1

Product Data

313AAV/JAV

Plus

80x

4--Way Multipoise

Induced Combustion Gas Furnace

Input Capacities: 45,000 thru 135,000 Btuh, Series B

A10256

THE BRYANT

Plus

80x GAS FURNACE

The

Plus

80x Deluxe 4--Way Multipoise Gas Furnace offers

outstanding features in an 80% AFUE furnace.
Deluxe features include: an ECM motor which enhances SEER

performance up to 1.5 points*, a third fan relay for discrete

continuous fan speed, the ability to change continuous fan speeds
from the thermostat (Fan on

Plus

t

), dehumidify mode, fault code

storage, and more. The

Plus

80x is very quiet thanks to a new

combustion design that eliminates noise, rather than just muffle or

box it in. Applications are easy with 4--way multipoise design,
through--the--furnace downflow venting, 13 different venting

options, and an overall design for easy service access. An inner

blower door is provided for tighter sealing in sensitive applications.
The 313JAV is approved for use in Low NOx Air Quality

Management Districts.

STANDARD FEATURES

S

ECM blower motor included

S

Noise elimination combustion system

S

SmartEvap

t

can lower the humidity level in the home by

nearly 10%

S

Certified to leak 2 percent or less of its nominal air
conditioning CFM delivered when pressurized to 1--In.
Water Gauge with all present air inlets, air outlets, and
condensate drain port(s) sealed.

S

Four--position furnace: Upflow, Horizontal Right,
Horizontal Left, Downflow

Thirteen different vent options

S

Compact design only 33--1/3 in. (847 mm) tall

S

Microprocessor based “smart” control center

Fan on

Plus

t

-- Continuous Fan speed adjustable from

thermostat
Adjustable heating air temperature rise
Dehumidify mode
Enhanced diagnostics with LED and reflective sight glass,
non--volatile fault code memory, and self--test feature
On--board fuse for transformer protection

S

Patented blocked vent safeguard to ensure proper furnace
venting

S

Insulated blower compartment

S

HYBRID HEAT

®

Dual Fuel System compatible

S

All models are chimney friendly when used with accessory
vent kit

S

Perfect Light

t

Igniter

S

Residential installations eligible for consumer financing
through the Comfort Credit Program

*as compared to the Air Conditioning Heating and Refrigeration Institute’s standard coil --- only ratings when paired with selected Bryant evaporator coils.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - BRYANT ACCESSORIES; MECHANICAL; THERMOSTATS; MODEL HUMCCLFP

2 BRYANT ACCESSORIES MECHANICAL OR ELECTRONIC AIR CLEANER Cleans the air of smoke, dirt, and many pollens commonly found. Saves decorating and cleaning expenses by keeping carpets, furniture, and drapes cleaner. Electronic air cleaner is shown. A97432 CONTROLS: THERMOSTATS AND ZONING Available in pr...

Page 4 - PHYSICAL DATA; BLOWER PERFORMANCE DATA

4 PHYSICAL DATA UNIT SIZE 024045 048070 048090 060110 060135 OUTPUT CAPACITY BTUH (Non --- weatherized ICS) 313JAV Upflow; all 313AAV 36,000 53,000 72,000 90,000 107,000 313JAV Downflow/Horizontal 34,000 51,000 69,000 86,000 102,000 INPUT BTUH 313JAV Upflow; all 313AAV 44,000 66,000 88,000 110,000 1...

Page 5 - Venting Notes; Downflow Vent Guard is used in downflow position.

5 SEE NOTES: 1,2,4,7,8,9 SEE NOTES: 1,2,3,4,7,8,9 SEE NOTES: 1,2,4,5,7,8,9 SEE NOTES:1,2,3,4,5,7,8,9 SEE NOTES: 1,2,3,4,7,8,9 SEE NOTES: 1,2,4,5,6,7,8,9 A02063 A02060 A02058 A02059 A02061 A02062 UPFLOW UPFLOW DOWNFLOW DOWNFLOW DOWNFLOW DOWNFLOW Venting Notes 1. For common vent, vent connector sizing...

Other Bryant Models