Bryant 5200 - Manual

Bryant 5200

Bryant 5200 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
Page: / 11

Table of Contents:

  • Page 2 – Replacing Existing Thermostat; I N S TA L L AT I O N; Replacing Existing Thermostat cont.; single stage heating or cooling systems.; Installing Your New Thermostat; thermostat performance.; OFF
  • Page 3 – RESET; Read BEFORE Testing; Default Thermostat Settings
  • Page 4 – Setting Current Time of Day and Day of Week cont.; Setting First Stage Differential; RESUME; Setting Second Stage Differential; Setting Temperature Differential and Residual; Setting Second Stage Differential
  • Page 5 – Setting Your Energy Saving Programs; Tips Before Starting; Whole Week –; Using Quick Program Groups or Individual Day Programming; Entering Your Program; Setting Your Energy Saving Programs cont.yt; Using Quick Program Groups or Individual Day Programming cont.; MORN; Individual Days –
  • Page 6 – Setting Your Energy Saving Programs cont.; A D D I T I O N A L O P E R AT I O N F E AT U R E S; Entering Your Program cont.; settings, gently press; Review Set Temperature; REMEMBER; this thermostat includes an automatic compressor protection; Compressor Protection; A D D I T I O N A L; Temporary Program Override
  • Page 7 – HEAT; Read BEFORE proceeding; Replacing the Back-up Batteries
  • Page 8 – SYMPTOM; SYMPTOM; is shown in
  • Page 9 – Installation; LO; is shown in the; Comfortmaker and Heil-Quaker; THERMOSTAT TERMINAL BLOCK; Coleman, Rheem and Ruud; THERMOSTAT TERMINAL BLOCK
  • Page 10 – Lennox; W I R I N G D I A G R A M S
  • Page 11 – Typical; York E1 Series; Heat Pumps; WARRANTY; YEAR; LIMITED; Braeburn Systems LLC
Loading the manual

MODEL

5200

OWNERS MANUAL

Premier Series

7-Day Programmable

2-Heat / 2-Cool & Heat Pump

Digital Thermostat

Compatible with low voltage multi-stage heat

pump systems with up to two stages of heating

and two stages of cooling. Not for use on

single-stage heating or cooling systems.

READ ALL INSTRUCTIONS BEFORE PROCEEDING

© 2004 Braeburn Systems LLC All Rights Reserved.

Pub. No. 5200-100-002

Store this

booklet for

future reference

Braeburn Systems LLC, as an Energy Star partner

has determined that this product meets the Energy

Star Guidelines developed by the U.S. Environmental

Protection Agency & the U.S. Department of Energy

for maximum energy efficiency.

WARRANTY

YEAR

LIMITED

C O N T E N T S

WA R N I N G !

Quick Reference/Installation Guide

Important Safety Information

• Always turn off power to the air conditioning or heating system prior to installing,

removing, cleaning or servicing thermostat.

• Read this manual thoroughly prior to installing, programming or operating this

thermostat.

• This thermostat is designed for use with a 24 Volt AC low voltage multi-stage heat

pump system.

• Do not use this thermostat on single stage systems or other systems with

voltages higher than 30 Volt AC.

• This thermostat requires 24 Volt AC power for normal operation and control of the

heating or cooling system.

• This thermostat also requires two (2) properly installed "AA" alkaline batteries to

retain user settings and programs in the event of loss of AC Power due to power

outage or rolling blackouts.

• Wiring must conform to all building codes and ordinances as required by local

and national code authorities having jurisdiction.

• Do not short (or jumper) across terminals on the gas valve or at the heating or

cooling system control board to test the thermostat installation. This could

damage the thermostat and void the warranty.

• Do not select

COOL

mode of operation if the outside temperature is below 50˚ F

(10˚ C). This could possibly damage the controlled cooling system and may cause

personal injury.

• This thermostat should only be used as described in this manual. Any other use

is not recommended and will void the warranty.

1

FEATURES
SPECIFICATIONS
INSTALLATION

Replacing Existing Thermosta t

Installing Your New Thermosta t

TESTING YOUR NEW THERMOSTAT
PROGRAMMING

Default Thermosta t Settings

Setting Current Time of Day and Day of Week

Setting Tempera ture Differential and Residual

Cooling Fan Fea ture

Setting First Stage Differential
Setting Second Stage Differential
Setting Residual Cooling Fan Feature

Setting Your Energ y Sa ving Programs

Tips Before Starting
Using Quick Program Groups
or Individual Day Programming
Entering Your Program

ADDITIONAL OPERATION FEATURES

Review Set Tempera ture

Temporar y Program Override

Permanent Hold (Vaca tion) Mode

Efficient Recover y Mode (ERM™)
Compressor Protection

High Tempera ture Safety Switch

Changing Fahrenheit (˚F) to Celsius (˚C)

Lo w Ba tter y Detection and Replacement

Replacing the Back-up Ba tteries

Resetting Thermosta t
Multi-Colored LED Indica tors

TROUBLESHOOTING
WIRING DIAGRAMS

1

2

3

4
5

6

7
8

5.1

3.1
3.2

5.2
5.3

5.4

6.1
6.2
6.3
6.4
6.5
6.6
6.7
6.8

6.9

6.10

5.3

.1

5.3

.2

5.3

.3

5.4

.1

5.4

.2

5.4

.3

6.8

.1

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Replacing Existing Thermostat; I N S TA L L AT I O N; Replacing Existing Thermostat cont.; single stage heating or cooling systems.; Installing Your New Thermostat; thermostat performance.; OFF

F E AT U R E S S P E C I F I C AT I O N S 1 2 2 • Contemporary styling with large display • 7 Day Programming Flexibility • AC Powered with Battery Back-up (2 AA Alkaline batteries included) • Relay Outputs for Maximum Compatibility • Easy Access Front Battery Door • Pre-programmed for quick install...

Page 3 - RESET; Read BEFORE Testing; Default Thermostat Settings

4 7. Mark placement of mounting holes as appropriate and drill using a 3/16" drill bit. 8. Gently tap supplied plastic anchors into the holes in the wall. 9. Place the thermostat rear body (mounting plate) against the wall in the desired location making sure the mounting holes are aligned as app...

Page 4 - Setting Current Time of Day and Day of Week cont.; Setting First Stage Differential; RESUME; Setting Second Stage Differential; Setting Temperature Differential and Residual; Setting Second Stage Differential

c o n t . 6 P R O G R A M M I N G 5 5.2 Setting Current Time of Day and Day of Week cont. 5.3 Setting Temperature Differential and Residual Cooling Fan Feature Setting First Stage Differential NOTE: The thermostat will return to normal operating mode automatically after 15 seconds if no key is press...

Other Bryant Models

All Bryant Other