Page 2 - WIRING DIAGRAMS; IS A FACTORY-INSTALLED JUMPER

2 WIRING DIAGRAMS FOR ONE ELEMENT FURNACES FAN DELAY OFF COMBINATION Fan and Heater Loads SEPARATE Fan and Heater Loads ONE POLE WIRING M2 M1 To 1st element & fan H H To 24 VAC wall thermostat (One Timing) 24A34-1 / -2 TWO POLE WIRING M2 M1 To fan H H To 24vAC wall thermostat (One Timing) 24A34-...

Page 3 - FOR FOUR ELEMENT FURNACES; FOR FIVE ELEMENT FURNACES; COMBINATION Fan and Heater Loads

3 WIRING DIAGRAMS FOR FOUR ELEMENT FURNACES COMBINATION Fan and Heater Loads SEPARATE Fan and Heater Loads TWO POLE WIRING M8 M7 To 4th element H H To 24vAC wall thermostat (Two Timings) 24A34-6 M2 M1 To fan & 1st element M4 M3 To 2nd element H H TWO POLE M6 M5 To 3rd element SINGLE-STAGE Room T...

Page 4 - FOR SIX ELEMENT FURNACES; FOR SEVEN ELEMENT FURNACES

TWO POLE M8 M7 To 5th element H H To W1 of 24vAC wall thermostat (Two Timings) 24A34-6 M2 M1 To fan & 1st element M4 M3 To 4th element H H TWO POLE M6 M5 To common of 24v transformer To 7th element To fan interlock To 6th element To W2 of 24vAC wall thermostat TWO POLE M8 M7 H H (Two Timings) 24...