Bryant 548J*14D - Manual

Bryant 548J*14D

Bryant 548J*14D – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
Page: / 36

Table of Contents:

  • Page 2 – SAFETY CONSIDERATIONS; WARNING
  • Page 4 – INSTALLATION; Jobsite Survey; Step 1 — Plan for Unit Location; NOTE
  • Page 5 – Ductwork must be attached to curb and
  • Page 7 – Step 5 — Field Fabricate Ductwork; Do not connect ductwork to unit.; For Units with Accessory Electric Heaters —; Step 6 — Rig and Place Unit; UNIT DAMAGE HAZARD; CAUTION; DETAIL “A”
  • Page 8 – Positioning on Curb —; Step 7 — Convert to Horizontal and Connect; without; Step 8 — Install Outside Air Hood; Factory Option —; Economizer Hood and Two–Position Hood
  • Page 9 – Two Position Damper Hood Removal and Setup --; Economizer Hood and Two–Position
  • Page 10 – Be careful not; Step 9 — Install External Condensate Trap and
  • Page 11 – All units must have an external trap for condensate; Step 10 — Make Electrical Connections; ELECTRICAL SHOCK HAZARD; Do not use gas piping as an electrical ground.
  • Page 12 – FIRE HAZARD
  • Page 13 – Units Without Disconnect Option; Convenience Outlets —
  • Page 14 – ELECTRICAL OPERATION HAZARD; Installing Weatherproof Cover:
  • Page 16 – Electric Heaters
  • Page 17 – Single Point Boxes; Heater and Supplementary Fuses —
  • Page 18 – Outdoor Air Enthalpy Control; Differential Enthalpy Control —
  • Page 21 – Table 2 – RTU--MP Controller Inputs and Outputs; Temperature (SAT) Sensor on Small Rooftop Units
  • Page 22 – Field Connections
  • Page 23 – SET; Economizer Controls —; Wiring the Indoor Air Quality Sensor:
  • Page 24 – COVER REMOVED
  • Page 25 – BACview; Communication LEDs; SW3 Protocol Selection; Baud Rate Selections
  • Page 26 – The LEDs on the RTU--MP show the status of certain functions; Tx
  • Page 27 – Smoke D
  • Page 28 – Smoke Detector Locations
  • Page 29 – Completing Installation of Return Air Smoke Sensor:; Sampling Tube; Additional Application Data —
  • Page 30 – : See page 32 for table legend and notes.
  • Page 32 – Legend and Notes for Table 4; IV Wiring; Step 11 — Adjust Factory--Installed Options; Smoke Detectors —
  • Page 33 – Step 12 — Install Accessories; Available accessories include:
Loading the manual

548J*14D

SINGLE PACKAGE ROOFTOP

HEAT PUMP

WITH WITH PURON

R

(R--410A) REFRIGERANT

SIZE 14

Installation Instructions

NOTE

: Read the entire instruction manual before starting

the installation.

TABLE OF CONTENTS

SAFETY CONSIDERATIONS

1

. . . . . . . . . . . . . . . . . . . .

INSTALLATION

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Jobsite Survey

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Step 1 -- Plan for Unit Location

4

. . . . . . . . . . . . . . . . . .

Roof Mount

5

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Step 2 -- Plan for Sequence of Unit Installation

5

. . . . . .

Curb--Mount Installation

5

. . . . . . . . . . . . . . . . . . . . .

Pad--Mount Installation

5

. . . . . . . . . . . . . . . . . . . . . .

Frame--Mount Installation

5

. . . . . . . . . . . . . . . . . . . .

Step 3 -- Inspect Unit

5

. . . . . . . . . . . . . . . . . . . . . . . . . . .

Step 4 -- Provide Unit Support

5

. . . . . . . . . . . . . . . . . . .

Roof Curb Mount

5

. . . . . . . . . . . . . . . . . . . . . . . . . .

Slab Mount (Horizontal Units Only)

5

. . . . . . . . . . .

Alternate Unit Support

5

. . . . . . . . . . . . . . . . . . . . . .

Step 5 -- Field Fabricate Ductwork

7

. . . . . . . . . . . . . . . .

For Units with Accessory Electric Heaters

7

. . . . . .

Step 6 -- Rig and Place Unit

7

. . . . . . . . . . . . . . . . . . . . .

Step 7 -- Convert to Horizontal & Connect Ductwork

8

.

Step 8 -- Install Outside Air Hood

8

. . . . . . . . . . . . . . . .

Economizer Hood Removal and Setup

8

. . . . . . . . .

Two Position Damper Hood Removal and Setup

9

. .

Economizer Hood and Two--Position Hood

10

. . . . .

Step 9 -- Install External Condensate Trap and Line

10

.

Step 10 -- Make Electrical Connections

11

. . . . . . . . . . .

Field Power Supply

11

. . . . . . . . . . . . . . . . . . . . . . . .

Units without Factory--Installed Disconnect

13

. . . .

Units with Factory--Installed Disconnect

13

. . . . . . .

Convenience Outlets

13

. . . . . . . . . . . . . . . . . . . . . . .

Factory--Option Thru--Base Connections

15

. . . . . . .

Units without Thru--Base Connections

15

. . . . . . . . .

Field Control Wiring

15

. . . . . . . . . . . . . . . . . . . . . . .

Thermostat

15

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Unit without Thru--Base Conversion Kit

16

. . . . . . .

Heat Anticipator Settings

16

. . . . . . . . . . . . . . . . . . .

Electric Heaters

16

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Single Point Boxes

17

. . . . . . . . . . . . . . . . . . . . . . . . . .

Heater Low--Voltage Control Connections

17

. . . . . .

Outdoor Air Enthalpy Control

18

. . . . . . . . . . . . . . . . .

Differential Enthalpy Control

18

. . . . . . . . . . . . . . . .

Return Air Enthalpy Sensor

18

. . . . . . . . . . . . . . . . .

RTU--MP Control System

19

. . . . . . . . . . . . . . . . . . . . . .

Supply Air Temperature (SAT) Sensor

21

. . . . . . . . .

Outdoor Air Temperature (OAT) Sensor

22

. . . . . . .

EconoMi$er2

22

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Field Connections

22

. . . . . . . . . . . . . . . . . . . . . . . . . .

Space Temperature (SPT) Sensors

22

. . . . . . . . . . . .

Economizer Controls

23

. . . . . . . . . . . . . . . . . . . . . .

Indoor Air Quality (CO

2

) Sensor

23

. . . . . . . . . . . . .

Outdoor Air Quality Sensor

24

. . . . . . . . . . . . . . . . .

Connecting Discrete Inputs

24

. . . . . . . . . . . . . . . . . .

Communication Wiring -- Protocols

25

. . . . . . . . . . . .

General

25

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Local Access

25

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

RTU--MP Troubleshooting

25

. . . . . . . . . . . . . . . . . .

Smoke Detectors

27

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

System

27

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Controller

27

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Sensor

27

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Smoke Detector Locations

28

. . . . . . . . . . . . . . . . . . . .

Supply Air

28

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Return Air without Economizer

28

. . . . . . . . . . . . . .

Return Air with Economizer

28

. . . . . . . . . . . . . . . . .

Step 11 -- Adjust Factory--Installed Options

32

. . . . . . . .

Step 12 -- Install Accessories

33

. . . . . . . . . . . . . . . . . . .

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - SAFETY CONSIDERATIONS; WARNING

2 SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock or other conditions which may cause personal injury or property damage. Consult a qualified installer, service agency, or your distributor or branch for inf...

Page 4 - INSTALLATION; Jobsite Survey; Step 1 — Plan for Unit Location; NOTE

4 C10364 Fig. 1 -- Unit Dimensional Drawing – Size 14 Unit (cont.) INSTALLATION Jobsite Survey Complete the following checks before installation. 1. Consult local building codes and the NEC (National Electrical Code) ANSI/NFPA 70 for special installa- tion requirements. 2. Determine unit location (f...

Page 5 - Ductwork must be attached to curb and

5 Roof Mount — Check building codes for weight distribution requirements. Unit operating weight is shown in Table 1. Table 1 – Operating Weights 548J*14D UNITS LB (KG) Component 14D Base Unit 1370 (620) Economizer Vertical 100 (45) Horizontal 115 (52) Powered Outlet 32 (15) Curb 14 --- in/356 mm 180...

Other Bryant Models