580J*16D

SINGLE PACKAGE ROOFTOP, GAS HEATING/ELECTRIC COOLING UNIT
WITH PURON

R

(R--410A) REFRIGERANT

SIZE: 16

Electrical Data Supplement

NOTE

: Read the entire instruction manual before starting the installation

This supplement only applies to 580J size 16 units when the 13

th

digit of the Model Number is a “3”, as

shown in the Model Number Nomenclature diagram below. Check the Unit Nameplate (see Figs. 1 & 2). If

the digit in the 13

th

position is not a “3” discard this document.

MODEL NUMBER NOMENCLATURE

5

8

0

J

E

1

6

D

2

4

0

A

3

A

0

A

A

Model

580J = Gas Heating Rooftop Unit

Cooling Tons

16 = 15 ton

1

2

3

4

5

6

7

8

9

10 11 12

13

14 15 16 17

Coil Options For Round Tube/Plate Fin Condenser Coil Models Only
(Outdoor – Indoor – Hail Guard)

A = Al/Cu – Al/Cu
B = Precoat Al/Cu – Al/Cu
C = E-coat Al/Cu – Al/Cu
D = E-coat Al/Cu – E-Coat Al/Cu
E = Cu/Cu – Al/Cu
F = Cu/Cu – Cu/Cu
M = Al/Cu – Al/Cu – Louvered Hail Guards
N = Precoat Al/Cu – Al/Cu – Louvered Hail Guards
P = E-coat Al/Cu – Al/Cu – Louvered Hail Guards
Q = E-coat Al/Cu – E-coat Al/Cu – Louvered Hail Guards
R = Cu/Cu – Al/Cu – Louvered Hail Guards
S = Cu/Cu – Cu/Cu – Louvered Hail Guards

Coil Options For All Aluminum-Novation Condenser Coil Models Only
(Outdoor – Indoor – Hail Guard)

G = Al/Al – Al/Cu
H = Al/Al – Cu/Cu
J = Al/Al – E-coat Al/Cu
K = E-coat Al/Al – Al/Cu
L = E-coat Al/Al – E-coat Al/Cu
T = Al/Al – Al/Cu – Louvered Hail Guards
U = Al/Al – Cu/Cu – Louvered Hail Guards
V = Al/Al – E-coat Al/Cu – Louvered Hail Guards
W = E-coat Al/Al – Al/Cu – Louvered Hail Guards
X = E-coat Al/Al – E-coat Al/Cu – Louvered Hail Guards

Voltage

E = 460-3-60
P = 208/230-3-60
T = 575-3-60

Refirg. System/Gas Heat Options

A = Standard One Stage Cooling Models/Natural Gas Heat
B = Standard One Stage Cooling Models/Low NOx Heat
C = Standard One Stage Cooling Models/SS HX Heat
D = Two Stage Cooling Models
F = Two Stage Cooling Models and
Stainless Steel Gas Heat Exchanger

Heat Level

Standard/Stainless Steel
072 = 72,000

224 = 224,000

115 = 115,000

240 = 240,000

150 = 150,000

250 = 250,000

180 = 180,000

350 = 350,000

Low Nox
060 = 60,000
090 = 90,000
120 = 120,000

Indoor Fan Options

1 = Standard Static Option
2 = Medium Static Option
3 = High Static Option

C11016