Page 2 - Attention: Danger of injury by injection!; Airless units develop extremely high spraying pressures.
2 ProSpray 3.25 GB Warning! Attention: Danger of injury by injection! Airless units develop extremely high spraying pressures. Be safety conscious! 1 2 3 Never put your fingers, hands or any other parts of the body into the spray jet! Never point the spray gun at yourself, other persons or animals.N...
Page 3 - Contents
ProSpray 3.25 3 GB Contents Contents Page 1. Safety regulations for Airless spraying ...................................... 4 1.1 Explanation of symbols used .............................................................. 4 1.2 Electric Safety ............................................................
Page 4 - Safety regulations for Airless spraying; Explanation of symbols used; HAZARD: INjECTION INjuRy
4 ProSpray 3.25 GB Safety Regulations 1. Safety regulations for Airless spraying 1.1 Explanation of symbols used This manual contains information that must be read and understood before using the equipment. When you come to an area that has one of the following symbols, pay particular attention and ...
Page 6 - General view of application; Coating materials; Description of unit; Airless process; Materials
6 ProSpray 3.25 GB General view of application Description of unit 2. General view of application 2.1 Application 2.2 Coating materials Processible coating materials i Pay attention to the Airless quality of the coating materials to be processed. Dilutable lacquers and paints or those containing sol...
Page 8 - Technical data; Acceptance capacity:; Transportation in vehicle; Starting operation; High-pressure hose, spray gun and separating; EasyGlide prevents increased wear and tear to the
8 ProSpray 3.25 GB Description of unit Starting operation 3.5 Technical data Voltage: 100-110 Volt , 50/60 Hz Max. current consumption: 11 A Power cord: 3 x 1.5 mm 2 – 6m, 4.6 m or 2.5 m Acceptance capacity: 1100 Watt Max. operating pressure: 221 bar (22.1 MPa) Volume flow at 12 MPa (120 bar) with w...
Page 9 - Control Panel Indicators; Pressure Indicator; Connection to the mains network
ProSpray 3.25 9 GB Starting operation 4 4.2 Control Panel Indicators The following is a description of the control panel indicators. Pressure Indicator Service Indicator Pressure Indicator The pressure indicator shows the current operating pressure of the sprayer. It has three different indications:...
Page 13 - Cleaning unit from outside; Suction filter
ProSpray 3.25 13 GB Cleaning the unit (shutting down) 8. Cleaning the unit (shutting down) A clean state is the best method of ensuring operation without problems. After you have finished spraying, clean the unit. Under no circumstances may any remaining coating material dry and harden in the unit.T...
Page 14 - Type of malfunction; Remedy in case of faults; Cleaning Airless spray gun
14 ProSpray 3.25 GB Cleaning the unit (shutting down) Remedy in case of faults Type of malfunction A. Unit does not start B. Unit does not draw in material C. Unit draws in material, but the pressure does not build up Possible cause 1. No voltage applied. 2. Pressure setting too low. 3. ON/OFF switc...
Page 16 - General servicing; The risk of damage rises with the age of the high-; Repairs at the unit; Inlet and outlet valve; Danger of crushing - do not reach with the fingers or
16 ProSpray 3.25 GB Servicing Repairs at the unit 10. Servicing 10.1 General servicing Servicing of the unit should be carried out once annually by the WAGNER service. 1. Check high-pressure hoses, device connecting line and plug for damage. 2. Check the inlet valve, outlet valve and filter for wear...
Page 19 - Selection of tip; Servicing and cleaning of Airless hard-metal tips; Tip extension
ProSpray 3.25 19 GB Appendix 12. Appendix 12.1 Selection of tip To achieve faultless and rational working, the selection of the tip is of the greatest importance. In many cases the correct tip can only be determined by means of a spraying test.Some rules for this:The spray jet must be even.If streak...
Page 20 - Airless tip table; Wagner; All of the tips in the table below are supplied
20 ProSpray 3.25 GB Appendix 12.4 Airless tip table Wagner TradeTip 3 tip up to 270 bar (27 MPa) without tip F thread (11/16 - 16 UN) for Wagner spray guns Order no. 0289391 without tip G thread (7/8 - 14 UN) for Graco/Titan spray guns Order no. 0289390 i All of the tips in the table below are suppl...
Page 22 - Suitable for the following models:
22 ProSpray 3.25 GB Appendix 12.5 Pump-Runner (Order No. 2306987)Universal accessories for cleaning, clean transportation and preservation of the pump unit. Features: • Simpler cleaning – the cleaning liquid circulates constantly through the pump making thorough cleaning of the interior • No cleanin...
Page 24 - Accessories illustration
24 ProSpray 3.25 Accessories illustration ProSpray 3.25 3 1 5 7 2 4 6 8
Page 28 - Item
28 ProSpray 3.25 Spare parts list ProSpray 3.25 24 23 2526272829 30 31 32 33 34 1 8 9 10 11 121314 15 16 17 1819 20 21 22 2 3 4 5 7 6 Fluid section Item Part No. Description 1 0509 594 Retainer 2 0509 584 Piston guide 3 ------- Upper packing 4 0551 756 Transducer assembly 5 0507 517 Pipe plug 6 0290...