Bryant 558F - Manual

Bryant 558F

Bryant 558F – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
61 Page 61
62 Page 62
63 Page 63
64 Page 64
65 Page 65
66 Page 66
67 Page 67
68 Page 68
Page: / 68

Table of Contents:

  • Page 3 – Time Guard
  • Page 4 – MODEL DESCRIPTION; LEGEND
  • Page 5 – ARI* CAPACITY RATINGS
  • Page 8 – KO — Knockout
  • Page 11 – SERVICE PLATE SIZES
  • Page 12 – DIMENSIONAL DRAWING — HORIZONTAL AND VERTICAL ROOF CURBS
  • Page 17 – SELECTION PROCEDURE (With 559F180 Example)
  • Page 18 – GROSS COOLING CAPACITIES
  • Page 48 – FAN RPM AT MOTOR PULLEY SETTINGS*; ELECTRIC HEAT MULTIPLICATION FACTORS
  • Page 55 – OPERATING SEQUENCE
  • Page 58 – Vertical Discharge Ducting; NEC — National Electrical Code; Horizontal Discharge Ducting
  • Page 59 – LEGEND FOR TYPICAL WIRING SCHEMATICS
  • Page 60 – APPLICATION DATA; will not
  • Page 61 – OPTION AND ACCESSORY LIST; Concentric Duct Air Distribution
  • Page 62 – EVAPORATOR-FAN MOTOR PERFORMANCE
  • Page 63 – UNIT; Fan Performance Using Accessory
  • Page 64 – ELECTRIC HEATER CAPACITIES —
  • Page 68 – Bryant; Air Conditioning
Loading the manual

DESCRIPTION

The 558D/559F electric cooling rooftop units are designed to
deliver optimum performance and reliability in a commercial
rooftop unit. The 3 to 25 ton units are one-piece electric cooling
units that are prewired and precharged with R-22 at the factory,
making jobsite installation easy. Every unit is factory run-tested
prior to shipment to ensure reliable installation.

The 558D/559F units are designed to be field-convertible from
vertical supply/return to horizontal supply/return (180-300 units
require an accessory horizontal supply curb or adapter), making
them easily adaptable to a wide variety of new construction and
replacement applications. For vertical supply/return jobs, duct-
work can be connected directly to the roof curb, allowing duct-
work to be completed before unit is available for installation. All
units include easily replaceable internal filters.

The 558D/559F units are available with a range of accessory,
field-installed electric heating sizes and voltage options to meet
most job requirements. Low-voltage terminal blocks make wir-
ing connections quick and simple.

All units are listed with either UL (Underwriters’ Laboratories)
or ETL (ETL Testing Laboratory) and with CSA (Canadian Stand-
ards Association), UL Canada, or ETL Canada. All units are ARI
(Air-Conditioning & Refrigeration Institute) approved (except the
size 300, which is beyond the scope of the ARI Certification pro-
gram) and comply with ASHRAE Standard 62 (American Soci-
ety of Heating, Refrigeration, and Air Conditioning Engineers).

STANDARD FEATURES

EFFICIENT DESIGN means cooling energy savings. Standard
units have EERs (energy efficiency ratios) of up to 9.2, and
SEERs (Seasonal Energy Efficiency Ratios) of up to 10.0 (036-
060 units only).

THE FACTORY-ASSEMBLED PACKAGE (036-150 Units) is a
compact, fully self-contained electric cooling unit that is pre-
wired, prepiped, and precharged for minimum installation
expense.

UNITS MAY BE CONVERTED TO HORIZONTAL DIS-
CHARGE
in the field. The units can be modified at the jobsite to
fit a variety of applications (180-300 units require an accessory
horizontal supply/return roof curb or a horizontal supply/return
adapter).

NEW TOOL-LESS FILTER ACCESS PANEL (036-150 Units)
provides easy access to filters. The new panel provides addi-
tional access space, permitting easy filter replacement in the
unit, even with an outdoor-air device mounted in a horizontal
position.

INTERNAL RETURN-AIR FILTERS are provided. Two-in.
throwaway filters are provided standard on all units, and can be
easily accessed through the tool-less access filter door. There is
no need to field-fabricate filter racks or install external filter
accessories.

COMPRESSOR PROTECTION is assured. The 036-150 units
have an internal pressure relief valve and line break (current
overload) protections, and the 180-300 units have high- and
low-pressure and freeze protection external to the compressor.
These protections prohibit operation under abnormal unit
conditions.

Model 558D036-072

Model 558D090-150

Model 559F180,216

Model 559F240,300

Bryant

Air Conditioning

COMMERCIAL
SINGLE-PACKAGE ROOFTOP
ELECTRIC COOLING UNITS

Model 558D/559F

Sizes 036-300

3 to 25 Tons

Form No. PDS 558D.36.5B

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - Time Guard

Controls Upgrade Kit (036-150 Units) — The controls kit in-cludes high-pressure, loss-of-charge/low-pressure, and freezeprotection cutout switches. The high-pressure and loss-of-charge/low-pressure switches can be easily added by screwingthe switches onto Schrader-type fittings provided on the refri...

Page 4 - MODEL DESCRIPTION; LEGEND

Head Pressure Control — Kit consists of an outdoor-air ther-mostat that permits adequate head pressure control duringcooling operation at low outdoor-ambient temperatures. Refer to Trade Prices for more details or contact your localrepresentative. SUGGESTED USE: • When cooling at low-ambient outdoor...

Page 5 - ARI* CAPACITY RATINGS

ARI* CAPACITY RATINGS UNIT 558D NOMINAL TONS STANDARD CFM NET COOLING CAPACITY (Btuh) TOTAL kW SEER† EER SOUND RATING (Bels) Belt Drive Direct Drive 036 3 1200 35,000 4.0 10.0 9.7 8.7 8.2 048 4 1600 47,000 5.5 10.0 9.7 8.6 8.2 060 5 2000 57,500 6.7 10.0 9.7 8.5 8.2 UNIT NOMINAL TONS STANDARD CFM NET...

Other Bryant Models