTRICAL DATA — 581A210-300 WITH OPTIONAL CONVENIENCE OUTLET
  • Page 278 – TYPICAL WIRING SCHEMATICS — 581A
  • Page 289 – CONTROLS; Heating, Units Without Economizer —
  • Page 291 – Units With Hot Gas Bypass Dehumidification Package —; When thermostat calls; Heating, Units Without Economizer; When free cooling is
  • Page 292 – Heating, Units With Economizer
  • Page 293 – APPLICATION DATA; will not
  • Page 294 – E-COATED ALUMINUM FIN; coils undergo a precisely; THERMOSTAT INTERFACE —; CONCENTRIC DUCT DISTRIBUTION; Do not drill in this area, damage to basepan may result in; Shaded area indicates block-off panels.; Concentric Duct Details
  • Page 296 – ECONOMI$ER IV SENSOR USAGE CHART; †CGCDXSEN004A00 is an accessory CO; Economizer Changeover Curves; APPROXIMATE DRY BULB TEMPERATURE— °F (°C)
Loading the manual

Form No. PDS580F-36-4

COMMERCIAL
SINGLE PACKAGE ROOFTOP UNITS
GAS HEATING/ELECTRIC COOLING UNITS

Standard efficiency units (580F072, 090, 120, 150 and
579F180-300) are available. Standard efficiency units
(580F036-060, 073, 091,103,121,151, and 180-300) that meet
ASHRAE 90.1-04 minimum energy efficiency requirements are
also available. High efficiency units (581C024-060, 581B036-
150 and 581A155-300) well exceed ASHRAE 90.1-04 energy
efficiency requirements and must comply with Energy Star high
efficiency requirements. Gas heating with electric cooling roof-
tops offer:

• Pre-painted galvanized steel cabinet for long life and quality

appearance

• Commercial strength base rails with built-in rigging capability
• Convertible design for vertical or horizontal supply/return

(024-151 field convertible, factory supplied vertical supply/
return and 210-300 discrete configuration only)

• Non-corrosive, sloped condensate drain pan, meets

ASHRAE 62 (IAQ)

• Two-inch return-air filters
• A wide assortment of factory-installed options available,

including high-static drives that provide additional perfor-
mance range

• Factory-installed optional gear driven EconoMi$er IV (vertical

return for sizes 024-151 only) for use with standard rooftop
unit controls (includes CO

2

sensor control capability)

• Factory-installed optional gear driven EconoMi$er2 (vertical

return only) for use with third party DDC controls (includes
4 to 20 mA actuator for demand control ventilation)

• Perfect Humidity™ dehumidification package (581C036-060

and 581B036-150 only)

• Hot gas reheat dehumidification package (581A181-300 only)

Heat Options

• Exclusive integrated gas control board with diagnostics
• Alumagard™ heat exchanger coating

• Induced-draft fan for gas combustion
• Tubular, dimpled heat exchangers
• Natural gas
• LP conversion kits
• Low NO

X

(size 024-060 only)

• Optional type 409 stainless steel heat exchangers.

FEATURES/BENEFITS

Every compact one-piece unit arrives fully assembled,
charged, tested, and ready to run.

GAS HEAT MODELS

— All ignition components are contained

in the compact IGC (integrated gas controller) which is easily
accessible for servicing. The IGC control board, designed and
manufactured exclusively for Bryant rooftop units, provides
built-in diagnostic capability. An LED (light-emitting diode) sim-
plifies troubleshooting by providing visual fault notification and
required system status confirmation.

The IGC also contains an exclusive anti-cycle protection for
gas heat operation. After 4 continuous cycles on the unit high-
temperature limit switch, the gas heat operation is disabled,
and an error code is issued. This feature greatly improves reli-
ability of the rooftop unit.

The IGC also contains burner control logic for accurate and
dependable gas ignition. The LED is visible without removing
the unit control box access panel. This LED fault-notification
system reduces service person troubleshooting time and mini-
mizes service costs. The IGC also maximizes heating effi-
ciency by controlling evaporator-fan on and off delays.

Tubular, dimpled gas heat exchangers optimize heat transfer
for improved efficiency. The tubular design permits hot gases
to make multiple passes across the path of the supply air. The
dimpled design creates a turbulent gas flow to maximize heat-
ing efficiency.

580F, 579F, 581A/B/C

DuraPac and

DuraPac Plus Series

Sizes 024-300

2 to 25 Tons

SIZES 024-073

SIZES 090-151

579F180-216

581A155,180

580F180,210

580F240
579F240-300

580F300

581A210-300

48-910df

a48-8207

50-1242f

50-1214df

a48-5997

48-831df

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - TABLE OF CONTENTS; Page; DURABLE, DEPENDABLE CONSTRUCTION —; Designed for

2 TABLE OF CONTENTS Page Features/Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4Model Number Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . 5-9ARI Capacity Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-19Options and Accessories . . ....

Page 8 - MODEL NUMBER NOMENCLATURE; Design Series Code

8 MODEL NUMBER NOMENCLATURE — 579F180-300 MODEL NUMBER NOMENCLATURE 580F180-300 NOTES: 1. All indoor-fan motors 5 hp and larger meet the minimum efficiency requirements as established by the Energy Policy Act of 1992 (EPACT) effective October 24, 1997. 2. The example model number 579FEV180230--CB de...

Page 9 - contact application engineering.; Natural Gas/Electric Relight Pilot; Design Series Change

9 MODEL NUMBER NOMENCLATURE 581A155, 180, 181 — 13 to 15 Tons MODEL NUMBER NOMENCLATURE 581A210-300 — 18 to 25 Tons *See pages 212 and 213 for cooling capacity tables for 581A181 unit. For all other data, contact application engineering. NOTE: All indoor-fan motors 5 hp and larger meet the minimum e...

Other Bryant Models

All Bryant Other