Broan Ql100 Series - Manual

Broan Ql100 Series

Broan Ql100 Series – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
Page: / 12

Table of Contents:

  • Page 2 – FiGure 1; horiZontal discharGe; FiGure 2; vertical discharGe; FiGure 3
  • Page 5 – service Parts; descriPtion
  • Page 6 – WarrantY; Broan one Year liMited WarrantY; Broan-nutone canada
  • Page 7 – campana de cocina serie Ql100; PREVISTO PARA COCINAR DOMÉSTICO SOLAMENTE.
  • Page 8 – FiGura 1; descarGa horiZontal; FiGura 2; descarGa vertical usando; descarGa vertical usando
  • Page 9 – PreParacion; refiérase a la FIGURA 1; instalación; refiérase a la FIGURA 5.
  • Page 11 – PieZas de servicio; codiGo
  • Page 12 – Garantia; Garantia Broan liMitada Por un aÑo
Loading the manual

installation instructions

read & save these instructions!

Ql100 series range hood

iMPortant saFetY instructions

WarninG – to reduce the risK oF Fire, electric shocK,

or inJurY to Persons, oBserve the FolloWinG:

1. Use this unit only in the manner intended by the manufacturer.

If you have questions, contact the manufacturer at the address

or telephone number listed in the warranty.

2. Before servicing or cleaning unit, switch power off at service

panel and lock service panel to prevent power from being

switched on accidentally. When the service disconnecting means

cannot be locked, securely fasten a prominent warning device,

such as a tag, to the service panel.

3. Installation work and electrical wiring must be done by a qualified

person(s) in accordance with all applicable codes and standards,

including fire-rated construction codes and standards.

4. Sufficient air is needed for proper combustion and exhausting

of gases through the flue (chimney) of fuel burning equipment

to prevent backdrafting. Follow the heating equipment manufac

-

turer’s guideline and safety standards such as those published

by the National Fire Protection Association (NFPA), and the

American Society for Heating, Refrigeration and Air Conditioning

Engineers (ASHRAE), and the local code authorities.

5. When cutting or drilling into wall or ceiling, do not damage

electrical wiring and other hidden utilities.

6. Ducted fans must always be vented to the outdoors.

7. Use with approved cord-connection kit only.

8. To reduce the risk of fire, use only metal ductwork.

to reduce the risK oF a ranGe toP Grease Fire:

1. Never leave surface units unattended at high settings. Boilovers

cause smoking and greasy spillovers that may ignite. Heat oils

slowly on low or medium settings.

2. Always turn hood ON when cooking at high heat or when cook

-

ing flaming foods.

3. Clean ventilating fans frequently. Grease should not be allowed

to accumulate on fan or filter.

4. Use proper pan size. Always use cookware appropriate for the

size of the surface element.

to reduce the risK oF inJurY to Persons in the event

oF a ranGe toP Grease Fire, oBserve the FolloW-

inG*:

1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or

metal tray, then turn off the burner. BE CAREFUL TO PREVENT

BURNS. If the flames do not go out immediately, EVACUATE

AND CALL THE FIRE DEPARTMENT.

2. NEVER PICK UP A FLAMING PAN - You may be burned.

3. DO NOT USE WATER, including wet dishcloths or towels - a

violent steam explosion will result.

4. Use an extinguisher ONLY if:

A. You know you have a Class ABC extinguisher, and you

already know how to operate it.

B. The fire is small and contained in the area where it start-

ed.

C. The fire department is being called.

D. You can fight the fire with your back to an exit.

* Based on “Kitchen Firesafety Tips” published by NFPA.

iMPortant saFetY instructions

1. For general ventilating use only.

do not

use to exhaust hazard-

ous or explosive materials and vapors.

2. To reduce the risk of fire or electrical shock, this range hood

should not be used with an additional speed control device.

3. To reduce the risk of shock, disconnect power before servic

-

ing.

4. To reduce the risk of fire and to properly exhaust air, be sure to

duct air outside.

Plan the installation

Recommended mounting height is 18” to 24” from the bottom of the

range hood to the top of the cooking surface.
The hood should be mounted to the bottom of a standard wall

cabinet. If the hood must be mounted directly to a wall, secure the

hood to wall studs.
All wiring must comply with local codes and the unit must be properly

grounded. The hood is connected to a 110-120vAC lighting circuit

(15 amp) in the circuit breaker or fuse box.

This range hood is “Convertible” – it may be installed as a ducted

or as a non-ducted unit.

iF the ranGe hood is to Be non-ducted:

Purchase non-ducted (duct-free) charcoal filter Model

BPQTF.

iF the ranGe hood is to Be ducted:

Ductwork can be installed vertically or horizontally.
Duct runs should be as short as possible.
Avoid the use of elbows.
Use duct tape at all joints.
Do not use duct smaller than the discharge on the hood.
For 7” round ductwork installation, use 7” round damper, Model

BP87 (97010792) Purchased damper separately.

!

intended For doMestic cooKinG onlY

!

To register this product visit:

www.broan.com

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - FiGure 1; horiZontal discharGe; FiGure 2; vertical discharGe; FiGure 3

2 ELEC. K.O. CL 12" CL 7 / 8 " 6" 7" DIA 3 / 4 " 2" 1 9" 1" 5" CUTOUT DIMENSIONS TOP VIEW BACK VIEW RANGE HOOD REMOVE BOTH 3¼" x 10" AND 7" HALF ROUND KNOCKOUTS FOR 7" DUCT ROOF CAP ROOF ADJUSTABLE ELBOW 7" ROUND DUCT 7" ROUND DAMPER SUPPLI...

Page 5 - service Parts; descriPtion

5 service Parts KeY no. Part no. descriPtion 1 R680508 7-in. Round Duct Plate 2 R99360244 Knob, White (2 req.) R99360247 Knob, Biscuit (2 req.) 3 R401658 Grille, White R401659 Grille, Biscuit 4 R740014 3¼” x 10” Damper Assembly 5 R520135 Motor 6 R566096 Lamp Socket Assembly (Short Wires) 7 R566097 L...

Page 6 - WarrantY; Broan one Year liMited WarrantY; Broan-nutone canada

Product specifications subject to change without notice. Printed in U.S.A., Rev. 02/08, Part No. 628029B WarrantY Broan one Year liMited WarrantY Broan warrants to the original consumer purchaser of its products that such products will be free from defects in materials or work - manship for a period...