Bryant 580J***(D - Manual

Bryant 580J***(D

Bryant 580J***(D – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
Page: / 8

Table of Contents:

  • Page 2 – Standard Warranty; SUBMITTAL DATA; Cooling; ELECTRICAL DATA
  • Page 3 – OPTIONS AND ACCESSORIES; OPTIONAL WARRANTIES; Commercial Start--Up and Optional Extended; FIELD INSTALLED ACCESSORIES; Economizer Sensors
  • Page 8 – ROOF CURB DETAILS
Loading the manual

580J***(D,F)

SINGLE PACKAGE ROOFTOP

GAS HEATING/ELECTRIC COOLING UNIT

TWO STAGE COOLING CAPACITY CONTROL WITH NOVATION

t

COIL

SIZES 08, 12, 14 WITH PURON

R

(R--410A) REFRIGERANT

Submittal Data

®

This product has been designed and manufactured

to meet Energy Star

®

criteria for energy efficiency.

However, proper refrigerant charge and proper air

flow are critical to achieve rated capacity and effi-

ciency. Installation of this product should follow all

manufacturer’s refrigerant charging and air flow in-

structions.

Failure to confirm proper charge and

air flow may reduce energy efficiency and short-

en equipment life.

DESCRIPTION

580J***(D,F) units are high--efficiency, single--packaged

electric cooling, gas heating units that are pre--wired and

pre--charged with Puron

R

(R--410A) HFC refrigerant.

Units utilize an all aluminum flat micro--channel tube

with louvered fins condenser coil—NOVATION

t

. The

units are factory tested in both heating and cooling modes.

These units meet the ASHRAE 90.1--2007 and Energy

Star minimum efficiency levels as well as also meeting

2010 efficiency standards.

STANDARD FEATURES

Base Unit

S

Puron (R--410A) HFC refrigerant

S

ARI certified efficiency levels up to 11.1 EER

S

Rated in accordance with ARI Standard 360

S

Designed in accordance with Underwriters’ Laboratories Std
1995 and listed by UL and UL, Canada

S

Two--stage cooling capacity control

S

Non--corrosive composite sloping design; side or center drain
condensate pan. Meets ASHRAE Standard 62

S

Standard cooling operating range from 40

_

F up to 115

_

F

(4

_

C up to 46

_

C). Field installable accessory extends the

minimum down to --20

_

F (--29

_

C).

S

Convertible from vertical to horizontal airflow for slab mounting

S

Two--inch disposable return air filters

S

Thru--the--bottom power and gas entry capability

S

Single point gas and electric connections

S

24--volt control circuit protected with resettable circuit breaker
and 75--VA transformer

S

Belt drive, constant torque, permanently lubricated
evaporator–fan motor

S

Totally enclosed condenser motors with permanently lubricated
bearings

S

Low--pressure and high--pressure switches

S

Full perimeter base rail with built--in rigging adapters and fork
truck slots

S

Centralized Terminal Board for component and unit wiring
connections

Cabinet

S

Access panels with easy grip handles and NO--STRIP screw
collar

S

Pre--painted exterior panels and primer--coated interior panels
tested to 500 hours salt spray protection

S

Fully insulated cabinet

S

Tool--less filter access door

Refrigerant System

S

Acutrol

t

refrigerant metering system

S

Liquid line filter drier

S

Scroll compressors with internal line--break overload protection

S

Copper

tube

, aluminum fin evaporator coil

S

NOVATION all aluminum condenser coil

S

Removable gauge line plugs for reading refrigerant pressure
with unit panels in place

Gas Heat

S

IGC solid--state gas heat exchanger control for on--board
diagnostics, anti--cycle protection, LED error code designation,
burner control logic and energy saving indoor fan motor delay

S

Gas efficiencies up to 82%

S

Designed in accordance with ANSI Z21.47 (design and test
standard for gas furnaces) and ANSI Z233.1 (National Fuel Gas
code relating to appliance installation requirements)

S

Induced draft combustion

S

Redundant gas valve, with up to 2 stages of heating

S

Flame roll--out safety protector

S

Solid--state electronic direct spark ignition system

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Standard Warranty; SUBMITTAL DATA; Cooling; ELECTRICAL DATA

2 STANDARD FEATURES (cont.) Standard Warranty S 15--year gas heat exchanger -- Stainless Steel S 10--year gas heat exchanger -- Aluminized S 5--year compressor S 3--year NOVATION condenser coil S 1--year parts SUBMITTAL DATA Job Name Architect Engineer Contractor Unit Designation PERFORMANCE DATA Un...

Page 3 - OPTIONS AND ACCESSORIES; OPTIONAL WARRANTIES; Commercial Start--Up and Optional Extended; FIELD INSTALLED ACCESSORIES; Economizer Sensors

3 OPTIONS AND ACCESSORIES FACTORY--INSTALLED OPTIONS (FIOPs) j Open protocol RTU--MP controller communicates to LON, MODBUS, BACNET and Johnson N2 protocols. j Through the base connectors for gas and electric conduit/piping j Stainless steel gas heat exchanger (includes tubes, vestibule plate and co...

Page 8 - ROOF CURB DETAILS

8 ROOF CURB DETAILS 580J*08, 580J*08, 12, 12, 14(D,F) 14(D,F) ROOFCURB ACCESSORY CRRFCURB003A01 CRRFCURB004A01 1’ - 2” (356)2’ - 0” (610) UNIT SIZE UNIT SIZE C08547 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring o...

Other Bryant Models