Page 2 - Notes
Page 2 of 32 802006 - HT-BCS; BCSH A-AV User Manual - 09.2016 - v3.01 Notes
Page 3 - Tap Safety; HydroTap Classic; To set the tap safety setting:; The Factory setting is set at YES; To deactivate the safety; Elite Tap; Safety Lock
802006 - HT-BCS;BCSH A-AV User Manual - 09.2016- v3.01 Page 3 of 32 The safety lock feature is provided to prevent boiling water flowing if the hot lever is inadvertently operated. This function can be activated and deactivated from either the Tap or from the touch screen display (Located on the uni...
Page 4 - Tap functions
Page 4 of 32 802006 - HT-BCS; BCSH A-AV User Manual - 09.2016 - v3.01 Elite Tap: The Elite tap uses touch sensitive controls, to dispense Boiling, Chilled and Sparkling water. When operating the tap, ensure the touch surface is dry as moisture may interfere with the sensor touch control.The safety l...
Page 5 - Rotary control; Select Button
802006 - HT-BCS;BCSH A-AV User Manual - 09.2016- v3.01 Page 5 of 32 3. Tap functions MixerTap: Lifting the handle up will decrease the flow rate and lowering the handle will increase the flow rate. Raise the handle all the way up to turn the tap off.When the handle is moved towards the BLUE mark, th...
Page 6 - Tap operation; Press or pull lever; Classic Tap; Indicator; To dispense chilled water:
Page 6 of 32 802006 - HT-BCS; BCSH A-AV User Manual - 09.2016 - v3.01 Arc/Cube Tap 3. Tap operation HydroTap Classic and All-In-One taps: Depressing the “Blue” lever allows the dispensing of chilled water. Pulling forward the Blue lever allows the tap to operate in a “no-touch” mode. Water will flow...
Page 8 - d the ‘Blue’ levers allows the; To dispense Sparkling water:
Page 8 of 32 802006 - HT-BCS; BCSH A-AV User Manual - 09.2016 - v3.01 Tap operation HydroTap Classic and All-In-One taps: Depressing both the ‘Red’ an d the ‘Blue’ levers allows the dispensing of Sparkling water. Pulling forward both levers allows the tap to operate in a in a “no-touch” mode. Water ...
Page 9 - Tap lights; Flashing warning light:; Blue Chilled Water Light:; Blue Lights; Red Boiling Water Light:; This indicates that the boiling water is ready.
802006 - HT-BCS;BCSH A-AV User Manual - 09.2016- v3.01 Page 9 of 32 Tap lights Warning: (All) Flashing warning light: When the indicator light flashes fast and continuous, a system fault has occurred. Check for details on the faults screen. If unable to rectify, call a qualified service agent. Blue ...
Page 10 - Filter Lights; Flashing filter lights:
Page 10 of 32 802006 - HT-BCS; BCSH A-AV User Manual - 09.2016 - v3.01 Filter light: Classic; Elite & AIO Filter Light Off: This indicates the filter is operating within its normal specified lifespan. Filter Change light flashing slowly: The light will flash slowly when the filter is due for rep...
Page 11 - Safety Sensor Calibration; Turn the power OFF
802006 - HT-BCS;BCSH A-AV User Manual - 09.2016- v3.01 Page 11 of 32 Light intensity varies from site to site, therefore it is recommended that a re-calibration be performed at the time of the installation. All direct natural sun light must be shaded from the HydroTap, during the calibration. This c...
Page 12 - LCD Screen
Page 12 of 32 802006 - HT-BCS; BCSH A-AV User Manual - 09.2016 - v3.01 Note: When selecting Menu options, the screen will revert to the main menu, if the screen remains inactive for a period, in excess of 10 seconds. Zip HydroTap introduces a ‘TOUCH’ screen for easy setup and operation adjustment. (...
Page 13 - LCD Screen Menu; Main Menu
802006 - HT-BCS;BCSH A-AV User Manual - 09.2016- v3.01 Page 13 of 32 3 LCD Screen Menu Main Menu Sub Menu Sub Menu Options Section Language • English A • Product Info• System Faults • Event Log • Product serial no. • Lists B Information Installation • Filter Flush• Filter Reset• Boiling Calibration ...
Page 14 - A Set Language
Page 14 of 32 802006 - HT-BCS; BCSH A-AV User Manual - 09.2016 - v3.01 Language options will be available in some overseas markets A Set Language B System Information In this section, you can find your product serial number , check system fault messages or view the event logs of your product. LCD Sc...
Page 15 - C Install; Run at least 10 Ltrs of; LCD Screen operation - Section C
802006 - HT-BCS;BCSH A-AV User Manual - 09.2016- v3.01 Page 15 of 32 C Install Have a 10L bucket or similar container (not supplied) at the ready to hold a quantity of water that will be ejected while the Filter Flush Mode is in operation. Open the filter access door on the front of the HydroTap and...
Page 17 - When fitting a new gas bottle, it is important to purge the gas lines.
802006 - HT-BCS;BCSH A-AV User Manual - 09.2016- v3.01 Page 17 of 32 6. - Lux Sensor Calibration 1. Press [MENU] for main menu.2. Press [Install] . 3. Press [Lux Sensor Calibration] 4. The lights on the Tap head will flash to confirm calibration. 5. Check for correct tap operation by selecting ‘Lux ...
Page 18 - If the undersink unit is operating near 35
Page 18 of 32 802006 - HT-BCS; BCSH A-AV User Manual - 09.2016 - v3.01 Pump anti cavitation mode: This feature sends two electric pulses every 5minutes to the pump. This prevents the build up of air bubbles inside the pump and ensures an even flow of hot water at the tap. Power Pulsing mode: This is...
Page 19 - Note; In Australia call a licensed electrician, plumber,or Zip office on; D Service; This section is reserved for service technicians only; E Security; To set a password; Enter a 4 digit password; LCD Screen operation - Section E; To change a password; Enter your old 4 digit password
802006 - HT-BCS;BCSH A-AV User Manual - 09.2016- v3.01 Page 19 of 32 Note : In Australia call a licensed electrician, plumber,or Zip office on 1800-638-633, for assistance, service, spare parts, or enquiries. D Service LCD Screen operation - Section D This section is reserved for service technicians...
Page 20 - g I; nstructions
Page 20 of 32 802006 - HT-BCS; BCSH A-AV User Manual - 09.2016 - v3.01 F Communication - WiFi (Select models) This section allows the user to use WiFi to monitor the product remotely. 1. From the Home screen Press [Menu]. Then [Comm’s] 2. Enter your 4 digit password to access the WiFi set up. 3. Fol...
Page 21 - Set Temperature
802006 - HT-BCS;BCSH A-AV User Manual - 09.2016- v3.01 Page 21 of 32 1. Press the [MENU] button for main menu.2. Press the [Setting] button. 3. Press the [Date/Time] button. 4. Choose 12 hour mode or 24 hour mode by pressing the square button. The selected mode will be displayed in dark grey colour ...
Page 22 - LCD Screen operation - Section G; To edit the filter life:; Filter; The filter life may be set as a; To edit the filter usage:
Page 22 of 32 802006 - HT-BCS; BCSH A-AV User Manual - 09.2016 - v3.01 3. LCD Screen operation - Section G To edit the filter life: 1. Press the [MENU] button for main menu.2. Press the [Setting] button.3. Press the [Filter] button.4. Press the [Int / Ext Filter Life] button. 5. To change filter lif...
Page 24 - Press Group 1 or Group 2 option; Individual days set screen; Any attempt, during OFF mode, to dispense water, will bring the unit
Page 24 of 32 802006 - HT-BCS; BCSH A-AV User Manual - 09.2016 - v3.01 LCD Screen operation - Section G 1. Press Group 1 or Group 2 option 2. Press button and then scroll Up or Down to enable / disable the group set. When the enable box is ticked, this allows each individual day to have an “On/Off ”...
Page 25 - To Enable or Disable the safety on the tap
802006 - HT-BCS;BCSH A-AV User Manual - 09.2016- v3.01 Page 25 of 32 Safety LCD Screen operation - Section G B C A C * To set the tap safety setting: • Press [MENU] button for main menu. • Press [Setting] button.• Press [Safety] button.• Press button - YES to allow the safety setting to be changed o...
Page 28 - Air Inlet Filter; For best performance the unit should only be operated with a clean; Filter Maintenance
Page 28 of 32 802006 - HT-BCS; BCSH A-AV User Manual - 09.2016 - v3.01 Air Inlet Filter The Zip HydroTap air filter is conveniently located on the outside of the condenser. The filter screen is a sliding fit in the plastic housing on the side of the under sink unit. The screen may be removed for cle...
Page 30 - Home Menu Icons; °C but may; BOILING
Page 30 of 32 802006 - HT-BCS; BCSH A-AV User Manual - 09.2016 - v3.01 Home Menu Icons Safety switch is LOCKED. The HydroTap will not dispense any Boiling water.See page 3 for safety switch operation Safety switch is UNLOCKED. Boiling water may be dispensed. See page 7 for tap operation details Slee...
Page 32 - Head Office; Contact Details
Page 32 of 32 802006 - HT-BCS; BCSH A-AV User Manual - 09.2016 - v3.01 The terms “Zip” and “HydroTap” are registered trade marks of Zip Heaters (Aust) Pty Ltd. Zip products described in this publication are manufactured under one or more of the following patents: AU675601, AU637412, AU635979, GB0422...