  • Page 2 – Important Safety Information; WARNING
  • Page 5 – Insulating the Flexible Exhaust Piping; Installing Refrigerator into the Enclosure; Propane System; Testing of the Vehicle’s Gas Supply Piping; Gas Burner Flame
  • Page 6 – Check Out of Flame Failure Safety Device; Description of Controls
  • Page 7 – Lighting and Start-Up Instructions; AC Operation
  • Page 8 – Norcold Limited Warranty Time Allowance Chart; Rialta
  • Page 9 – Wiring Pictorial & Diagram
  • Page 10 – Important Safety Information - AC Circuit
  • Page 11 – Specifications
  • Page 12 – Important Safety Information - DC Circuit
  • Page 14 – Important Safety Information - Gas Circuit
  • Page 15 – Note
  • Page 18 – Important Safety Information - DC Fan Circuit
  • Page 20 – Diagnosing Cooling Problems; Diagnostic Procedures
  • Page 21 – Refrigerator Removal Procedures; EuroVan Camper
  • Page 23 – Description
  • Page 26 – Control Cover Assembly - 3163
Loading the manual

Service Manual

Model 3163

Part No.: 617898A (94-11)

Contents

Important Safety Information . . . . . . . . . . 1
Specifications . . . . . . . . . . . . . . . . . . 2
General Information . . . . . . . . . . . . . . 2
Direct Vent Requirements . . . . . . . . . . . 2
Propane System . . . . . . . . . . . . . . . . 4
Description of Controls . . . . . . . . . . . . . 5
Lighting and Start-Up Instructions . . . . . . . 6
Limited Warranty Time Allowance Chart . . . . 7
Refrigerator Will Not Operate on AC . . . . . 8-9
Refrigerator Will Not Operate on DC . . . 10-11

No Spark at Burner . . . . . . . . . . . . 12-13
Burner Ignites But Flame Will Not Hold . . 14-15
Trouble Shooting - Ventilation Fan . . . . 16-17
Diagnosing Cooling Problems . . . . . . . . . 18
Refrigerator Removal & Re-Installation

Procedure (EuroVan Camper) . . . . . . . . 19
Refrigerator Removal & Re-Installation

Procedure (Rialta) . . . . . . . . . . . . . . . 20
Wiring Pictorial & Diagram . . . . . . . . . . 21
Parts List & Exploded Views . . . . . . . 22-27

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Important Safety Information; WARNING

Important Safety Information Read this information before attempting to perform service on this refrigerator. Page 8 shows a wiring pictorial and diagram. Review both the wiring pictorial and diagram to understand the electrical circuits and the relationship to the individual components. Understand ...

Page 5 - Insulating the Flexible Exhaust Piping; Installing Refrigerator into the Enclosure; Propane System; Testing of the Vehicle’s Gas Supply Piping; Gas Burner Flame

Insulating the Flexible Exhaust Piping The flexible exhaust pipe must be insulated prior to installation into the vent terminal housing. The flexible exhaust pipe connects to the flue tube of the refrigera- tor’s cooling unit and routes to the bottom opening of the vent terminal housing. Use the non...

Page 6 - Check Out of Flame Failure Safety Device; Description of Controls

Check Out of Flame Failure Safety Device 1. To verify operation of the flame failure safety device, start the refrigerator in the gas mode (refer to lighting instructions on page 6) and verify the presence of a flame. 2. Turn off the gas at the manual shut-off valve or at the main gas supply tank. 3...