Bryant 577D----A - Manual
Bryant 577D----A – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – SAFETY CONSIDERATIONS; WARNING; INTRODUCTION; Check Equipment
- Page 3 – Installation on older “G” series roof curbs.; CAUTION; except; Provide Clearances; IMPORTANT; Rig and Place Unit; Inspection; UNIT FALLING HAZARD; PROPERTY DAMAGE HAZARD
- Page 9 – DETAIL A; Select and Install Ductwork; PERSONAL INJURY HAZARD
- Page 10 – Configuring Units for Downflow (Vertical) Discharge; Horizontal Duct Covers; Provide for Condensate Disposal
- Page 11 – Install Flue Hood; CARBON MONOXIDE POISONING HAZARD; Install Gas Piping; NOTE
- Page 12 – Install Electrical Connections; ELECTRICAL SHOCK HAZARD
- Page 13 – Table 2 – Maximum Gas Flow Capacity*; EQUIPMENT OPERATION HAZARD
- Page 15 – FURNACE BOARD
- Page 23 – Sequence of Operation
- Page 26 – FIRE AND UNIT DAMAGE HAZARD
- Page 28 – Check for Refrigerant Leaks
- Page 29 – Table 6 – Heating Input
- Page 31 – MAINTENANCE
- Page 32 – Inducer Pressure Switch; Outdoor Coil, Indoor Coil, and Condensate; UNIT OPERATION HAZARD; Electrical Controls and Wiring
- Page 33 – Refrigerant Circuit; Refrigerant System
- Page 34 – TROUBLESHOOTING
- Page 35 – FINAL CHECKS
- Page 36 – CARE AND MAINTENANCE; areas, such as coastal applications. See Users Manual for
- Page 37 – Never
- Page 38 – Table 9 – Troubleshooting Chart -- Cooling
- Page 39 – Table 10 – Troubleshooting Chart -- Gas Furnace Operation
1
577D-- --A
EVOLUTION
R
15 SEER SINGLE--PACKAGED AIR CONDITIONER AND GAS FURNACE
SYSTEM WITH PURON
R
(R--410A) REFRIGERANT
SINGLE PHASE
2--5 NOMINAL TONS (SIZES 24--60)
Installation Instructions
EQUIPMENT OPERATION HAZARD
Failure to follow this caution may result in improper unit
operation.
OAT sensor must be field installed. See Accessory
Installation for more details.
CAUTION
!
EQUIPMENT OPERATION HAZARD
Failure to follow this caution may result in improper unit
operation.
This Evolution
r
unit is designed for use with an Evolution
User Interface.
CAUTION
!
NOTE
:
Read the entire instruction manual before starting the
installation.
TABLE OF CONTENTS
PAGE
SAFETY CONSIDERATIONS
2
. . . . . . . . . . . . . . . . . . . . . . . . .
INTRODUCTION
2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RECEIVING AND INSTALLATION
2--13
. . . . . . . . . . . . . . . . .
Check Equipment
2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Identify Unit
2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Inspect Shipment
2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Provide Unit Support
2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Roof Curb
2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Slab Mount
3
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Provide Clearances
3
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Rig and Place Unit
3
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Inspection
3
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Rigging/Lifting of Unit
9
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Select and Install Ductwork
9
. . . . . . . . . . . . . . . . . . . . . . . . . . .
Configuring Units for Downflow (Vertical) Discharge
10
. . .
Provide for Condensate Disposal
10
. . . . . . . . . . . . . . . . . . . . .
Install Flue Hood
11
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Install Gas Piping
11
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Install Electrical Connections
12
. . . . . . . . . . . . . . . . . . . . . . . .
High--Voltage Connections
12
. . . . . . . . . . . . . . . . . . . . . . . .
Routing Power Leads Into Unit
12
. . . . . . . . . . . . . . . . . . . . .
Connecting Ground Lead to Ground Screw
12
. . . . . . . . . . .
Routing Control Power Wires
13
. . . . . . . . . . . . . . . . . . . . .
Accessory Installation
13
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Special Procedures for 208--v Operation
13
. . . . . . . . . . . . . .
PRE--START--UP
16
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
START--UP
16--29
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Unit Start--Up and Troubleshooting
16
. . . . . . . . . . . . . . . . . . .
Sequence of Operation
23
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Check for Refrigerant Leaks
28
. . . . . . . . . . . . . . . . . . . . . . . . .
Start--Up Adjustments
28
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
A09032
Fig. 1 -- Unit 577D-- --A
Checking Cooling and Heating Control Operation
28
. . . . . .
Checking and Adjusting Refrigerant Charge
28
. . . . . . . . . . .
Refrigerant Charge
29
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
No Charge
29
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Low Charge Cooling
29
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
To Use Cooling Charging Charts
29
. . . . . . . . . . . . . . . . . . . .
Non--Communicating Emergency Cooling/Heating Mode
29
. .
MAINTENANCE
31--34
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Air Filter
31
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Indoor Fan and Motor
31
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Inducer Blower
31
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Limit Switch
31
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Burner Ignition
31
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Main Burners
31
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Inducer Pressure Switch
32
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Outdoor Coil, Indoor Coil, and Condensate Drain Pan
32
. . . . .
Outdoor Fan
32
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrical Controls and Wiring
32
. . . . . . . . . . . . . . . . . . . . . . .
Refrigerant Circuit
33
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Indoor Airflow
33
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pressure Switches
33
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Loss--of--Charge Switch
33
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
High--Pressure Switches
33
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Copeland Scroll Compressor (Puron
®
Refrigerant)
33
. . . . . . . .
Refrigerant System
33
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Refrigerant
33
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Compressor Oil
33
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Servicing Systems on Roofs with Synthetic Materials
33
. . . .
Liquid--Line Filter Drier
34
. . . . . . . . . . . . . . . . . . . . . . . . . .
Puron (R--410A) Refrigerant Charging
34
. . . . . . . . . . . . . . .
TROUBLESHOOTING
34
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FINAL CHECKS
35
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CARE AND MAINTENANCE
35
. . . . . . . . . . . . . . . . . . . . . . . .
START--UP CHECKLIST
39
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service maintenance,or use can cause explosion, fire, electrical shock, or other conditions which may cause death, personal injury, or propertydamage. Consult a qualified installer, service agency, or your distributor or branch f...
3 A B C MAXIMUM ALLOWABLE DIFFERENCE in. (mm) A-C 1/4 1/4 1/4 (6.35) (6.35) (6.35) A-B B-C A07925 Fig. 2 -- Unit Leveling Tolerances Installation on older “G” series roof curbs. Two accessory kits are available to aid in installing a new “G” series unit on an old “G” roof curb. 1. Accessory kit numb...
9 ACCESS PANELS MUST BE IN PLACE WHEN RIGGING. PANNEAUX D'ACCES DOIT ÊTRE EN PLACE POUR MANIPULATION. 50CY502286 2.0 CAUTION - NOTICE TO RIGGERSPRUDENCE - AVIS AUX MANIPULATEUR Use top skid as spreader bar. / Utiliser la palette du haut comme barre de répartition SEAL STRIP MUST BE INPLACE BEFORE PL...