2 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert Table of Contents PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING THIS APPLICANCE. Thank you and congratulations on your purchase of a Majestic fireplace. IMPORTANT - Read all instructions and warnings car...
Page 3 - Insert Applications; Installation & Operating Instructions; PLEASE READ THE FOLLOWING CAREFULLY; Locating Your Gas Fireplace Insert
3 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert This gas appliance should be installed by a qualified installerin accordance with local building codes and with current CSA-B149.1 Installation codes for Gas Burning Appliances andEquipment. FOR U.S. Installations follow local c...
Page 4 - Minimum Fireplace; Fireplace & Trim Dimensions
4 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert R - Fireplace opening widthQ - Fireplace opening heightS - Depth of insertT - Firebox width at insert depth(S)U - Firebox depth at insert back height (V)V - Insert back height Minimum Fireplace Insert Opening RHEDV25 RHEDV32 RHE...
Page 5 - Natural; Minimum Inlet Pressure; Certified To; Input; The gas line connection can be made of
5 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert When the unit is installed into a woodburning fireplace,the minimum distance the mantel can be placed abovethe fireplace is governed by local building codes appli-cable to woodburning fireplaces. Consult local authori-ties havin...
Page 6 - Wait until the unit has warmed up sufficiently to; Fan Kit; Once fan starts, adjust speed control to desired fan; Fan Removal Instructions; Remove burner assembly and rear log support plate.
6 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert Always check for gas leaks with a mildsoap and water solution. Do not use anopen flame for leak testing. it HI LO OFF PILOT ThermostatBulb BrassPlug Gas Inlet Manifold GasOutlet Brass Plug PressureRegulator ControlKnob Thermocou...
Page 7 - Installation of Trim Switch; Left Side Installation; Back of Unit
7 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert Installation of Trim Switch for RN/RP Gas Valves 1. Thread wire through openings on the right side of fireplace. Do not cut wire or insulation on metal edges. 2. Slide switch assembly from the back, between subframe and trim, th...
Page 8 - WARNING; Air Intake
8 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert 4. The chimney must be clean and in good working order and constructed of noncombustible materials. 5. Make sure that all chimney cleanouts fit properly so air cannot leak into the chimney. 6. Install the appliance without trim ...
Page 9 - NOTE: Insulation can be installed above the damper; Ceramic Refractory Installation
9 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert Under no circumstances shouldinsulation be put between the damperand the top of the unit. This may causecondensation and overheating of the unit. Flue CollarPlate 10/24" x 1 ¹⁄₂ " Machine Screw CabinetTop FastenerPlate F...
Page 10 - Venting Components; Flex Vent Kit; Flex Vent Kit
10 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert Venting Components A B C High Temperature Sealant D 8" x 12" Vent Termination Kit Model: HEDVT (8" x 12") (Fit typical 8" x 12" and 9" x 13" flue tile) Kit Includes: A - 8" x 12" Vent Ter...
Page 11 - Operating Instructions; General Glass Information; The use of substitute glass will void all product; Louvre Removal; Glass Cleaning; Lift up and unhook glass frame at the top.; Log Installation and Burner Lava Rock; Place burner lava rock material on top of burner.; Fig. 17 Remove four screws to remove glass frame.
11 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert Operating Instructions General Glass Information Only ceramic glass approved by VermontCastings, Majestic Products may be usedfor replacement on this unit. 1. The use of substitute glass will void all product warranties. 2. Car...
Page 12 - Large Lava Rock Placement; Flame Characteristics
12 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert SR2 SR5 SR6 SR4 SR3 SR1 Front Lava Rock Placement LG281 Fig. 20 RHEDV42 log and lava rock placement. Large Lava Rock Placement The large lava rock provided with this fireplace must beplaced on the firebox base on either side of...
Page 13 - SIT Pilot; First Firing
13 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert 3/8" - 1/2" SIT Pilot PSE Pilot F584-703 Fig. 24 Correct pilot flame appearance. RHEDV25/32 Fig. 25 Correct burner flame appearance for RHEDV25 andRHEDV32 models. LG283 RHEDV42 LG283 Fig. 26 Correct burner flame appeara...
Page 14 - FOR YOUR SAFETY READ BEFORE LIGHTING; WHAT TO DO IF YOU SMELL GAS; To Turn Off Gas To Heater; Lighting And Operating Instructions; Lighting Instructions; Euro SIT
14 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert 3. Open control access panel.4. Push in gas control knob slightly and turn clockwise to "OFF". Do not force. 5. Close control access panel. 1. STOP! Read the safety information above.2. Turn off all electrical power to ...
Page 15 - SYMPTOM; Troubleshooting the Gas Control System; SIT NOVA 820 Millivolt Valve
15 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert WARNING: Before doing any gas control service work, remove glass front. SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION 1. Spark ignitor will not light A. Defective or misaligned Using a match, light pilot. If pilot lights, turn off ...
Page 16 - Eurosit 630 Gas Valve
16 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert Eurosit 630 Gas Valve NOTE: Before troubleshooting the gas control system, be sure external gas shut off is in the "On" position. WARNING: Before doing any gas control service work, remove glass front. Symptom Possible ...
Page 17 - START; Honeywell Millivolt Valve
17 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert Gas Supply On Supply Line Hooked UpShutoff Valve Open NO NO NO NO Lockout Has Engaged. Wait 60 Seconds And Try Again.For Spark At Electrode While Depressing Piezo 1/8" Gap To Pilot Hood Needed.All Wiring ConnectionsReplace ...
Page 18 - Maintenance; Burner and Burner Compartment; Cleaning the Standing Pilot
18 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert Maintenance Burner and Burner Compartment It is important to keep the burner and the burnercompartment clean. At least once per year the logs andlava rock/ember material should be removed and theburner compartment vacuumed and ...
Page 20 - Description
20 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert RHEDV25/32/42 Series (continued) Ref. Description RHEDV25 RHEDV32 RHEDV42 1. Log Set Complete 10000199 57896 10000206 1a. Log Ember Front JR1 KR1 SR1 1b. Log Front Left JR2 KR2 SR2 1c. Log Front Right JR3 KR3 SR3 1d. Log Rear J...
Page 22 - Optional Accessories; Remote Controls; Model; A Trim Options for RHEDV25; For use with RHEDV25; Trim Assembly; Side View; Zero Clearance Kit
22 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert Optional Accessories Remote Controls Optional remote control units are available to controldifferent functions of the appliance. Model Function(s) Controlled MRC1 ON/OFF MRC2 ON/OFF and Temperature MRC3 ON/OFF and Temperature c...
Page 23 - ALL repair parts will be available from your local dealer.; Key; Install top and bottom brass trim by using the short-; Fig. 27 Install top and bottom brass trim.; RHE25SSP & HE25LP Replacement Parts; Fig. 29 Slide bottom decorative plate under unit floor.
23 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert 4 2 3 4 1 6 6 5 FP1289 Vermont Castings, Majestic Products reserves the right to makechanges in design, materials, specifications, prices and discontinuecolors and products at any time, without notice. IMPORTANT: Only trim pane...
Page 24 - HE25FP Replacement Parts
24 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert 1 2 3 4 5 FP1293 Vermont Castings, Majestic Products reserves the right to makechanges in design, materials, specifications, prices and discontinuecolors and products at any time, without notice. IMPORTANT: Only trim panel asse...
Page 25 - Fig. 36 Attach magnets and brass trim to the steel frame.; HE25BTKP Replacement Parts
25 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert KT210a Fig. 34 Hang the window grille or the steel frame onto thelower tabs of the hanging brackets. KT211a Fig. 35 Engage the slots in the upper grille top louvre with theupper tabs of the hanging brackets. KT212a Fig. 36 Atta...
Page 26 - A4 Riser Kits; Riser Trim Dimensions; B Trim Options for RHEDV32; For use with RHEDV32; Frame Assembly; Rear View; Fig. 38 Attach left and right frame to frame top.; Fig. 39 Install trim channels and trim top deflector.
26 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert A4 Riser Kits For use with RHEDV25 (Refer to Page 34, Figure 55) 1. Install the unit according to Homeowner’s Manual. 2. Install the trim according to Installation Instructions. 3. Remove the two (2) screws at the bottom of the...
Page 27 - Fig. 41 RHESSD and RHESLD trim assembly.; Frame Mounting; Front View
27 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert Trim TopChannel TrimSideChannel TrimFramingInner Sides Screw TrimSideChannel DeflectorTrim Top FP1262 Fig. 41 RHESSD and RHESLD trim assembly. A flat louvre kit OR a bay window kit needto be chosen to complete the installation....
Page 29 - B2 RHEBSL & RHEBXL Trims; RHEBSL; RHEBXL
29 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert B2 RHEBSL & RHEBXL Trims For use with RHEDV32 Trim Assembly RHEBSL 1. Install trim channels (left and right sides). Use two screws to assemble each piece. 2. Slide on the trim top channel and fasten it from the back side. 3...
Page 30 - B3 RHEFA and RHEFP Trims; Install support window trim channel, top and bottom; RHEFA & RHEFP TrimReplacement Parts
30 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert B3 RHEFA and RHEFP Trims For use with RHEDV32 Trim Assembly 1. Remove the front glass (see "Glass Frame Re- moval" section). 2. Install support window trim channel, top and bottom brass trim by using the shortest black ...
Page 31 - Fig. 46 Optional bay front windows available for use on the RHEDV32.; HECBTKP, HECBTKMB and HESBTKP; HEBTKP
31 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert B4 HEBTKP, HESBTKP, HECBTK, HECBTKMB & HEBTA Trims For use with RHEDV32 HECBTK Cast bay window and grilles in classic black trim kit HECBKMB Cast bay window and grilles in midnight black porcelain enamel trim kit HESBTKP St...
Page 32 - Fig. 53 Attach magnets and brass trim to the steel frame.
32 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert On units fitted with a Honeywell brand controlvalve the location of the control knobs andthe ignitor button may vary slightly from thoseshown in Figure 49. The Honeywell exten-sion pieces are visually different in designand are...
Page 34 - Cast Surround and Flat Face; Length A; For use with RHEDV42
34 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert B5 Cast Trim Options Cast Surround and Flat Face HECBL Cast Surround Black HECBLUE Cast Surround Blue HECCG Cast Surround Charcoal Grey HECGR Cast Surround Green CSSP Polished Brass Small Trim forCast Surround CSLP Polished Bra...
Page 35 - Fig. 57 Install top and bottom brass trim.; RHE42SSP & RHE42LP Replacement Parts
35 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert 1. Install trim channels (left and right sides) by remov- ing the two screws that hold the side brass trim andput them back to hold both parts. 2. Slide on the trim top channel and fasten it from the back side. 3. Remove the tw...
Page 36 - Fig. 59 Slide bottom decorative plate under unit floor.; RHE42FP Replacement Parts
36 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert BottomDecorativePlate FP1292 Fig. 59 Slide bottom decorative plate under unit floor. IMPORTANT: Only trim panel assemblies approvedby Vermont Castings, Majestic Products can beused on these products. ALL repair parts will be av...
Page 37 - Fig. 66 Attach magnets and brass trim to the steel frame.; HE42BTKP Trim Replacement Parts
37 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert ExtensionKnobs KT204a Fig. 62 Install the knob extensions. (Only for RN/RP models) Fig. 64 Hang the window grille or the steel frame onto thelower tabs of the hanging brackets. KT212a Fig. 66 Attach magnets and brass trim to th...
Page 38 - IF WARRANTY SERVICE IS NEEDED...; ) DO NOT ATTEMPT TO DO ANY SERVICE WORK; LIMITED LIFETIME WARRANTY
BASIC WARRANTY The Vermont Castings , Majestic Products Company (hereinafter referred to collectively as the Company) warrants that your newVermont Castings or Majestic Gas Fireplace/Stove is free from manufacturing and material defects for a period of one year from thedate of purchase, subject to t...