Page 4 - ii; Limited; What does this warranty cover and how long does it last?; XDC 6000 Watt Series Slave; What will Xantrex do?; How do you get service?; Toll Free North America:
ii Operating Manual for XDC Series Slave Power Supply Limited Warranty What does this warranty cover and how long does it last? This Limited Warranty is provided by Xantrex Technology, Inc. (“Xantrex”) and covers defects in workmanship and materials in your XDC 6000 Watt Series Slave Power Supply. T...
Page 5 - iii; Proof of purchase may be in any one of the following forms:; What does this warranty not cover?; another manufacturer
Release 1.0 iii Direct returns may be performed according to the Xantrex Return Material Authorization Policy described in your front panel controlled XDC product manual. For some products, Xantrex maintains a network of regional Authorized Service Centers. Call Xantrex or check our website to see i...
Page 6 - iv; Disclaimer; Product; Exclusions
iv Operating Manual for XDC Series Slave Power Supply Disclaimer Product THIS LIMITED WARRANTY IS THE SOLE AND EXCLUSIVE WARRANTY PROVIDED BY XANTREX IN CONNECTION WITH YOUR XANTREX PRODUCT AND IS, WHERE PERMITTED BY LAW, IN LIEU OF ALL OTHER WARRANTIES, CONDITIONS, GUARANTEES, REPRESENTATIONS, OBLI...
Page 7 - Model Number
Release 1.0 v Information WITHOUT LIMITING THE GENERALITY OF THE FOREGOING, UNLESS SPECIFICALLY AGREED TO BY IT IN WRITING, XANTREX a. MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN MANUALS OR OTHER DOCUMENTATION PROVIDED BY IT IN C...
Page 8 - vi; Warnings; WARNING
vi Operating Manual for XDC Series Slave Power Supply Warnings and Cautions Warnings and cautions are defined and formatted in this manual as shown below. Power Supply Safety WARNING Describes a potential hazard which could result in injury or death, or, a procedure which, if not performed correctly...
Page 9 - vii; Approvals; CE Mark
Release 1.0 vii Approvals CE Mark CE-marked units meet the following standards: • IEC 1010-1-92 including Amendments 1 and 2: • Overvoltage Category II • Permanently Connected Equipment • Pollution Degree 2 • EN50081-2-1996 Electromagnetic Generic Emission - Industrial Equivalent • EN50082-2-1995 El...
Page 10 - viii
viii Operating Manual for XDC Series Slave Power Supply TM-XDSL-01XN.book Page viii Tuesday, November 5, 2002 3:22 PM
Page 11 - ix; About This Manual; Who Should Use This Manual
Release 1.0 ix About This Manual This Operating Manual contains operating instructions for the XDC Series Slave power supplies. This power supply is based on the XDC Series of digital, programmable power supplies, with the same high level of accuracy and reliability, but specifically designed with n...
Page 13 - xi; Table of Contents; Section 2. A C Input Power
Release 1.0 xi Table of Contents About This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ixTable of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .xi Section 1. Overvie...
Page 15 - Features; Standard CANbus and RS-232 digital remote control
Release 1.0 13 Section 1. Overview The XDC series Slave power supply is designed for use in current sharing systems as a slave module connected in parallel with an XDC 6000 Watt series full digital controlled front panel unit. In such a configuration, the XDC full digital controlled front panel unit...
Page 16 - Front Panel; Slave Front Panel; Rack mount brackets
Overview Front Panel 14 Operating Manual for XDC Series Slave Power Supply Front Panel Figure 1.1 Slave Front Panel 1. Rack mount brackets 2. Handles 3. ON/OFF Switch 4. Power On status LED (green) 5. Ouput Off status LED (red) Lit when the output is disabled 6. Front panel display (vacuum fluoresce...
Page 17 - Section 2. AC Input Power
AC Input Power Front Panel Release 1.0 15 Section 2. AC Input Power WARNING Disconnect AC power from the unit before removing the connector cover. Live line voltages may be exposed when the cover is removed. WARNING A safety ground wire must be connected to the unit as shown in Figure 2.1 to ensure ...
Page 18 - AC Input Connector; AC Input Wire; AC Wire Specification for 6000 Watt units; AC Input Voltage Range
AC Input Power AC Input Connector 16 Operating Manual for XDC Series Slave Power Supply AC Input Connector The AC input connector is a standard wire clamp terminal block with 3-phase connectors and a chassis ground connector. The safety ground wire, alternatively, may be connected to the chassis usi...
Page 19 - AC Wire Input Connection
AC Input Power AC Wire Input Connection Release 1.0 17 AC Wire Input Connection See Figure 2.2, on page 18. To connect the AC input wires: 1. Ensure that the AC input cord is de-energized, and that the power switch on the front of the power supply is OFF. 2. Strip approximately 6.25 in. (160 mm) fro...
Page 20 - Attaching the AC Input Wires
AC Input Power AC Wire Input Connection 18 Operating Manual for XDC Series Slave Power Supply Figure 2.2 Attaching the AC Input Wires TM-XDSL-01XN.book Page 18 Tuesday, Novem ber 5, 2002 3:22 PM
Page 21 - Section 3. Current Sharing; Overview; Connections for Current Share Operation; Theory of
Current Sharing Overview Release 1.0 19 Section 3. Current Sharing Overview Power supplies equipped with the CANbus interface will allow current sharing between units connected in parallel. Current sharing can use a maximum of 5 supplies, including the master. All power supplies must be the same mod...
Page 22 - CANbus; CANbus Pins; Setup; The master power supply may be connected to a PC via RS-232 or GPIB.; Function
Current Sharing Overview 20 Operating Manual for XDC Series Slave Power Supply CANbus Setup The CANbus port is a one male, one female DB9 connector to support “daisy chain” connections. The CAN (Controller Area Network) is an ISO standard (ISO11898) for a serial communication network. Table 3.1 desc...
Page 23 - Current Share
Current Sharing Overview Release 1.0 21 Current Share Configuration Units are programmed in a mode such that it is already in current sharing mode on power up. This feature is not user-modifiable. Please contact the manufacturer for assistance if you wish to change this. Most configurable settings a...
Page 24 - Operation; Errors
Current Sharing Operation 22 Operating Manual for XDC Series Slave Power Supply Operation There can only be one master unit and 4 slave units current sharing. All other units will not current share. Units must have the same output ratings or they will not current share. Once a current sharing networ...
Page 25 - Appendix A. Specifications and Characteristics; Notes
Release 1.0 23 Appendix A. Specifications and Characteristics Notes • These specifications are represented over the full operating temperature range. • Nominal line input voltage assumed unless otherwise stated. • All sense lines are configured for default local operation. • All specifications are s...
Page 26 - Electrical Specifications—Summary; Specifications for 10V to 60V Models; Models
Specifications and Characteristics Electrical Specifications—Summary 24 Operating Manual for XDC Series Slave Power Supply Electrical Specifications—Summary Table A.1 Specifications for 10V to 60V Models Table A.2 Drift Specifications for 10V to 60V Models Models 10-600 20-300 30-200 40-150 60-100 O...
Page 27 - Specifications for 80V to 600V Models
Specifications and Characteristics Electrical Specifications—Summary Release 1.0 25 Table A.3 Specifications for 80V to 600V Models Table A.4 Drift Specifications for 80V to 600V Models Models 80–75 100–60 150–40 300–20 600–10 Output Ratings: Output Voltage 1 Output Current 2 Output Power 1. Minimum...
Page 28 - AC Line Input; AC Line Input Specifications
Specifications and Characteristics AC Line Input Specifications 26 Operating Manual for XDC Series Slave Power Supply AC Line Input Specifications The input to the power supply requires the following specifications. AC Line Input Voltage Operating Ranges Table A.5 AC Line Input Specifications Operat...
Page 29 - Output Performance Specifications; –103% of maximum rated voltage
Specifications and Characteristics Output Performance Specifications Release 1.0 27 Output Performance Specifications These specifications define the electrical performance specifications of the power supply output. These specifications apply to both local and remote sense configurations, except whe...
Page 30 - Typical Programming Resolution
Specifications and Characteristics Output Performance Specifications 28 Operating Manual for XDC Series Slave Power Supply Typical Programming Resolution Typical Measurement Resolution Programming Accuracy 1 Readback A ccuracy 30 Minute Drift 2 Remote Digital Interface VoltageCurrent PowerOver Volta...
Page 31 - Typical 31 kHz 62 kHz output ripple; Load Condition
Specifications and Characteristics Output Performance Specifications Release 1.0 29 8 Hour Drift Temperature Stability 1 Temperature Coefficients Switching Frequency Typical 31 kHz; 62 kHz output ripple Rise Time 5 to 95% step in output voltage. Fall Time For a programmed 95% to 5% step in output vo...
Page 32 - Maximum deviation as a percentage of rated output voltage.; Mode
Specifications and Characteristics Output Performance Specifications 30 Operating Manual for XDC Series Slave Power Supply Time Delay From Output Enable Until Output Stable 2 s maximum(Within regulation envelope) Output Hold-Up Time – Power Off Minimum 4 ms (at full load) Output Hold-Up Time – Sourc...
Page 33 - Environmental Specification; Thermal; International Approvals
Specifications and Characteristics Environmental Specification Release 1.0 31 Environmental Specification Thermal Specification Humidity Specification International Approvals CE-marked units meet: EN61010-1, EN50081-2 and EN500082-2. CSA C/US certified to C22.2 No 1010.1 and UL3111-1. Meets USA EMC ...
Page 34 - Mechanical Specification; Weight; Power Supply Dimensions
Specifications and Characteristics Mechanical Specification 32 Operating Manual for XDC Series Slave Power Supply Mechanical Specification Weight Approx. 75 lb. (34 kg) for 10 V-600 A unit, without packaging Size Figure A.1 Power Supply Dimensions TM-XDSL-01XN.book Page 32 Tuesday, Novem ber 5, 2002...
Page 36 - Xantrex Technology Inc.
Xantrex Technology Inc. 8999 Nelson Way Burnaby, British Columbia Canada V5A 4B5604 422 2777 Tel604 420 2145 Fax800 670 0707 Toll Free North [email protected] TM-XDSL-01XN PRINTED IN CANADA TM-XDSL-01XN.book Page 34 Tuesday, Novem ber 5, 2002 3:22 PM