Page 2 - Attention: Danger of injury by injection!; Airless units develop extremely high spraying pressures.
2 ProSpray 3.29 • 3.31 GB Warning! Attention: Danger of injury by injection! Airless units develop extremely high spraying pressures. Be safety conscious! 1 2 3 Never put your fingers, hands or any other parts of the body into the spray jet! Never point the spray gun at yourself, other persons or an...
Page 3 - Contents
ProSpray 3.29 • 3.31 3 GB Contents Contents Page 1. Safety regulations for Airless spraying ...................................... 4 1.1 Explanation of symbols used .............................................................. 4 1.2 Electric Safety .....................................................
Page 4 - Safety regulations for Airless spraying; Explanation of symbols used; HAZARD: InjEctIon InjuRy
4 ProSpray 3.29 • 3.31 GB Safety Regulations 1. Safety regulations for Airless spraying 1.1 Explanation of symbols used This manual contains information that must be read and understood before using the equipment. When you come to an area that has one of the following symbols, pay particular attenti...
Page 6 - General view of application; Application; Description of unit; Airless process; Materials
6 ProSpray 3.29 • 3.31 GB General view of application Description of unit 2. General view of application 2.1 Application 2.2 Coating materials Processible coating materials i Pay attention to the Airless quality of the coating materials to be processed. Dilutable lacquers and paints or those contain...
Page 8 - Technical data; Transportation in vehicle; Starting operation; High-pressure hose, spray gun and separating; Easyglide prevents increased wear and tear to the
8 ProSpray 3.29 • 3.31 GB Description of unit Starting operation 3.5 Technical data ProSpray 3.29 ProSpray 3.31 Voltage: 110-120 Volt, 50/60 Hz Max. current consumption: 13 A 15 A Power cord: 3 x 1.5 mm 2 – 6 m or 4.6m Acceptance capacity: 1725 Watt 1840 Watt Max. operating pressure: 221 bar (22.1 M...
Page 9 - Control Panel Indicators; Pressure Indicator; Connection to the mains network
ProSpray 3.29 • 3.31 9 GB Starting operation 4 4.2 Control Panel Indicators The following is a description of the control panel indicators. Pressure Indicator Service Indicator Pressure Indicator The pressure indicator shows the current operating pressure of the sprayer. It has three different indic...
Page 13 - cleaning unit from outside; Cleaning the high-pressure filter
ProSpray 3.29 • 3.31 13 GB Cleaning the unit (shutting down) 8. Cleaning the unit (shutting down) A clean state is the best method of ensuring operation without problems. After you have finished spraying, clean the unit. Under no circumstances may any remaining coating material dry and harden in the...
Page 14 - Type of malfunction; Remedy in case of faults; Cleaning Airless spray gun
Assembly 1. Place intake filter (3) with the long cone into the gun housing. 2. Screw in grip (2) into the gun housing and tight en. 3. Slot in protective guard (1). W arning: keep clear of ti p 250 barmax.3600 ps i 3 2 1 14 ProSpray 3.29 • 3.31 GB Cleaning the unit (shutting down) Remedy in case of...
Page 16 - general servicing; The risk of damage rises with the age of the high-; Repairs at the unit; Inlet and outlet valve; Danger of crushing - do not reach with the fingers or
16 ProSpray 3.29 • 3.31 GB Servicing Repairs at the unit 10. Servicing 10.1 general servicing Servicing of the unit should be carried out once annually by the WAGNER service. 1. Check high-pressure hoses, device connecting line and plug for damage. 2. Check the inlet valve, outlet valve and filter f...
Page 17 - Do not tighten vice excessively to prevent crushing.; Do not damage inside of upper housing.
ProSpray 3.29 • 3.31 17 GB Repairs at the unit 14. Unscrew lower housing (Fig. 13, Item 10) with adjusting wrench while holding the upper housing (11) securely with a second adjusting wrench. 15. Remove bearing ring (13) and O-ring (12). 16. Screw out outlet valve housing (14) from the piston (15) w...
Page 19 - Selection of tip; Servicing and cleaning of Airless hard-metal tips; Tip extension
ProSpray 3.29 • 3.31 19 GB Appendix 11. Appendix 11.1 Selection of tip To achieve faultless and rational working, the selection of the tip is of the greatest importance. In many cases the correct tip can only be determined by means of a spraying test.Some rules for this:The spray jet must be even.If...
Page 20 - Airless tip table; Wagner; All of the tips in the table below are supplied
20 ProSpray 3.29 • 3.31 GB Appendix 12.4 Airless tip table Wagner TradeTip 3 tip up to 270 bar (27 MPa) without tip F thread (11/16 - 16 UN) for Wagner spray guns Order no. 0289391 without tip G thread (7/8 - 14 UN) for Graco/Titan spray guns Order no. 0289390 i All of the tips in the table below ar...
Page 22 - Suitable for the following models:
22 ProSpray 3.29 • 3.31 GB Appendix 12.5 Pump-Runner (Order No. 2306987)Universal accessories for cleaning, clean transportation and preservation of the pump unit. Features: • Simpler cleaning – the cleaning liquid circulates constantly through the pump making thorough cleaning of the interior • No ...
Page 24 - Accessories illustration
24 ProSpray 3.29 • 3.31 Accessories illustration ProSpray 3.29 / 3.31 3 1 5 7 2 4 6 8
Page 32 - Item
32 ProSpray 3.29 • 3.31 ProSpray 3.29 / 3.31 1 2 3 4 5 6 789 101112 13 14 Filter assembly Spare parts list Item Part No. Description 1 0524 918 Filter housing 2 14058 Conical spring 3 0508 748 Filter, 60 mesh (standard) 0508 451 Filter, 30 mesh 0508 452 Filter, 100 mesh 4 0508 603 Bearing ring 5 050...