Table of Contents:

  • Page 2 – WARNING; WARNING; Combustion Air Checks; Make the inspection as follows:; WARNING; If draft hood spillage is indicated:
  • Page 5 – Single Stage; Furnace Maintenance; Pressure Switches; Replacement Filters
  • Page 6 – CAUTION
Loading the manual

1

359AAV

UPFLOW / HORIZONTAL / DOWNFLOW

HIGH EFFICIENCY GAS FURNACE

Owner’s Manual

NOTE TO INSTALLER:

THIS MANUAL MUST BE LEFT

WITH THE EQUIPMENT USER.

USER:

Please read all instructions in the manual and retain all

manuals for future reference.

FIRE OR EXPLOSION HAZARD

Failure to follow safety warnings could result in injury, death,

or property damage.
Do not store or use gasoline or other flammable vapors and

liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS

--Do not try to light any appliance.

--Do not touch any electrical switch; do not use any

phone in your building.

--Leave the building immediately.

--Immediately call your gas supplier from a neighbor’s

phone. Follow the gas supplier’s instructions.

--If you cannot reach your gas supplier, call the fire

department.

Installation and service must be performed by a qualified

installer, service agency or the gas supplier.

!

WARNING

CARBON MONOXIDE POISONING HAZARD

Failure to follow this warning could result in personal

injury and/or death.
Carbon Monoxide is invisible, odorless, and toxic! A

carbon monoxide alarm is recommended in your home,

even if you do not own a gas appliance. Locate the carbon

monoxide alarm in the living area of your home and away

from gas appliances and doorways to attached garages.

Follow the alarm manufacturer’s instruction included with

the alarm.

!

WARNING

Do not use this furnace if any part has been under water. A

flood--damaged furnace is extremely dangerous. Attempts to

use the furnace can result in fire or explosion. A qualified

service agency should be contacted to inspect the furnace

and to replace all gas controls, control system parts,

electrical parts that have been wet or the furnace if deemed

necessary.

C E R T I F I E D

D E

S I G N

C

E R

T I F I E

D

ama

As an ENERGY STAR
Partner, we have
determined that this
product meets the
ENERGY STAR guidelines
for energy efficiency.

SAFETY CONSIDERATIONS

Recognize safety information. This is the safety--alert symbol

.

When you see this symbol on the furnace and in instructions or
manuals, be alert to the potential for personal injury.
Understand the signal words:

DANGER, WARNING, and

CAUTION. DANGER identifies the most serious hazards which

will

result in severe personal injury or death. WARNING signifies

hazards which

could

result in personal injury or death. CAUTION

is used to identify unsafe practices which

may

result in minor

personal injury or product and property damage. NOTE is used to

highlight suggestions which

will

result in enhanced installation,

reliability or operation.
To minimize the possibility of serious personal injury, fire, furnace
damage, or improper operation;

carefully follow these safety

rules

:

S

Your gas furnace uses air from outside the home for combustion
and vents flue gas to the outdoors. It is not to be installed using
indoor air for combustion. The vent pipe must terminate outside
the structure and must not be obstructed in any way. The
air--intake pipe must terminate outside the structure or in a well
ventilated area that is isolated from the living space and the
garage (e.g. well ventilated attic or crawlspace). Do not block or
obstruct air openings on furnace or spaces around furnace.

S

Keep the area around your furnace clear and free of combustible
materials, gasoline, and other flammable liquids and vapors.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - WARNING; WARNING; Combustion Air Checks; Make the inspection as follows:; WARNING; If draft hood spillage is indicated:

2 Combustion Air (Your Safety) CARBON MONOXIDE POISONING HAZARD Failure to follow this warning could result in personal injury or death.All fuel--burning appliances must be provided with enough fresh air for proper combustion and ventilation of flue gases.Some models use air from the space in which ...

Page 5 - Single Stage; Furnace Maintenance; Pressure Switches; Replacement Filters

5 1/4” SpadeConnection Single Stage On\Offtoggleswitch INLET OUTLET A07694 Fig. 3 -- Gas Control Valve 2. Have someone check the structure frequently during cold weather to make sure it is warm enough to prevent pipesfrom freezing. Instruct them to call a qualified service agency to call to provide ...

Page 6 - CAUTION

6 Filter rack(s) attached to the outside of the furnace is made so thefilter simply slides out one end for removal. PROPERTY DAMAGE HAZARD Failure to follow this warning could result in increase furnace operating temperatures and shorten the life of the furnace.Filters specified for the furnace are ...