Page 2 - Attention: Danger of injury by injection!; Airless units develop extremely high spraying pressures.; PE
2 ProSpray 3.34 GB Warning! Never put your fingers, hands or any other parts of the body into the spray jet! Never point the spray gun at yourself, other persons or animals. Never use the spray gun without safety guard. Do not treat a spraying injury as a harmless cut. In case of injury to the skin ...
Page 3 - Contents
ProSpray 3.34 3 GB Contents Contents Page 1. Safety regulations for Airless spraying ....................... 4 1.1 Earthing instructions......................................................... 5 2. General view of application ........................................... 6 2.1 Application...............
Page 4 - Safety Regulations; Safety regulations for Airless
4 ProSpray 3.34 GB Safety Regulations 1. Safety regulations for Airless spraying This manual contains information that must be read and understood before using the equipment. When you come to an area that has one of the following symbols, pay particular attention and make certain to heed the safegua...
Page 5 - Earthing Instructions; Work or repairs at the electrical equipment:; is assumed for incorrect installation.
ProSpray 3.34 5 GB Safety regulations General view of application HAZARD: EXPLOSION HAZARD DuE TO INCOMPATIBLE MATERIALS Will cause severe injury or property damage.PREVENTION : • Do not use materials containing bleach or chlorine. • Do not use halogenated hydrocarbon solvents such as methylene chlo...
Page 6 - General view of application; Application; Description of unit; Airless process; Materials
6 ProSpray 3.34 GB General view of application Description of unit 2. General view of application 2.1 Application 2.2 Coating materials Processible coating materials i Pay attention to the Airless quality of the coating materials to be processed. Dilutable lacquers and paints or those containing sol...
Page 8 - Technical data; Volume flow at 12 MPa; Transportation; Pushing or pulling the unit; Transportation in vehicle; Starting operation; separating oil; EasyGlide prevents increased wear and tear to
8 ProSpray 3.34 GB Description of unit Starting operation 3.5 Technical data Voltage: 220~240 Volt AC, 50/60 Hz Max. current consumption: 8.5 A @ 230VAC Power cord: 3 x 1.5 mm 2 – 6 m Acceptance capacity: 1955 Watt Max. operating pressure: 221 bar (22.1 MPa) Volume flow at 12 MPa (120 bar) with wate...
Page 9 - Control Panel Indicators; Pressure; Pressure Indicator; Connection to the mains network
ProSpray 3.34 9 GB Starting operation 4 4.2 Control Panel Indicators The following is a description of the control panel indicators. Pressure Indicator Service Indicator Pressure Indicator The pressure indicator shows the current operating pressure of the sprayer. It has three different indications:...
Page 10 - Display; Function Keys
10 ProSpray 3.34 GB Starting operation 4.5 Cleaning preserving agent when starting- up of operation initially 1. Immerse the suction tube (Fig. 7, Item 1) and return hose (2) into a container with a suitable cleaning agent. 2. Turn the pressure control knob counterclockwise (3) to minimum pressure. ...
Page 11 - setting a security code for the first time, the
ProSpray 3.34 11 GB Starting operation Volume Pumped Screen VOLUME PUMPED SELECT-4 MENU-1 The Volume Pumped screen shows the total number of gallons or liters sprayed by the sprayer. GALLONS X MENU-1 LITRES X MENU-1 LITRES-2 GALLONS-2 To select the Volume Pumped screen, press the #4 key. job Volume ...
Page 13 - Cleaning unit from outside; Cleaning the high-pressure filter
ProSpray 3.34 13 GB Cleaning the unit (shutting down) 8. Cleaning the unit (shutting down) A clean state is the best method of ensuring operation without problems. After you have finished spraying, clean the unit. Under no circumstances may any remaining coating material dry and harden in the unit. ...
Page 14 - Type of malfunction; Possible cause; Measures for eliminating the malfunction; Remedy in case of faults; Cleaning Airless spray gun; Intake filter in Airless spray gun
14 ProSpray 3.34 GB Cleaning the unit (shutting down) Remedy in case of faults Type of malfunction A. Unit does not start B. Unit does not draw in material C. Unit draws in material, but the pressure does not build up Possible cause 1. No voltage applied. 2. Pressure setting too low. 3. ON/OFF switc...
Page 15 - Error Messages
ProSpray 3.34 15 GB Remedy in case of faults Type of malfunction D. Coating material exits at the top of the fluid section E. Increased pulsation at the spray gun F. Poor spray pattern G. Unit loses power Possible cause 1. Upper packing is worn. 2. Piston is worn. 1. Incorrect high-pressure hose typ...
Page 16 - General servicing; Repairs at the unit; Before all repair work: unplug the power plug; Inlet and outlet valve; Danger of crushing - do not reach with the
16 ProSpray 3.34 GB Servicing Repairs at the unit 10. Servicing 10.1 General servicing Servicing of the unit should be carried out once annually by the WAGNER service. 1. Check high-pressure hoses, device connecting line and plug for damage. 2. Check the inlet valve, outlet valve and filter for wear...
Page 17 - Do not tighten vice excessively to prevent; Do not damage inside of upper housing.
ProSpray 3.34 17 GB Repairs at the unit 14. Unscrew lower housing (Fig. 13, Item 10) with adjusting wrench while holding the upper housing (11) securely with a second adjusting wrench. 15. Remove bearing ring (13) and O-ring (12). 16. Screw out outlet valve housing (14) from the piston (15) with 3/8...
Page 20 - Appendix; Airless tip table; Spray gun filter “RED”
20 ProSpray 3.34 GB Appendix Application Tip Spray Bore Spraying marking angle inch / mm width mm 1) Order no. Natural paints 407 40° 0.007 / 0.18 160 0552 407 Clear paints 507 50° 0.007 / 0.18 190 ––––––– Oils 209 20° 0.009 / 0.23 145 0552 209 309 30° 0.009 / 0.23 160 0552 309 409 40° 0.009 / 0.23 ...
Page 21 - Description
ProSpray 3.34 21 GB Appendix 12.5 TempSpray The paint material is heated to the required temperature uniformly by an electric heating element, which is located inside the hose (regulated from 20°C to 60°C). Advantages: • Constant paint temperature even at low outside temperatures • Considerably bett...
Page 22 - Suitable for the following models:; Nespray Deco; Example of use
22 ProSpray 3.34 GB Appendix 12.6 Pump-Runner (Order No. 2306987) Universal accessories for cleaning, clean transportation and preservation of the pump unit. Features: • Simpler cleaning – the cleaning liquid circulates constantly through the pump making thorough cleaning of the interior • No cleani...
Page 24 - Accessories illustration
24 ProSpray 3.34 Accessories illustration ProSpray 3.34 3 1 5 7 2 4 6 8
Page 30 - Item
30 ProSpray 3.34 Spare parts list ProSpray 3.34 1516 17 18 4 5 6 7 8 9 11 121314 10 1 23 Drive Assembly Item Part No. Description 1 0290 241 Slider assembly 2 0507 767 Screw (4) 3 0290 272 Slider housing 4 0558 342A Housing assembly 5 0558 362A 3rd stage gear 6 0558 363A 2nd stage gear 7 0508 559 Sc...
Page 31 - Spare parts list
ProSpray 3.34 31 ProSpray 3.34Filter assembly Spare parts list 1 2 3 4 5 678 9 10 11 12 13 14 Item Part No. Description 1 0508 723 Filter housing 2 14058 Conical spring 3 0507 748 Filter, 60 mesh (standard) 0508 451 Filter, 30 mesh 0508 452 Filter, 100 mesh 6 0551 951 O-ring 7 0507 739 Pipe plug 8 0...
Page 33 - Bushing
ProSpray 3.34 33 Item Part No. Description 1 0290 207 Handle assembly (includes items 7-8) 2 9805 352 Screw (2) 3 0290 257 Bushing 4 0290 235 Cart weldment 5 9894 275 Spring 6 0290 285 Carriage assembly 7 0509 386 Washer (4) 8 0295 608 Screw (4) 9 0290 236 Cam assembly 10 9805 353 Screw (2) 11 0294 ...
Page 36 - Declaration of conformity; Deutschland
36 ProSpray 3.34 Declaration of conformity Herewith we declare that the supplied version of WAGNER ProSpray 3.34 Complies with the following provisons applying to it: 2004/108, 92/31 EWG, 93/68 EWG, 2006/42. Applied harmonized standards, in particular: EN 292-1/-2, EN 1953, EN 55014, EN 60335-1, EN ...