Bryant 395CAV - Manual
Bryant 395CAV – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – in. dia holes are located in the top plate.; MEDIA FILTER CABINET; UNIT; ama
- Page 3 – CONTROLS—THERMOSTATS AND ZONING; MINIMUM INCHES CLEARANCE TO COMBUSTIBLE CONSTRUCTION; Vent Clearance to combustibles:
- Page 4 – SPECIFICATIONS; UNIT SIZE
Form No. PDS 395CAV.40.8
ENERGY-EFFICIENT
INDUCED-COMBUSTION
DELUXE UPFLOW FURNACE
395CAV
Sizes 045 thru 155
Series H and J
With a unique approach to induced-combustion design, a 40-in.
tall cabinet, 4-pass heat exchanger, an inshot burner system,
and its safety features, this furnace is without peer. The model
395CAV Deluxe Induced-Combustion Upflow Furnace achieves
one of the highest Annual Fuel Utilization Efficiency (AFUE) rat-
ings available in a noncondensing, induced-combustion furnace.
Its ease and economy of installation, ease of serviceability, eco-
nomical initial cost, and short payback time put it in a class well
ahead of the competition. The model 395CAV Gas Furnace has
the kind of overall performance needed in today’s homes. All
models are GAMA efficiency rating certified and certified for use
in California Air Quality Management Districts.
FEATURES
EFFICIENCY
—The 395CAV Deluxe Induced-Combustion Gas
Furnace provides the efficiency customers want with 80.0 per-
cent AFUE.
MEDIA FILTER CABINET
—Enhanced indoor air quality in your
home is made easier with our media filter cabinet—a standard
accessory on all deluxe upflow furnaces. When installed as a
part of your system, this cabinet allows for easy and convenient
addition of a Bryant high-efficiency air filter.
HOT SURFACE IGNITION
—This field proven ignition system
will save energy and improve reliability.
ALUMINIZED HEAT EXCHANGER
—The patented 4-pass heat
exchanger is made of aluminized steel and backed by a 20-year
Limited Warranty.
INTELLIGENT CONTROL BOARD
—The 395CAV Furnace has
an intelligent control board with an LED status indicator light to
ensure top furnace performance. This control board also has a
self-test feature that enables the servicing technician to verify
operation of the board itself, the inducer, the hot surface ignitor,
both high- and low-speed blower operation, and the humidifier.
The board also features a 3-amp fuse that protects the trans-
former and board. We guarantee the reliability of the control
board with a 3-year Limited Warranty.
40-IN. HEIGHT
—The 395CAV Deluxe Induced-Combustion
Furnace with a 40-in. cabinet height simplifies installation in al-
coves, attics, basements (ideal for short basement), closets, and
utility rooms, especially with a high-efficiency cooling coil.
PREPAINTED CABINET
—The 395CAV uses prepainted sheet
metal for the cabinet. This is the same high-quality finish found
on refrigerators and other appliances today. We ensure its dura-
bility by using a galvanized steel substrate to provide superior
rust protection.
PATENTED BLOCKED VENT SAFEGUARD
—Our induced-
combustion furnace has a patented blocked vent safeguard. The
safeguard will stop furnace operation if the vent system be-
comes blocked or is not operating properly. An exclusive with the
395CAV Furnace.
EASY INSTALLATION
—The model 395CAV has many fea-
tures that make installation easier: left or right gas and electrical
connections, Molex blower speed selector, matching coil sizes,
accessory low-voltage connections, and many more.
QUIET OPERATION
—A soft mount inducer assembly and slow
opening gas valve improves sound level.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
— 2 — A98520 A D 13 ⁄ 16 ″ E 11 ⁄ 16 ″ 11 ⁄ 16 ″ 28 1 ⁄ 2 ″ 39 7 ⁄ 8 ″ 24 5 ⁄ 16 ″ 11 ⁄ 16 ″ 3 ″ 2 1 ⁄ 16 ″ 1 ″ 12 5 ⁄ 16 ″ 5 3 ⁄ 8 ″ 5 13 ⁄ 16 ″ 2 3 ⁄ 8 ″ AIR INLET 7 ⁄ 8 -IN. DIA HOLE POWER ENTRY 7 ⁄ 8 -IN. DIA ACCESSORY 1 3 ⁄ 4 -IN. DIA HOLE GAS ENTRY 1 ⁄ 2 -IN. DIA HOLE THERMOSTAT WIRE ENTRY SID...
— 3 — A98122E CONTROLS—THERMOSTATS AND ZONING THERMOSTAT—NON-PROGRAMMABLE Auto Changeover, °F/°C, 1-Stage Heat/1-Stage Cool — TSTATBBNAC01-BAuto Changeover, °F/°C, 2-Stage Heat/1-Stage Cool — TSTATBBNHP01-B Auto Changeover, °F/°C, 2-Stage Heat/2-Stage Cool — TSTATBBN2S01-B in AC Mode, 3-Stage Heat i...
— 4 — SPECIFICATIONS * Gas input ratings are certified for elevations to 2000 ft. For elevations above 2000 ft, reduce ratings 4 percent for each 1000 ft above sea level. Refer to National Fuel Gas Code Table F4 or furnace Installation Instructions. In Canada, derate the unit 10 percent for elevatio...