Table of Contents:

  • Page 4 – PHYSICAL DATA; SPST; Always Ask For
  • Page 6 – MECHANICAL; THERMOSTATS; HUMIDIFIER
  • Page 8 – LENGTH OF STRAIGHT; CASING WIDTH; INTAKE/COMBUSTION AIR
  • Page 9 – Shipped with sizes
  • Page 10 – CLEARANCE TO COMBUSTIBLES
  • Page 11 – PERFORMANCE DATA
  • Page 18 – WITHOUT INSULATION IN WINTER DESIGN TEMPERATURE AMBIENT*
  • Page 20 – TYPICAL INSTALLATIONS; OUTDOOR UNIT; Upflow Application; ELECTRONIC; Downflow Application
  • Page 22 – GUIDE SPECIFICATIONS; Plus; PRODUCTS
Loading the manual

1

353AAV

Plus

90x

4--Way Multipoise Condensing Gas Furnace

Input Rates: 40,000 Only

Product Data

4--WAY MULTIPOISE DESIGN ALLOWS

MORE APPLICATIONS

A05085

A UNIQUE SEER SOLUTION

The

Plus

90x is an exciting addition to your product line. This

high--efficiency 4--way multipoise design furnace allows more

applications while the ECM motor and Bryant’s control logic

combine to provide a SEER increase of up to 1.5 points.*
Some of Bryant’s best--engineered components contribute to the

efficient performance of this condensing furnace. The

Plus

90x

utilizes Power Light

t

hot surface ignition (HSI), which ignites

the burners directly. HSI eliminates gas waste that typical

continuous--pilot designs can bring. Hot surface ignition has

proven to contribute to reliable start--up and operation of Bryant

furnaces.
Another deluxe feature included with this furnace is Bryant’s

trusted Everlastic

t

secondary heat exchanger; a patented

polypropylene laminate that provides exceptional heat transfer

and corrosion resistance. Using the exclusive flow--through

design, the secondary heat exchanger reduces the pressure drop in

the furnace resulting in lower electrical usage. The high

efficiency achieved by superior heat transfer is made only

better—by optimizing the efficient ECM motor speed tap

locations.
A standard media filter cabinet accessory is provided with the

Plus

90x in order to provide an opportunity to enhance indoor air

quality. As with all other Bryant furnaces, this model is designed

to work as a part of the total home comfort system which includes

elements for cooling, air cleaning, humidification, ventilation and

zoning. Boosting the unit’s efficiency with the ECM motor and

Bryant’s deluxe features show the

Plus

90x has been designed

with the homeowner in mind.

PLUS

90X FEATURES & BENEFITS

Everlastic

TM

— Exclusive Everlastic coating, a patented

polypropylene laminate is used on the secondary heat exchanger

and greatly reduces maintenance.

Perfect Light

Igniter

— Bryant’s unique Perfect Light

igniter is not only physically robust but it is also electrically

robust. It is capable of running at line voltage and does not

require complex voltage regulators as do other brands. This

unique feature further enhances the reliability of the

Plus

90x gas

furnace and continues Bryant’s tradition of technology leadership

and innovation in providing a reliable and durable product.

FanOn

— Improves comfort all year long by allowing the

homeowner to select different fan speeds during continuous fan

operation to achieve more or less airflow. This is done right at the

thermostat.

SmartEvap

— This feature allows your system to reduce

summertime humidity levels by nearly 10% over standard

systems.

Media Filter Cabinet

— Enhanced indoor air quality in your

home is made easier with our media filter cabinet—a standard

accessory on all Deluxe furnaces. When installed as a part of your

system, this cabinet allows for easy and convenient addition of a

Bryant high--efficiency air filter.

Control Center

— Microprocessor controls sequencing and

furnace operation. Equipped with a component test feature and

status indicator light to assist in troubleshooting. Microprocessor

controls blower times to start blower after main burners ignite to

eliminate cold air blowing into rooms.

*as compared to the Air --- Conditioning, Heating and Refrigeration Institute’s standard coil --- only rating (A/Cs up to 3.5 tons) when paired with selected Bryant

evaporator coils.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 4 - PHYSICAL DATA; SPST; Always Ask For

4 PHYSICAL DATA **Note: 060--120 Sizes are phasing out.** UNIT SIZE 036040 036060 036080 048080 060100 060120 SHIPPING WEIGHT LB. (KG) 175 (47) 182 (57) 198 (64) 205 (69) 232 261 (74) LIMIT CONTROL SPST HEATING BLOWER CONTROL (Off Delay) Solid --- State Time Operation BURNERS (Monoport) 2 3 4 4 5 6 ...

Page 6 - MECHANICAL; THERMOSTATS; HUMIDIFIER

6 A93086 CONCENTRIC VENT (DIRECT VENT/ 2-PIPE ONLY) A concentric vent kit allows vent and combustion-air pipes toterminate through a single exitin a roof or side wall. One pipe runs inside the otherallowing venting through the inner pipe and combustion air to be drawn in through the outer pipe. A882...

Page 8 - LENGTH OF STRAIGHT; CASING WIDTH; INTAKE/COMBUSTION AIR

8 DOWNFLOW SUBBASE DIMENSIONS -- IN. (MM) FURNACE CASING WIDTH FURNACE IN DOWNFLOW APPLICATION PLENUM OPENING FLOOR OPENING HOLE NO. FOR WIDTH ADJUST --- MENT A B C D 17-1/2 (445) Furnace with or without Cased Coil Assembly or Coil Box 15 --- 1/8 (384) 19 (483) 16-3/4 (425) 20 --- 3/8 (518) 3 21 (53...