Bryant 2420 - Manual

Bryant 2420

Bryant 2420 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
Page: / 12

Table of Contents:

  • Page 2 – CAUTION; APPLICATION CONSIDERATIONS; GAP
  • Page 3 – INSTALLATION; Upflow
  • Page 6 – Fan Coil Chassis Ground; Air Flow Sensor; Flow Sensor Install
  • Page 7 – MAINTENANCE; WARNING
  • Page 9 – TROUBLESHOOTING; SAFETY HAZARD; ELECTRICAL SHOCK AND HIGH VOLTAGE; NOTE
  • Page 10 – SPECIFICATIONS AND DIMENSIONS; Table 1—Specifications and Dimensions
  • Page 11 – WARRANTY; PERFECT AIR
Loading the manual

Installation Instructions

GAPAB

PERFECT AIR

t

AIR PURIFIER FOR FAN COILS

SIZES 1620, 2020, AND 2420

NOTE

: Read the entire instruction manual before starting the

install.

TABLE OF CONTENTS

PAGE

INTRODUCTION

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

HOW IT WORKS

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SAFETY CONSIDERATIONS

1

. . . . . . . . . . . . . . . . . . . . . . . . . .

APPLICATION CONSIDERATIONS

2

. . . . . . . . . . . . . . . . . . . .

INSTALLATION

3--6

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

START--UP AND OPERATION

7

. . . . . . . . . . . . . . . . . . . . . . . . .

MAINTENANCE

7 -- 8

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TROUBLESHOOTING

9

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SPECIFICATIONS AND DIMENSIONS

10

. . . . . . . . . . . . . . . . .

WARRANTY

11

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

INTRODUCTION

Congratulations for selecting the Perfect Air

t

Air Purifier for

your home comfort system! The Perfect Air

t

Air Purifier is

proven to remove and kill airborne germs and allergens, including

viruses, bacteria, and mold spores. The Perfect Air

t

Air Purifier

is a cornerstone of Bryant’s Healthy Home Solutions for

providing healthier, cleaner air in your home.

HOW IT WORKS

The Perfect Air

t

Air Purifier provides extremely high filtration

performance while killing captured contaminants, including

viruses, bacteria, and mold spores. The Perfect Air

t

Air Purifier

treats the entire air--stream through a state of the art, three--stage

process, exclusive to Bryant.
In stage one, the particles are electrically charged by a

precision--point ionization array as they enter the Perfect Air

t

Air Purifier.
In stage two, the charged particles are electrically attracted to the

air purification cartridge, which is located within an electric field.
In stage three, captured particles are killed by electrical current

flow and ion bombardment.

The Perfect Air

t

Air Purifier is CSA certified for shock and

electrical fire hazard only.
La Perfect Air

t

Air Purifier certification CSA vise uniquement

les risques de choc electrique et.

A06367

Fig. 1

---

GAPAB Unit

SAFETY CONSIDERATIONS

Improper

installation,

adjustment,

alteration,

service,

maintenance, or use can cause explosion, fire, electrical shock or

other conditions which may cause personal injury or property

damage. Consult a qualified installer, service agency, or your

distributor or branch for information or assistance. The qualified

installer or agency must use factory authorized kits or accessories

when modifying this product. Refer to the individual instructions

packaged with the kits or accessories when installing.
Follow all safety codes. Wear safety glasses and work gloves.

Have a fire extinguisher available.

Read these instructions

thoroughly and follow all warning or cautions attached to the

unit. Consult local building codes and National Electrical Code

(NEC) for special requirements.
It is important to recognize safety information. This is the
safety--alert symbol

. When you see this symbol on the unit

and in instructions or manuals, be alert to the potential for

personal injury. Understand the signal words DANGER,

WARNING, and CAUTION. These words are used with the

safety--alert symbol.

DANGER identifies the most serious

hazards which

will

result in severe personal injury or death.

WARNING signifies hazards which

could

result in personal

injury or death. CAUTION is used to identify unsafe practices

which

may

result in personal injury or product and property

damage. NOTE is used to highlight suggestions which

will

result

in enhanced installation, reliability, or operation.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - CAUTION; APPLICATION CONSIDERATIONS; GAP

2 PERSONAL INJURY HAZARD Failure to follow this caution may result in personal injury.Ozone in concentrations above 0.05 PPM may be hazardous to health.Des concentrations d’ozone superieures a 0.05 PPM peuvent etre nocives pour la sante. CAUTION ! APPLICATION CONSIDERATIONS The Perfect Air t Air Pur...

Page 3 - INSTALLATION; Upflow

3 INSTALLATION Step 1 — Check Perfect Air t Air Purifier Components CUT HAZARD Failure to follow this caution may result in personal injury.Sheet metal parts may have sharp edges or burrs. Use care and wear appropriate protective clothing and gloves when handling parts. CAUTION ! a. Carefully remove...

Page 6 - Fan Coil Chassis Ground; Air Flow Sensor; Flow Sensor Install

6 TO FAN COIL FIELD POWER CONNECTION FUSED POWER CONNECTOR LEADS FROM INSTALLATION COMPONENTS (IN BAG ATTACHED TO POWER CORD) AIR PURIFIER POWER CORD TO FAN COIL FIELD POWER CONNECTION TO L2 FIELD POWER SUPPLY TO L1 FIELD POWER SUPPLY 5 AMP IN-LINE FUSES GROUND: ATTACH TO FAN COIL GROUND (CHASSIS) C...

Other Bryant Models

All Bryant Other