580F units are a single piece, gas heating/electric
cooling unit, with a low profile, pre-wired, tested
and charged at the factory. The units have the
capability for convertible supply and return open-
ings and are intended for installation on an acces-
sory curb (ordered separately), or for slab mounting
(for horizontal duct connections). Units are
designed to accept a field-installed economizer,
enthalpy control, manual or 2-position outside air
damper, roof curb, as well as up to 3 choices of gas
heat. Refer to accessory chart for full listing.
FEATURES
• Standard one-year full product warranty.
• Five-year protection plan for the motor-
compressor.
• Five-year protection plan on heat exchangers.
• Outdoor ambient cooling operation from 25 F
(–4 C) to 115 F (46 C).
• Units are tested and cer tified by ARI and certi-
fied by UL and CSA. Factory-run test printout
included in each rooftop.
• 24-volt control circuit, with resettable breaker.
• Two-inch disposable-type return air filters in ded-
icated rack.
• Hermetic compressor on independent circuit with
internal line break and overload protection, self-
lubricating with internal discharge muffler.
• Refrigeration circuit contains a filter drier to trap
dirt and par ticles.
• Two-speed direct-drive evaporator fan on
sizes 036-060. All other sizes are belt driven.
Adjustable belt-drive fans are optional on 036-
060 sizes.
• Non-corrosive condensate pan with self-draining
design with both bottom and side drain
connections.
• Thru-the-bottom power, control and gas entry
capability.
• Indoor and outdoor coils constructed of alumi-
num fins mechanically bonded to seamless
copper tubes.
• Single point electrical and gas connections.
• Direct-drive propeller condenser fan totally
enclosed with permanently lubricated bearings.
• Pre-painted, insulated cabinet with primed inner
panels, cer tified 500-hr salt spray test and non-
corrosive screws.
• Large, easily removable panels provide ready
access to unit components for rapid removal or
maintenance.
SUBMITTAL DATA
Job Name ______________________________________
Architect _______________________________________
Engineer _______________________________________
Contractor
_____________________________________
Unit Designation _________________________________
PERFORMANCE DATA
Cooling
Net Total Cap. ________________________________ Btuh
Net Sensible Cap. _____________________________ Btuh
Compressor Power Input _________________________ kW
_______________________________ F Outdoor Air Temp.
Indoor Entering Air db _________ F
wb _________ F
CFM ____________
Ext. Static Pressure ____ (in. wg)
Fan RPM ____________________________________ Bhp
SEER/EER______________________________________
Heating
Input:
Stage 1 ______________ Total ___________ Btuh
Output: Stage 1 ______________ Total ___________ Btuh
AFUE _________________________________________ %
Steady State ___________________________________ %
Operating Weight ________ lbs. (unit) _______ lbs. (curb)
ELECTRICAL DATA
Power Supply to Unit ______ Volts _____ Phase _____ Hz
Minimum Circuit Amps ______________
Maximum Overcurrent Protection (Fuse Only) ___________
HEATING & COOLING SUBMITTAL
Dura
Pac
Series
Unit 580F036-150
3 to 12
1
/
2
NOMINAL TONS
COMMERCIAL SINGLE-PACKAGE
ROOFTOP GAS HEATING/
ELECTRIC COOLING UNITS