Bryant 315AAV - Manual

Bryant 315AAV

Bryant 315AAV – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
Page: / 60

Table of Contents:

  • Page 2 – SAFETY CONSIDERATIONS; WARNING
  • Page 4 – CAUTION
  • Page 5 – If you touch ungrounded objects (and recharge your body; LOCATION; NOTE
  • Page 6 – FIRE, INJURY OR DEATH HAZARD
  • Page 7 – MINIMUM TO BURNERS; FIRE HAZARD; LOCATION RELATIVE TO COOLING EQUIPMENT
  • Page 8 – EXAMPLES: Determining Free Area; FURNACE; OTHER THAN FAN-ASSISTED TOTAL; AIR FOR COMBUSTION AND; FURNACE CORROSION HAZARD; CARBON MONOXIDE POISONING HAZARD
  • Page 10 – National Fuel Gas Code ANSI; Other; ACH; Volume; Fan; ACH; fan; INSTALLATION
  • Page 12 – mm) and larger may be used for flame roll--out protection when; Bottom Return Air Inlet; perform the following:; Side Return Air Inlet
  • Page 13 – The Air Systems
  • Page 14 – UPFLOW
  • Page 16 – M IN
  • Page 20 – UNION; ELECTRICAL CONNECTIONS; ELECTRICAL SHOCK AND FIRE HAZARD; FURNACE MAY NOT OPERATE HAZARD
  • Page 23 – Fig. 26 -- Variable Speed Furnace Control for ECM Blower Motor
  • Page 24 – General Venting Requirements
  • Page 25 – tioner
  • Page 26 – page following these figures; See notes 1 and 2 on the page
  • Page 32 – then Up; following these figures
  • Page 33 – connector is required, refer to Note 1 above.
  • Page 34 – Sidewall Venting; CHECK; General; CUT HAZARD
  • Page 35 – THERMOSTAT SUBBASE; CONTROL TERMINALS; FIRE AND EXPLOSION HAZARD; ELECTRICAL SHOCK HAZARD
  • Page 36 – Table 10 – Furnace Setup Switch Description; SETUP SWITCH; SERVICE; Adjustments; FURNACE DAMAGE HAZARD
  • Page 37 – ALTITUDE; Table 12 – Blower Off Delay Setup Switch; For 22,000 Btuh per burner application use Table
  • Page 39 – : 6 ton airflow will truncate at 2200 cfm on applicable
  • Page 51 – FIRE OR EXPLOSION HAZARD
  • Page 52 – Inducer Prepurge Period; ation the inducer motor IDM comes up to speed,
  • Page 53 – The thermostat “calls for cooling”.; : The air conditioning relay disable jumper ACRDJ must
  • Page 59 – Table 17 – Accessory List; DESCRIPTION
  • Page 60 – PARTS REPLACEMENT INFORMATION GUIDE; Consumer Relations Department
Loading the manual

1

Installation, Start--up, Operating and

Service and Maintenance Instructions

Series 150/F

315AAV/JAV

VARIABLE--SPEED, INDUCED--COMBUSTION DELUXE

4--WAY MULTIPOISE GAS FURNACE

SAFETY CONSIDERATIONS

2

. . . . . . . . . . . . . . . . . . . . . . . .

INTRODUCTION

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

CODES AND STANDARDS

4

. . . . . . . . . . . . . . . . . . . . . . . . . .

Safety

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

General Installation

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Combustion and Ventilation Air

4

. . . . . . . . . . . . . . . . . . . . . .

Duct Systems

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Acoustical Lining and Fibrous Glass Duct

4

. . . . . . . . . . . . . . .

Gas Piping and Gas Pipe Pressure Testing

4

. . . . . . . . . . . . . . .

Electrical Connections

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Venting

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS

PROCEDURE

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

LOCATION

5

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

AIR FOR COMBUSTION AND VENTILATION

8

. . . . . . . . .

Outdoor Combustion Air Method

9

. . . . . . . . . . . . . . . . . . . .

The Standard Method:

9

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

Combination of Indoor and Outdoor Air

10

. . . . . . . . . . . . .

INSTALLATION

10

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Bottom Return Air Inlet

10

. . . . . . . . . . . . . . . . . . . . . . . . . .

Side Return Air Inlet

10

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Leveling Legs (If Desired)

11

. . . . . . . . . . . . . . . . . . . . . . . .

Bottom Return Air Inlet

11

. . . . . . . . . . . . . . . . . . . . . . . . . .

Suspended Furnace Support

11

. . . . . . . . . . . . . . . . . . . . . . .

Platform Furnace Support

11

. . . . . . . . . . . . . . . . . . . . . . . . .

Roll--Out Protection

12

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Bottom Return Air Inlet

12

. . . . . . . . . . . . . . . . . . . . . . . . . .

Side Return Air Inlet

12

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Filter Arrangement

13

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

AIR DUCTS

13

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

General Requirements

13

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

Ductwork Acoustical Treatment

13

. . . . . . . . . . . . . . . . . . . .

Supply Air Connections

14

. . . . . . . . . . . . . . . . . . . . . . . . . .

Upflow and Horizontal Furnaces

14

. . . . . . . . . . . . . . . . . . .

Downflow Furnaces

15

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Return Air Connections

18

. . . . . . . . . . . . . . . . . . . . . . . . . .

Downflow Furnaces

18

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Upflow and Horizontal Furnaces

18

. . . . . . . . . . . . . . . . . . .

GAS PIPING

19

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

ELECTRICAL CONNECTION

20

. . . . . . . . . . . . . . . . . . . . . . .

ACCESSORIES

22

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

VENTING

22

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

START--UP, ADJUSTMENT, AND SAFETY CHECK

34

. . . . .

General

34

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Start--Up Procedures

37

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Adjustments

37

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Check Safety Controls

45

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Checklist

46

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SERVICE AND MAINTENANCE PROCEDURES

46

. . . . . . .

General

46

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Care and Maintenance

47

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Sequence of Operation

52

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Wiring Diagram

56

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Troubleshooting

56

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Accessory List

59

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

PARTS REPLACEMENT INFORMATION GUIDE

60

. . . . . . .

D E

S I G N

C

E R

T I F I E

D

REGISTERED

ISO 9001:2000

NOTE

: Read the entire instruction manual before starting the

installation.
Portions of the text and tables are reprinted from NFPA 54/ANSI
Z223.1--2009

E

, with permission of National Fire Protection

Association, Quincy, MA 02269 and American Gas Association,
Washington DC 20001. This reprinted material is not the

complete and official position of the NFPA or ANSI on the
referenced subject, which is represented only by the standard in

its entirety.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - SAFETY CONSIDERATIONS; WARNING

2 SAFETY CONSIDERATIONS FIRE, EXPLOSION, ELECTRICAL SHOCK, AND CARBON MONOXIDE POISONING HAZARD Failure to follow this warning could result in dangerous operation, personal injury, death, or property damage.Improper installation, adjustment, alteration, service, maintenance, or use can cause carbon ...

Page 4 - CAUTION

4 INTRODUCTION The Series 150/F 4--way multipoise Category I fan--assistedfurnace is CSA (formerly A.G.A. and C.G.A.) design--certified. A Category I fan--assisted furnace is an appliance equipped with anintegral mechanical means to either draw or force products of combustion through the combustion ...

Page 5 - If you touch ungrounded objects (and recharge your body; LOCATION; NOTE

5 A A B [736.9] [736.9] 29 29 Ø7/8 Ø7/8 [22.2] [22.2] ACCESSORY ACCESSORY 5 15/16 5 15/16 [150.7] [150.7] 28.39 28.39 [721.2] [721.2] Ø7/8 Ø7/8 [22.2] [22.2] ACCESSORY ACCESSORY 14 7/8 14 7/8 [337.3] [337.3] (BOTH SIDES) (BOTH SIDES) Ø7/8 Ø7/8 [22.2] [22.2] ACCESSORY ACCESSORY Ø7/8 Ø7/8 [22.2] [22.2...