Page 2 - Important Safety Information
2 Guide to Use the instructions The following symbols will be found in the text to guideyou throughout the Instructions: Safety Instructions Step by step instructions for an operation Hints and Tips Environmental Information Important Safety Information You MUST read these warnings carefully before ...
Page 3 - Description of the Hob; For the User; Contents; For the Installer
3 Description of the Hob This appliance complies with the following E.E.C. Directives: * 73/23 - 90/683 (Low VoltageDirective); * 93/68 (General Directives); * 89/336 (Electromagnetical Compatibility Directive) ; * 90/396 (Gas Appliances) , and subsequent modifications For the User Contents For the ...
Page 4 - Operation; Hob burners
4 Operation A - Burner cap B - Burner crown C - Ignition electrode Burner minimum maximum diameter diameter Large (rapid) 180 mm 260 mm Medium (semi-rapid) 120 mm 220 mm Small (auxiliary) 80 mm 160 mm Hob burners To light a burner: z turn the relevant control knob anticlockwise to themaximum positio...
Page 5 - The Hob Top; Maintenance and Cleaning
5 Before any maintenance or cleaning can becarried out, you must DISCONNECT the hob from the electricity supply. The hob is best cleaned whilst it is still warm, as spillagecan be removed more easily than if it is left to cool. The Hob Top Regularly wipe over the hob top using a soft cloth wellwrung...
Page 6 - Something Not Working?; Service and Spare Parts
6 Something Not Working? If the hob is not working correctly, please carry out the following checks before contacting your local Zanussi ServiceForce Centre. IMPORTANT : If you call out an engineer to a fault listed below, or to repair a fault caused by incorrect use or installation, a charge will b...
Page 7 - Zanussi Guarantee conditions; Customer Care Department; Guarantee Conditions
7 Zanussi Guarantee conditions We, Zanussi, undertake that if, within 24 months of thedate of the purchase, this Zanussi appliance or any partthereof is proved to be defective by any reason only offaulty workmanship or materials, we will, at our option,repair or replace the same FREE OF ANY CHARGE f...
Page 8 - Instructions for the Installer; Engineers technical data
8 Rear Left Burner (semi rapid) Heat Input 2.0 kW (6824 BTU/HR) Front Left Burner (rapid) Heat Input 3.0 kW Natural gas (10236 BTU/HR) 2.8 kW L.P.G. (9554 BTU/HR) Rear Right Burner (semi rapid) Heat Input 2.0 kW (6824 BTU/HR) Front Right Burner (auxiliary) Heat Input 1.0 kW (3412 BTU/HR) Instruction...
Page 9 - Important safety requirements; Provision for ventilation
9 Important safety requirements 650 mm 400 mm 400 mm 100 mm 50 mm 50 mm 55 mm 600 mm 700 mm 400 mm 100 mm 400 mm 50 mm 55 mm 50 mm I CLEARANCES REQUIRED WHEN FITTING THE HOB WITHOUT A COOKER HOOD ABOVE CLEARANCES REQUIRED WHEN FITTING THE HOB WITH A COOKER HOOD ABOVE FO 0813 FO 0812 700 mm This hob ...
Page 10 - Gas Connection; Installation; Cut Out Size
10 A) End of shaft with nut B) Washer C) Elbow FO 0814 Gas Connection Connection to the gas supply should be with either rigidor semi-rigid pipe, i.e. steel or copper.The connection should be suitable for connecting to RC1/2 (1/2 BSP male thread).When the final connection has been made, it is essent...
Page 11 - Fitting the Hob into the worktop; Building In
11 FO 0763 FO 0764 FO 1013 2 3 FO 0199 a Fitting the Hob into the worktop ) Carry out the building in of the hob as follows: • put the seals supplied with the hob, on the edges of the cut out taking care that the sealsmeet without overlapping; • place the hob in the cut out, taking care that it is c...
Page 12 - Electrical connections; Permanent Connection
12 Electrical connections Any electrical work required to install this hobshould be carried out by a qualified electrician orcompetent person, in accordance with the currentregulations. THIS HOB MUST BE EARTHED. The manufacturer declines any liability should thesesafety measures not be observed. Thi...
Page 13 - Fault Finding; Preliminary Electrical Systems Check; Wiring Diagram
13 Fault Finding Preliminary Electrical Systems Check A. EARTH CONTINUITY CHECK - Appliance must be electrically disconnected - meter set on Ω (Ohms) x 1 scale and adjust zero if necessary.a) Test leads from any appliance earth point to earth pin on plug. Resistance should be less than 0.1 Ω (Ohm), ...
Page 14 - Ignition System / Gas Ignition
14 Ignition System / Gas Ignition YES Check plug top fuseandreplace if necessary Check polarity andearth continuity ofsupply point Check earth continuityof appliance Ignitor does not spark Check fitting of burners Check position of theelectrode Check by passs i m m e r Light burner manually Check ga...
Page 15 - Conversion from Natural Gas to LPG; To adjust the gas rate; Commissioning
15 Conversion from Natural Gas to LPG IMPORTANT The replacement/conversion of the gas hob should onlybe undertaken by a competent person. It is important to note that this model is designed for usewith natural gas but can be converted for use with butaneor propane gas providing the correct injectors...