Page 2 - Important Safety Information
2 This appliance complies with the following E.E.C. Directives: * 73/23 - 90/683 (Low VoltageDirective); * 93/68 (General Directives); * 89/336 (Electromagnetical Compatibility Directive) ; * 90/396 (Gas Appliances) , and subsequent modifications Guide to Use the instructions The following symbols w...
Page 3 - Contents; For the User; Description of the Hob
3 Contents For the User For the Installer Important Safety Information 2 Description of the Hob 3 Operation 4 Maintenance and Cleaning 4 Something Not Working? 5 Service and Spare Parts 5 Customer Care Department 6 Guarantee Conditions 6 Engineers technical data 9 Installation 10 Important Safety Re...
Page 4 - Operation; Hob Burners; Maintenance and Cleaning; The Hob Top
4 Operation Hob Burners To light a burner: l turn the relevant control knob anticlockwise to maximum position; l at the same time push the electric ignition pushbutton which is marked by a little spark; l then adjust the flame as required. If the burner does not ignite, turn the control knob to zero...
Page 6 - Zanussi Guarantee conditions; Exclusions; European Guarantee; Guarantee Conditions; Customer Care Department
6 Zanussi Guarantee conditions We, Zanussi, undertake that if, within 24 months of the date of the purchase, this Zanussi appliance or any part thereof is proved to be defective by any reason only of faulty workmanship or materials, we will, at our option, repair or replace the same FREE OF ANY CHAR...
Page 7 - ZANUSSI SERVICE FORCE
7 ZANUSSI SERVICE FORCE To contact your local Zanussi Service Force Centre telephone 08705 929 929 CHANNEL ISLANDS GUERNSEY Guernsey Electricity PO Box 4 Vale, Guernsey Channel Islands JERSEY Jersey Electricity Company PO Box 45 Queens Road St Helier Jersey Channel Islands JE4 8NY SCOTLAND ABERDEEN ...
Page 9 - Instructions for the Installer; Engineers technical data
9 BURNER RAPID SEMI-RAPID AUXILIARY (large) ( m e d i u m ) (small) POSITION MAX MIN MAX MIN MAX MIN NOMINAL THERMAL POWER kW 3 . 0 0 . 6 5 2 . 0 0 . 4 5 1 . 0 0 . 3 3 NOMINAL FLOW RATE m 3 /h 0 . 2 8 6 0 . 0 5 7 0 . 1 9 0 0 . 0 3 8 0 . 0 9 5 0 . 0 2 8 NOZZLE REFERENCE 1 1 9 A d j u s t . 9 6 A d j ...
Page 10 - Important safety requirements; Location; Installation
10 700 mm 400 mm 100 mm 400 mm 50 mm 55 mm 50 mm 650 mm 400 mm 400 mm 100 mm 50 mm 50 mm 55 mm 600 mm FO 0812 FO 0813 Important safety requirements This hob must be installed in accordance with the Gas Safety (Installation and Use) Regulations (Current Edition) and the IEE Wiring Regulations (Curren...
Page 11 - Building In
11 ON/OFF SWITCH FLEXOUTLET ON/OFF SWITCH FLEXOUTLET FO 0763 FO 0764 1 2 Dimensions are given in mm. Building In Building over a cupboard or drawer If the hob is to be installed above a cupboard or drawer it will be necessary to fit a heat resistant board below the base of the hob on the underside o...
Page 12 - Permanent Connection; Electrical connections; Fitting the Hob into the worktop
12 Permanent Connection In the case of a permanent connection, it is necessary that you install a double pole switch between the hob and the electricity supply (mains), with a minimum gap of 3 mm. between the switch contacts and of a type suitable for the required load in compliance with the current...
Page 13 - Preliminary Electrical Systems
13 A. IGNITOR SWITCH B. IGNITOR UNIT B L N 0 1 2 3 4 5 6 220/240 A Wiring Diagram Fault Finding Preliminary Electrical Systems Check A. EARTH CONTINUITY CHECK - Appliance must be electrically disconnected - meter set on W (Ohms) x 1 scale and adjust zero if necessary. a ) Test leads from any applian...
Page 14 - Ignition System / Gas Ignition
14 Ignition System / Gas Ignition YES Check plug top fuse and replace if necessary Check polarity and earth continuity of supply point Check earth continuity of appliance Ignitor does not spark Check fitting of burners Check position of the electrode Check by pass simmer adjusted Light burner manual...
Page 15 - Commissioning; Conversion from Natural Gas to LPG; To adjust the gas rate
15 Commissioning When the hob has been fully installed it will be necessary to check the minimum flame setting. To do this, follow the procedure below. - Turn the gas tap to the MAX position and ignite. - Set the gas tap to the MIN flame position then turn the control knob from MIN to MAX several ti...