Page 2 - Vermont Castings Jefferson Vent Free Gas Heater; Assembly Procedures; Table Of Contents
2 2 Vermont Castings Jefferson Vent Free Gas Heater 20003447 Installation and Operating Instructions ....................................................................................... 3 JUVS Dimensions ................................................................................................
Page 3 - Installation & Operating Instructions; F temperature rating.
3 Vermont Castings Jefferson Vent Free Gas Heater 20003447 Installation & Operating Instructions In order to ensure safe and effective installation, this unitmust be installed only by a qualified agency, individual, firm,corporation or company that is experienced in the installa-tion, repair and...
Page 4 - JUVS Dimensions
4 4 Vermont Castings Jefferson Vent Free Gas Heater 20003447 JUVS Dimensions 28 ¹⁄₂ " (724mm) 24" (610mm) 3" (76mm) 14 ¹⁄₂ " (368mm) C L 8" (203mm) Valve Inlet 3447 Fig. 1 Jefferson Vent Free dimensions.
Page 5 - Clearance Requirements; Minimum Clearances to; Mantel; Hearth Requirements
5 Vermont Castings Jefferson Vent Free Gas Heater 20003447 Clearance Requirements Minimum Clearances to Combustible Materials Maintain clearance, (empty space), between combus-tible materials and the heater as specified below forthe appropriate firebox shell being installed. Wall FP599a S T U V W X ...
Page 6 - Unvented Heaters; Input
6 6 Vermont Castings Jefferson Vent Free Gas Heater 20003447 Firebox weight / shipping 110 lbs. The installation of your Vermont Castings stove mustconform with local codes, or in the absence of localcodes, with the National Fuel Gas Code ANSIZ223.1 - latest edition. (EXCEPTION: Do not deratethis ap...
Page 8 - W A R N I N G
8 8 Vermont Castings Jefferson Vent Free Gas Heater 20003447 2. Divide the volume of space by 50 cubic feet. Theresult is the maximum BTU/hour the space can support. Example: 3840 cubic feet divided by 50 = 76.8 or76,800 BTU/hour. 3. Add the BTU/hour ratings of all fuel-burning appli-ances installed...
Page 9 - Unpack the Stove; Lift the stove front up and then swing the bottom out; WARNING; CAUTION
9 Vermont Castings Jefferson Vent Free Gas Heater 20003447 Unpack the Stove Remove the stove assembly from the shipping cartonand inspect it for loose or damaged parts. Do not installthis appliance if any parts are loose or if there is anyvisual or suspected damage resulting from shipping orhandling...
Page 10 - Install ON/OFF Switch; Run wires down back of stove, under bottom of rear
10 10 Vermont Castings Jefferson Vent Free Gas Heater 20003447 MOTOR SNAPSTAT ON/OFFRHEOSTAT WHT WHT BLK BLK BLK GRN BLK ST236 Fig. 11 Fan wiring diagram. ST347a Fig. 10 Attach rheostat to control panel. Valve may lookdifferent. Rheostat Retaining Nut Control Knob Pinch Grommetto Remove SnapstatBrac...
Page 11 - Thermostat Wire / Gauge; Install the Log Set; Remove the logs from their packaging, and inspect; Connect the Gas Supply Line
11 Vermont Castings Jefferson Vent Free Gas Heater 20003447 Decorative Grate ST223 Fig. 14 Install back, left and right logs. 1 2 3 Thermostat Wire / Gauge Maximum Run 18 40 feet 20 25 feet 22 16 feet Thermostat Connection (optional) (R Models only) 1. Install the wall thermostat in the desired loca...
Page 12 - Install the Stove Front
12 12 Vermont Castings Jefferson Vent Free Gas Heater 20003447 Install the Stove Front The Front Plate attaches to the stove by four steel tabsthat engage with corresponding cast ribs on the sidesand bottom of the stove body. Position the Front about3” down from stove top and lift the plate to engag...
Page 13 - Operation; Your First Fire
13 Vermont Castings Jefferson Vent Free Gas Heater 20003447 Operation Your First Fire Read these instructions carefully and familiarizeyourself with the burner controls of this heater. The JUVSR uses a Honeywell control valve that allowsthermostatic, on/off switch regulation and has a sepa-rate Piez...
Page 14 - FOR YOUR SAFETY READ BEFORE LIGHTING; To Turn Off Gas To Heater; Lighting And Operating Instructions; Lighting Instructions
14 14 Vermont Castings Jefferson Vent Free Gas Heater 20003447 3. Open control access panel.4. Push in gas control knob slightly and turn clockwise to "OFF". Do not force. 5. Close control access panel. 1. STOP! Read the safety information above.2. Turn off all electrical power to the firepl...
Page 15 - Troubleshooting
15 Vermont Castings Jefferson Vent Free Gas Heater 20003447 Troubleshooting Follow these procedures in the order presented. W A R N I N G TURN OFF HEATER AND ALLOW TO COOLCOMPLETELY BEFORE SERVICING. CONDITION POSSIBLE CAUSE SOLUTION No spark at pilot when Ignitor isoperated. 1. Ignition Electrode i...
Page 16 - CONDITION
16 16 Vermont Castings Jefferson Vent Free Gas Heater 20003447 Troubleshooting cont’d. CONDITION POSSIBLE CAUSE SOLUTION Pilot lights but flame goes outwhen Control Knob is released. 1. Control Knob not fully depressed or held in long enough. 2. Gas supply line shut-off valve is not fully open. 3. T...
Page 17 - Maintenance; Firebox Cleaning and Inspection; This appliance should be inspected and thor-; Cleaning Procedure
17 Vermont Castings Jefferson Vent Free Gas Heater 20003447 Maintenance WARNING Dust and debris accumulation can result in poorperformance. Inspect the valve compartment,burner parts and log set frequently and cleanthese parts monthly or as often as accumulationwarrants. Fig. 30 Remove screen. ST208...
Page 20 - Optional Accessories; Fan Kits; ON/OFF and Temperature
20 20 Vermont Castings Jefferson Vent Free Gas Heater 20003447 Optional Accessories Fan Kits FK28 Fan Assembly The FK28 fan kit helps distribute heated air from withinthe firebox out into the room. The fan is controlled by asnapstat that turns power on and off as the fireboxtemperature rises above a...
Page 21 - IF WARRANTY SERVICE IS NEEDED...; ) Contact your supplier. Make sure you have your; LIMITED LIFETIME WARRANTY
21 Vermont Castings Jefferson Vent Free Gas Heater 20003447 BASIC WARRANTY The Vermont Castings , Majestic Products Company (hereinafter referred to collectively as the Company) warrants that your newVermont Castings or Majestic Gas Fireplace/Stove is free from manufacturing and material defects for...
Page 22 - Vermont Castings, Majestic Products
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777 www.majesticproducts.com • www.vermontcastings.com Vermont Castings, Majestic Products © Vermont Castings, Majestic Products