Page 2 - Pyromaster; Venting Installation Instructions; Table of Contents
2 Pyromaster © H33BDVRRN/P 10004798 Installation & Operating Instructions ........................................................................................... 3 Locating Your Fireplace .................................................................................................... 3Fi...
Page 3 - PLEASE REVIEW THE FOLLOWING CAREFULLY; Installation & Operating Instructions; Locating Your Fireplace
3 Pyromaster © H33BDVRRN/P 10004798 A) Flat on wall B) Cross corner C) **Island D) *Room divider E) *Flat on wall corner F) Chase installation Y) 6" minimum Note (Fig. 1):** Island (C) and Room Divider (D) installation is possible as longas the horizontal portion of the vent system (X) does not ...
Page 4 - Fireplace Dimensions; Fig. 2 Fireplace specifications and framing dimensions.; Framing Dimensions
4 Pyromaster © H33BDVRRN/P 10004798 Fireplace Dimensions Fig. 2 Fireplace specifications and framing dimensions. F Q - Rough Opening Width RoughOpeningHeight RoughOpeningDepth M M O N P E I H J C A D R B K L G 4758 Ref. H33BDVRRN/P A 33” (838mm) B 28 ⁷⁄₈ ” (733mm) C 16 ³⁄₈ ” (416mm) D 31” (787mm) E ...
Page 5 - Rear Vent Applications:; Hearth; Fig. 3a Combustible mantel minimum installation.
5 Pyromaster © H33BDVRRN/P 10004798 Appliance Top.............................................. 0” (0 mm)Bottom........................................ 0” (0 mm)Side............................................ 0” (0 mm)Back........................................... 0” (0 mm) VentingConcentric secti...
Page 6 - Certified To; Vented Gas Fireplace Heaters
6 Pyromaster © H33BDVRRN/P 10004798 Noncombustible materials such as brick or tile may beextended over the edges of the face of the fireplace.DO NOT cover any vent or grille panels. If a Trim Kit is going to be installed on the fireplace, thebrick or tile will have to be installed flush with theedge...
Page 7 - Installation; Thread the wiring through the holes on the end; Alternate Switch Location
7 Pyromaster © H33BDVRRN/P 10004798 Installation 1. Thread the wiring through the holes on the end panels of the fireplace. Take care not to cut the wireor insulation on metal edges. Route the wire to aconveniently located receptacle box. 2. Attach the wire to the ON/OFF switch and install the switc...
Page 8 - General Venting Information - Termination Location; Canadian Installations
8 Pyromaster © H33BDVRRN/P 10004798 V V V V V V V X X X D E B B B C B M B A J K F L VENT TERMINATION AIR SUPPLY INLET AREA WHERE TERMINAL IS NOT PERMITTED H I Fixed Closed Fixed Closed Operable Operable Fixed Closed V B INSIDE CORNER DETAIL V A G V N N V V G G A CFM145a General Venting Information -...
Page 9 - Outside Corner; Termination Clearances; Recessed Location; Crimped End Pipes; Canadian Installations:; General Information on Assembling DV Components; Fig. 9 Apply a bead of high temperature sealant.
9 Pyromaster © H33BDVRRN/P 10004798 Outside Corner Inside Corner Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors. A =Combustible 6"(152mm) Noncombustible 2"(50mm) B =Combustible 6"(152mm) Noncombustible 2"(50mm) A Balcony - wi...
Page 10 - Twist Lock Pipes; How to Use the Vent Graph; Rear Wall Vent Applications
10 Pyromaster © H33BDVRRN/P 10004798 Twist Lock Pipes When using CFM Corporation twist-lock pipe it is notnecessary to use sealant on the joints. The only areasof the venting system that need to be sealed with hightemperature silicone sealant are the collars on thefireplace and termination, and the ...
Page 11 - Combustible Walls: Cut a 10; Rear Wall Installations
11 Pyromaster © H33BDVRRN/P 10004798 STEP 1 Locate vent opening on the wall. To locate hole centerconsult with appropriate fireplace dimensions, Page 4.Frame as shown below. Combustible Walls: Cut a 10 ³⁄₈ ”H (264 mm) x 9 ³⁄₈ ” W (240 mm) hole through the exterior wall and frame asshown. (Fig.13) No...
Page 12 - Fig. 16 Side view of final unit location.; Vertical Sidewall Applications; The maximum number of 90; Fig. 18 Maximum horizontal vent run before termination.
12 Pyromaster © H33BDVRRN/P 10004798 STEP 5 Guide the vent termination 4” collar into the 4” pipethen the 7” collar into the 7” pipe. Do not force theventing into position. If the pipes do not line up with thetermination collars, disassemble pipes and reattach tothe fireplace collar. (Fig. 16) STEP ...
Page 13 - Vertical Sidewall Installations; elbow is; Vent Opening for Combustible Wall; Total angular variation = 270
13 Pyromaster © H33BDVRRN/P 10004798 Vertical Sidewall Installations Example: According to the chart the maximumhorizontal vent length in a system with a 7.5'vertical rise is 20' (6 m) and if a 90 ° elbow is required in the horizontal vent it must be reduced to17' (5.2 m). In Figure 20 Dimension A p...
Page 14 - Fig. 22 Zero clearance sleeve and firestop.
14 Pyromaster © H33BDVRRN/P 10004798 STEP 2 Measure wall thickness and cut adjustable zero clear-ance sleeve parts to proper length (MAXIMUM 12”/305mm). (Fig. 22) Adjust sleeve to minimum (9 ³⁄₈ ” x 9 ³⁄₈ ”) and attach to firestop with #8 sheet metal screws(supplied). Assemble sleeve and attach to f...
Page 15 - Below Grade Installations
15 Pyromaster © H33BDVRRN/P 10004798 Below Grade Installations Do not back fill around snorkel. Aclearance of at least 4” (100mm) must bemaintained between the snorkel and thesoil. STEP 6 Apply high temperature sealant to 4” (100 mm) and 7”(175 mm) collars or the termination one inch away fromthe cr...
Page 17 - Typical Roof; Install appropriate pipe sections until the venting is; Fig. 34 Minimum termination to roof clearance.
17 Pyromaster © H33BDVRRN/P 10004798 If there is room above ceiling level,firestop spacer must be installed on boththe bottom and the top side of the ceilingjoists. If an attic is above ceiling level a7DVAIS (Attic Insulation Shield) must beinstalled. (Fig. 31) The enlarged ends of the vent sectiona...
Page 18 - Twist Lock Venting Components
18 Pyromaster © H33BDVRRN/P 10004798 Twist Lock Venting Components 7TDVRVT-Through the wall Rear Vent Termination Starter Kit-Model7TDVSK-Sidewall VentingStarter Kit-Model 7TDVSKV-Vertical Venting for 7TDVSKV-A order 1/12 to 6/12 roof pitchfor 7TDVSKV-B order 7/12 to 12/12 roof pitchfor 7TDVSKV-F or...
Page 19 - Crimped End Venting Components
19 Pyromaster © H33BDVRRN/P 10004798 Crimped End Venting Components 7TDVRVT-Through the wall Rear Vent Termination Starter Kit-Model 7TDVSK-Sidewall VentingStarter Kit-Model 7TDVSKV-Vertical Venting for 7TDVSKV-A order 1/12 to 6/12 roof pitchfor 7TDVSKV-B order 7/12 to 12/12 roof pitchfor 7TDVSKV-F ...
Page 20 - If the unit has been operating allow time for the; Operating Instructions
20 Pyromaster © H33BDVRRN/P 10004798 Only glass approved by the CFMCorporation should be used on thisfireplace. The top louvre panel isremoved by lifting thepanel vertically and pullingit away from the appliance.(Fig. 35) The lower accessdoor is hinged along thebottom edge and is foldeddown to allow...
Page 21 - Flame Characteristics; Location; Front Right; Refer to Figure 37; Scatter the ember material over the front area of the; Scatter the lava rock material around the firebox base.; LO
21 Pyromaster © H33BDVRRN/P 10004798 For units equipped with ‘HI/LO’ valves the flameadjustment is accomplished by rotating the ‘HI/LO’adjustment knob located near the center of the gascontrol valve. (Fig. 38) It is important to periodically perform a visual check ofthe pilot and burner flames. Comp...
Page 22 - FOR YOUR SAFETY READ BEFORE LIGHTING; WHAT TO DO IF YOU SMELL GAS; To Turn Off Gas To Heater; Lighting And Operating Instructions; Lighting Instructions; Euro SIT
22 Pyromaster © H33BDVRRN/P 10004798 3. Open control access panel.4. Push in gas control knob slightly and turn clockwise to "OFF". Do not force. 5. Close control access panel. 1. STOP! Read the safety information above.2. Turn off all electrical power to the fireplace.3. For MN/MP/TN/TP app...
Page 23 - Troubleshooting – Honeywell VS8421; Remove Glass Doors Before Service Work
23 Pyromaster © H33BDVRRN/P 10004798 Troubleshooting – Honeywell VS8421 START CHECK Remove Glass Doors Before Service Work GAS SUPPLY ON ▼ ▼ ▼ ▼ ▼ PILOT LIGHTS WITHPIEZO IGNITOR • Lockout Has Engaged. Wait 60Seconds And Try Again. • For Spark At Electrode WhileDepressing Piezo1/8" Gap To Pilot H...
Page 24 - LP Conversion Kit Components
24 Pyromaster © H33BDVRRN/P 10004798 This unit is factory setup for use with natural gas. The conversion of this appliance fromnatural gas to propane gas must becarried out by an authorized serviceprovider. LP Conversion Kit Components (Supplied with unit.) Description Part # Pilot Orifice #35 10002...
Page 25 - Maintenance; Burner and Burner Compartment
25 Pyromaster © H33BDVRRN/P 10004798 Maintenance Burner and Burner Compartment It is important to keep the burner and the burnercompartment clean. At least once per year the logs andlava rock/ember material should be removed and theburner compartment vacuumed and wiped out. Removeand replace the log...
Page 26 - Description; Burner Housing Assembly
26 Pyromaster © H33BDVRRN/P 10004798 LO HI PILOT ADJ PILOT ON OFF 2 3a/b 1 1a 1b 1c 4 5 6 7 8 9a/b 11 12 13 17 14 15 16 18 10 4758 CFM Harris Systems reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. H33BD...
Page 28 - FK24 Fan Assembly; Optional Accessories Available; Fan Kits
28 Pyromaster © H33BDVRRN/P 10004798 FK24 Fan Assembly This auxiliary fan system increases the efficiency of thecirculation of the heated air. The FK24 fan kit allows variable speed control of thecirculation fan and also incorporates a heat sensor inthe circuit. Specifications 115 Volts / 60Hz / 56 ...
Page 29 - Wiring Instructions; Ceramic Refractory Kits; Inside
29 Pyromaster © H33BDVRRN/P 10004798 The fireplace, when installed, must beelectrically connected and grounded inaccordance with local codes or, in theabsence of local codes, with the currentCSA C22.1 Canadian Electric Code. For USA installations follow the localcodes and the national electrical cod...
Page 30 - Decorative Bay Windows; Fig. 45 Ceramic refractory installation.
30 Pyromaster © H33BDVRRN/P 10004798 Do not remove the existing window frameassembly. Top Louvre Bay WindowFrame BottomBrassTrim BottomLouvreAssemblies Spacers CeramicRefractory Screws FP1195 Fig. 47 Bay window installation. CeramicRefractory Decorative Bay Windows 4. Lay the angular base panels in ...
Page 31 - Model; Remote Controls; Let the fireplace cool down if it has been operating.; Trim Kit
31 Pyromaster © H33BDVRRN/P 10004798 Optional remote control units are available to controldifferent functions of the appliances. Model Function(s) Controlled RM4 ON/OFF w/batteries Remote Controls Bay Window Screen A Bay Window Screen Kit is available for theH33BDVRRN/P. Do not remove existing wind...
Page 32 - LIMITED WARRANTY & EXTENDED LIFE TIME PROTECTION; For Pyromaster; CFM Harris Systems
BASIC WARRANTY:CFM Harris Systems (hereinafter referred to collectively as the "Company")warrants that your new Pyromaster Gas Appliance is free from manufacturingand material defects for a period of one year from date of installation, subjectto the following conditions and limitations. EXTE...