Page 3 - CONTENTS
TSE-P 02.01 LF 3/35 599 34 60-32 CONTENTS 1. INTRODUCTION 1.1 General characteristics 1.2 Field of application 1.3 Electronic module 1.4 Aesthetic characteristics 1.5 Structural characteristics 2. FUNCTIONAL CHARACTERISTICS 2.1 Control panel 2.2 Supplementary options 2.3 Power failure 2.4 Selection ...
Page 5 - AESTHETIC CHARACTERISTICS
TSE-P 02.01 LF 5/35 599 34 60-32 1.4 AESTHETIC CHARACTERISTICS Control panel – VERTICAL version VARIANTS ON key on right ON key on left Control panel – HORIZONTAL version VARIANTS ON key on right ON key on left
Page 6 - STRUCTURAL CHARACTERISTICS; MODULAR 45 cm
TSE-P 02.01 LF 6/35 599 34 60-32 1.5 STRUCTURAL CHARACTERISTICS Structure: MODULAR 45 cm Functionality: EVOLUTION Version: FREE-STANDING / BUILT-IN Controls: KEYS LAYOUT OF CONTROLS [ S0 ] - ON/OFF key [ S1 ] … [ S3 ] - PROGRAMME SELECTION keys [ S4 ] … [ S6 ] - PROGRAMME SELECTION and/or OPTION key...
Page 7 - FUNCTIONAL CHARACTERISTICS; CONTROL PANEL
TSE-P 02.01 LF 7/35 599 34 60-32 2. FUNCTIONAL CHARACTERISTICS 2.1 CONTROL PANEL ON/OFF KEY [ S0 ] Switches the dishwasher ON and OFF. When the LED [LD0] lights, this means that the appliance is switched on. 2.1.1 PROGRAMME AND OPTION KEYS [ S1 S2 S3 S4 S5 S6 ] Used to select a washing programme and...
Page 8 - SUPPLEMENTARY OPTIONS; POSSIBLE OPTIONS: «DELAY»
TSE-P 02.01 LF 8/35 599 34 60-32 2.2 SUPPLEMENTARY OPTIONS (factory-set) 2.2.1 POSSIBLE OPTIONS: «DELAY» & «1/2 LOAD» (if featured) Only one option can be selected at a time («DELAY» or «1/2 LOAD»), never both. If featured, the option may be associated with keys [ S4 ] or [ S5 ] or [ S6 ]. 2.2.1...
Page 9 - Switch the dishwasher ON by pressing [; CYCLE EXECUTION; Washing programme currently being performed.; END OF CYCLE
TSE-P 02.01 LF 9/35 599 34 60-32 2.4 SELECTION OF PROGRAMMES 2.4.1 SELECTING THE CYCLE (with the door closed) Switch the dishwasher ON by pressing [ S0 ]; the “POWER ON” pilot lamp lights [LD0]. The SALT and RINSE-AID LEDs [LD13 LD14] may light. Press the key for the desired programme [ S1 S2 S3 ......
Page 10 - Press one of the keys [; PROGRAMME EXECUTION; The delayed start countdown has started.
TSE-P 02.01 LF 10/35 599 34 60-32 2.5 SELECTING A PROGRAMME WITH THE DELAYED START OPTION 2.5.1 PROGRAMME SELECTION (with the door closed) Press [ S0 ] to switch the dishwasher on; the “POWER ON” LED [LD0] lights. Perform the procedure for selection of the programme / options as described in paragra...
Page 11 - SPECIFICATIONS FOR ACTUATORS AND SENSORS; COMPONENTS
TSE-P 02.01 LF 11/35 599 34 60-32 3. SPECIFICATIONS FOR ACTUATORS AND SENSORS 3.1 COMPONENTS TYPE OF COMPONENT POWER AVAILABLE TYPE OF CONTROL Wash pump Max 250W Triac & relay Drain pump Max 100W Triac & relay Washing heater Max 2100W Relay Water fill solenoid Max 10W Triac Regeneration sole...
Page 12 - OPERATION OF THE WASH / DRAIN MOTOR; MOTOR; TECHNICAL CHARACTERISTICS:; WASH / DRAIN FUNCTION
TSE-P 02.01 LF 12/35 599 34 60-32 4 OPERATION OF THE WASH / DRAIN MOTOR 4.1 WASH MOTOR CHARACTERISTICS This dishwasher is fitted with a single-phase variable-speed asynchronous motor. A tachimetric sensor, fitted to the interior of the motor, constantly monitors the speed of the motor,which is trans...
Page 13 - Head
TSE-P 02.01 LF 13/35 599 34 60-32 4.3 WASHING SYSTEM This appliance features the conventional washing system, in which the mechanical action is obtainedby the rotation of the single motor. This drives the water into the hydraulic circuit and actions the twospray arms simultaneously. DEFINITION OF TH...
Page 14 - CIRCUIT; KEY
TSE-P 02.01 LF 14/35 599 34 60-32 4.5 5. HYDRAULIC CIRCUIT KEY 1. Anti-flooding device 11. Sump 2. Anti-overflow device 12. Pressure switch 3. Fill solenoid 13. Connector siphon for anti-overflow device 4. Air-Break 14. Cutting valve sump 5. Intake valve for regeneration chamber 15. Wash motor 6. Re...
Page 15 - WATER FILL - FUNCTIONAL SYSTEM; ) Tachimetric sensor
TSE-P 02.01 LF 15/35 599 34 60-32 5.1 WATER FILL - FUNCTIONAL SYSTEM For dishwashers fitted with motors with tachimetric sensors (1.5 New Generation models), theelectronic control system is designed to control the water fill by identifying the signals received fromthe pressure switch (which thus act...
Page 17 - POW ER FAILURE DURING WATER FILL PHASE; CONTROL OF STABILITY OF WASHING WATER; Water replenisjment may take place is necessary.
TSE-P 02.01 LF 17/35 599 34 60-32 5.2.6 WATER FILL TIMEDuring the entire duration of the fill phase (i.e. from sub-phase 5.2.1 to sub-phase 5.2.4), the solenoidvalve may remain in the open position for a maximum overall time of 4 minutes. Within this period, the system detects whether the pressure s...
Page 18 - CONTROL OF DRAIN CYCLE
TSE-P 02.01 LF 18/35 599 34 60-32 5.4 CONTROL OF DRAIN CYCLE When the washing cycle ends, the appliances passes to the drain phase. In this phase, in order to ensure that the hydraulic circuit is empty before the start of the subsequentphase (water fill), a control procedure is carried out at the en...
Page 19 - SPECIAL REGENERATION CYCLE; Level set in the factory
TSE-P 02.01 LF 19/35 599 34 60-32 5.5 SPECIAL REGENERATION CYCLE With the new water softening system, the “special regeneration” process is controlled electronically,and is subdivided into 5 levels as follows: REGENERATION VALUES LEVEL INDICATION WASHING CYCLE FILL PHASES WATER HARDNESS DEFINITION L...
Page 20 - «ACTIVE» DRYING SYSTEM; The duration of the drying cycle is approximately
TSE-P 02.01 LF 20/35 599 34 60-32 6 «ACTIVE» DRYING SYSTEM The “Active Plus” drying system features a close integrated circuit with bidirectional convectivemovement ; air is drawn in from the exterior thus allowing the circulation of the inner warm air. 6.1 DEFINITION OF THE SYSTEMThe drying system ...
Page 23 - DESCRIPTION OF SAFETY FEATURES AND ALARMS; This Time-out is activated only during the water fill phases.
TSE-P 02.01 LF 23/35 599 34 60-32 7.4 DESCRIPTION OF SAFETY FEATURES AND ALARMS 7.4.1 WATER FILL TIME-OUT ALARM [A L 5] Led [ LD9 ] This Time-out is activated only during the water fill phases. Ä The control system definitively switches off the fill solenoid valve. Ä Counting of time “T” starts when...
Page 24 - The impedance of the NTC sensor is monitored constantly.
TSE-P 02.01 LF 24/35 599 34 60-32 7.4.3 ANTI-FLOODING CONTROL SYSTEM ALARM [A L 4] Leds [ LD9 ] + [ LD10 ] This control system is operative during the washing phases only, and not in the water fill phases, inwhich case is it connected to the safety device (see paragraph 7.4.1 “W ater Fill Time-out”)...
Page 27 - ELECTRICAL FUNCTIONS; CIRCUIT DIAGRAM
TSE-P 02.01 LF 27/35 599 34 60-32 8 . ELECTRICAL FUNCTIONS 8.1 CIRCUIT DIAGRAM
Page 28 - BASIC ELECTRICAL DIAGRAM
TSE-P 02.01 LF 28/35 599 34 60-32 8.2 BASIC ELECTRICAL DIAGRAM
Page 29 - Plant; Programme
T SE-P 02 .01 LF 29/35 599 34 60-32 8.3T A B L E OF W A S H IN G PROGR A M M E S T he table lis ts al l the pr o gr am m es s tor ed in mem or y. The c odes ( A , B etc.) i den tif y t he pr o gr am m es assigned ( m ax . 5) to the indiv id ual appl ia nc es . Pre- w ash M ain w ash First rinse S ec...
Page 30 - COMPONENT DIAGNOSTICS; OFF
TSE-P 02.01 LF 30/35 599 34 60-32 9. SERVICING 9.1 COMPONENT DIAGNOSTICS This test is used by service engineers only to check the efficiency of the main electrical components.To access the test procedure, it is necessary to press a combination of keys. Correct operation of thecomponents to be tested...
Page 31 - FUNCTIONAL TESTING CYCLE
TSE-P 02.01 LF 31/35 599 34 60-32 9.2 FUNCTIONAL TESTING CYCLE The functional testing cycle is an abbreviated washing programme for use by service engineers only.The testing cycle enables the engineer to check all the functions which make up a traditional washingcycle (in effect, the test simulates ...
Page 32 - CHECKING THE EFFICIENCY OF THE COMPONENTS; to the 2 Motor cables
TSE-P 02.01 LF 32/35 599 34 60-32 9.3 CHECKING THE EFFICIENCY OF THE COMPONENTS In order to facilitate testing of the components, a TEST PROCEDURE has been created showing thecontacts to which the probes of the tester should be connected and the theoretical reading for eachcomponent. 9.3.1 PROCEDURE...
Page 33 - COMPONENT CONNECTION DIAGRAM
TSE-P 02.01 LF 33/35 599 34 60-32 9.3.2 COMPONENT CONNECTION DIAGRAM