Page 2 - xi
Unless otherwise specified, all commercial cooking equip-ment manufactured by WELLS MFG. CO. is warranted against defects in materials and workmanship for a period of one year from the date of original installation or 18 months from the date of shipment from our factory, whichever comes first, and i...
Page 3 - Thank You for purchasing this Wells Manufacturing Co. appliance.; TABLE OF CONTENTS
WARRANTY xi SPECIFICATIONS 1 FEATURES & OPERATING CONTROLS 2 PRECAUTIONS & GENERAL INFORMATION 6 AGENCY LISTING INFORMATION 7 INSTALLATION 8 OPERATION 12 CLEANING INSTRUCTIONS 16 MAINTENANCE SCHEDULES 19 MSDS (Ansulex Low pH) 22 TROUBLESHOOTING SUGGESTIONS 24 PARTS & SERVICE 25 CUSTOMER ...
Page 4 - FEATURES & OPERATING CONTROLS; Fig. 1 Ventilator Section Operating Features & Controls
FEATURES & OPERATING CONTROLS Fig. 1 Ventilator Section Operating Features & Controls 2 28 28 19 16 23 a15 a11 53 56 18 9 8 38 VENTILATOR CONTROL PANELsee pages 4 & 5 GRIDDLE CONTROL PANELsee pages 4 & 5 18 16 23 WARMER CONTROLSsee pages 4 & 5 PULL HANDLE TO ACTIV ATE FIRE SUPP R...
Page 5 - FIRED; VENTILATOR SECTION
ITEM 1. a6. 8. 9. a10. a11. 12. a15. 16. 18. 19. 22. 23. 28. a31. 38. 40. 41. 42. 43. 44. 53. 56. DESCRIPTION NAMEPLATE FIRE SUPPRESSION AGENT TANK (1.5 gal.) ADJUSTABLE (FRONT) LEG RIGID (REAR) CASTER MANUAL PULL STATION FUSIBLE LINKS LOWER REAR ACCESS PANEL DISCHARGE NOZZLE GREASE BAFFLE PRE-FILTE...
Page 7 - GRIDDLE SECTION CONTROLS
ITEM V.01 V.02 V.03 V.04* V.05* V.06* G.01 G.02 W.01 W.02 W.03 W.04 DESCRIPTION POWER SWITCH POWER ON INDICATOR CHECK FILTERS ALARM INDICATOR REPLACE PREFILTER ALARM INDICATOR REPLACE FILTER PACK ALARM INDICATOR SERVICE REQUIRED ALARM INDICATOR GRIDDLE TEMPERATURE CONTROL INDICATOR LIGHT WARMER TEMP...
Page 8 - Fire suppression system and all associated components must; Authorized Ansul® Distributor ONLY; If a remote pull station is installed, both rear casters (9); PRECAUTIONS AND GENERAL INFORMATION
NOTE: Fire suppression system and all associated components must only be serviced by an authorized Ansul® Distributor. All setup, charging, repair and/or adjustment of the fire suppression system must be performed by an Authorized Ansul® Distributor ONLY . IMPORTANT: If a remote pull station is inst...
Page 9 - AGENCY LISTING INFORMATION; REPLACE PREFILTER; cooking appliance; PRECAUTIONS AND GENERAL INFORMATION (continued); Installation Instructions
AGENCY LISTING INFORMATION OPERATIONAL NOTES: REPLACE PREFILTER and REPLACE FILTER PACK indicator lights provide a timely warning that a system shut-down is imminent. The actual time between the indicator light coming on and the loss of cooking appliance power will depend upon the cooking conditions...
Page 10 - ANSULEX® Low pH; minimum of 8 ft
INSTALLATION NOTE: DO NOT discard the carton or other packing materials until you have inspected the appliance for hidden damage and tested it for proper operation. Refer to SHIPPING DAMAGE CLAIM PROCEDURE on the inside front cover of this manual. WARNING: Risk of personal injury Installation proced...
Page 11 - SERVICE TECHNICIAN INSTALLATION NOTES; WARRANTY REGISTRATION; ELECTRICAL INSTALLATION; THE; DANGER
SERVICE TECHNICIAN INSTALLATION NOTES An Ansul® technician must charge and arm the fire suppression system before the ventilator blower will operate. See page 10. Installation and start up must be performed by an Authorized Installation Company. Installer must complete the WARRANTY REGISTRATION form...
Page 12 - FIRE SUPPRESSION SYSTEM INSTALLATION; Ansul®; Call your Authorized Ansul® Distributor immediately for; FIRE HAZARD; Recharging and
INSTALLATION (continued) FIRE SUPPRESSION SYSTEM INSTALLATION 1. Any REMOTE MANUAL PULL STATION must be installed by an authorized ANSUL® distributor in accordance with the AUTHORITY HAVING JURISDICTION. NOTE: If a REMOTE MANUAL PULL STATION is installed, moving the unit for servicing will cause the...
Page 13 - FILTERS INSTALLATION
FILTERS INSTALLATION 1. FILTER PACK: Ships installed in the hood. If the FILTER PACK is not in position, the CHECK FILTERS indicator will light. If the FILTER PACK becomes clogged, the REPLACE FILTER PACK indicator will glow. To install the FILTER PACK: Position the filter pack with the charcoal por...
Page 14 - Spilled Oil; DO NOT OPERATE UNLESS; GREASE TROUGH AND GREASE CUP INSTALLATION; Fig. 7 Roll Warmer Drawer Pan Installation
INSTALLATION (continued) WARNING Slipping / Falling Hazard Spilled Oil DO NOT OPERATE UNLESS THE GREASE CUP TROUGH AND GREASE DRAWER ARE INSTALLED. Oil and moisture will drip onto the floor and falls may result. Death or serious injury may result from slipping and falling GREASE TROUGH AND GREASE CU...
Page 16 - GRIDDLE OPERATION; PREPARING THE GRIDDLE SURFACE; RECOMMENDED GRILLING TIMES AND TEMPERATURES; PRODUCT TEMPERATURE oF TIME
OPERATION (continued) CAUTION: Hot Surface Exposed surfaces can be hot to the touch and may cause burns. As manufactured, the steel surface of your Wells griddle has microscopic pores. It is important to fill these pores with oil in order to provide a hard, non-stick cooking surface. Because the mic...
Page 17 - OPERATING CHART FOR DRAWER WARMERS
OPERATION (continued) CAUTION: Hot Surface Exposed surfaces can be hot to the touch and may cause burns. NOTE: The chart below is intended as a guide ONLY. Your own experience with this appliance, type of foods and method of operation will enable you to determine the temperature control and air vent...
Page 18 - CLEANING INSTRUCTIONS; not; covered by; GRIDDLE DAILY CLEANING; Set temperature control to 220oF. Allow the
CLEANING INSTRUCTIONS CAUTION: Electric Shock Hazard Disconnect appliance from electric power before cleaning. CAUTION: Hot Surface Exposed surfaces can be hot to the touch and may cause burns. Allow appliance to cool before cleaning. IMPORTANT: DO NOT spill or pour water into controls, control pane...
Page 20 - VENTILATOR MONTHLY CLEANING; TOOLS:
CLEANING INSTRUCTIONS CAUTION: Electric Shock Hazard Disconnect appliance from electric power before cleaning. CAUTION: Hot Surface Exposed surfaces can be hot to the touch and may cause burns. Allow appliance to cool before cleaning. IMPORTANT: Never allow PRE-FILTER or FILTER PACK to get wet. DO N...
Page 21 - MAINTENANCE SCHEDULES; STANDARD FOR; Procedures for
MAINTENANCE SCHEDULES USE AND MAINTENANCE SHALL BE IN ACCORDANCE WITH THE STANDARD FOR VENTILATION CONTROL AND FIRE PROTECTION OF COMMERCIAL COOKING OPERATIONS , N.F.P.A 17A & N.F.P.A. 96 (current editions). DANGER Fire Hazard FAILURE TO PROPERLY CLEAN AND MAINTAIN THIS EQUIPMENT CAN CAUSE A FIR...
Page 24 - ANSUL; MATERIAL SAFETY DATA SHEET; SECTION 1 - IDENTITY
22 ANSUL ® ANSUL INCORPORATEDMARINETTE, WI 54143-2542 MATERIAL SAFETY DATA SHEET ANSULEX Low pH QUICK IDENTIFIER (In Plant Common Name) Manufacturer’sName: EmergencyTelephone No.: ANSUL INCORPORATED CHEMTREC (800) 424-9300 or (703) 527-3887 Prepared By: Address: One Stanton Street, Marinette, WI 541...
Page 26 - TROUBLESHOOTING SUGGESTIONS; CHECK FILTERS; SUGGESTED ACTION; There are no user serviceable components in the appliance.
TROUBLESHOOTING SUGGESTIONS SYMPTOM Ventilator blower won’t run Ventilator blower won’t run — buzzer sounding Ventilator blower runs momentarily, shuts down. CHECK FILTERS light on REPLACE PREFILTER light on. REPLACE FILTER PACK light on SERVICE REQUIRED light on Griddle won’t heat One or more gridd...
Page 27 - service personnel only.; Wells Manufacturing Co.; CUSTOMER SERVICE DATA; Ø 3Ø
DESCRIPTION SERVICE PART NO. PRE-FILTER 22618 PRE-FILTER CAGE 22683 FILTER PACK (HEPA + CHARCOAL) 22619 GREASE BAFFLE 22684 LEG KIT 22649 CASTER KIT 22650 GREASE CUP 22626 SCRAPER, GROOVED GRIDDLE 20651 DRAWER PAN, REPLACEMENT 21488 RACK, HUMITROL 20624 WELLS BULLETIN (ANSUL® PARTS LIST) 303331 NOTE...