Page 2 - ChateauTM; Table of Contents
2 Chateau™ 20011956 Please read the installation & operating instructions before using this appliance.Thank you and congratulations on your purchase of a CFM Corporation fireplace.IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instruc...
Page 3 - Installation & Operating Instructions; Proposition 65 Warning:; PLEASE REVIEW THE FOLLOWING CAREFULLY; “OFF”; Certified To; Vented Gas Fireplace
3 Chateau™ 20011956 This gas fireplace must be installed by a qualified installer, preferably NFI or WETT (Canada) certified, in accordance with local building codes and with current CSA-B149.1 Installation codes for Gas Burning Appliances and Equipment. For USA Installations follow local codes and/or ...
Page 4 - Fireplace Dimensions - DVT38; Fireplace specifications and framing dimensions for DVT38.; Fireplace Dimensions - DVT44; Fireplace specifications and framing dimensions for the DVT44.; No combustible
4 Chateau™ 20011956 Rough Opening Width ����� " (1114 mm) Rough Opening Height Rough Opening Depth 37 ��� " (962 mm) ����� " (876 mm) 54" (1372 mm) 76 ��� " (1 94 0 m m) 8 ��� " Dia. (213 mm) 11" Dia. (279 mm) 49 ��� " (1257 mm) 33 ��� " (848 mm) 2 ��� " (60 m...
Page 5 - Mantels; Locating Your Fireplace; Locate gas fireplace.; mantal chart; Mantel Chart; Combustible mantel leg minimum installation.
5 Chateau™ 20011956 A) Flat on wall B) Cross corner C) **Island D) *Room divider E) *Flat on wall corner F) Chase installation Y) 6” minimum NOTE (Fig. 3): ** Island (C) and Room Divider (D) installation is possible as long as the horizontal portion of the vent system (X) does not exceed 20’ (6 m). ...
Page 6 - Cold climate installation recommendation:; Hearth; nailing flanges
6 Chateau™ 20011956 A hearth is not mandatory but is recommended for aesthetic purposes. We recommend a noncombustible hearth which projects out 12” (305 mm) or more from the front of the fireplace. The hearth cannot exceed 1 ¹⁄₂ ” (38mm) in height from bottom of fireplace for ease of door accessibili...
Page 7 - Gas Inlet and Manifold Pressures; Minimum Inlet Pressure; High Elevations; INSTA VENT FREE; Always; when using black iron pipe so the gas; Gas Specifications; Propane
7 Chateau™ 20011956 Gas Inlet and Manifold Pressures Natural LP (Propane) Minimum Inlet Pressure 5.5” w.c. 11.0” w.c. Maximum Inlet Pressure 14.0” w.c. 14.0” w.c. Manifold Pressure 3.5” w.c. 10.0” w.c. High Elevations Input ratings are shown in BTU per hour and are certified without deration for elev...
Page 8 - this procedure.; Electrical Junction Box; Disconnect gas supply fitting and remove 13 screws; Connect gas supply to valve.
8 Chateau™ 20011956 The fireplace, when installed, must be elec-trically connected and grounded in accord-ance with local codes or, in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code or the national electrical code ANSI/NFPA No. 70 in the USA.It is strongly suggested t...
Page 9 - Special Feature for Cold Climates; Connect 120V AC electrical supply.
9 Chateau™ 20011956 NOTE: If you need to test the inlet pressure and/or manifold pressure, there are two (2) test ports available along the right side front edge between the firebox side and outer casing. The upper test port is inlet pressure. The lower test port is manifold pressure. CAUTION: Turn o...
Page 10 - General Venting; Location of Vent Termination
10 Chateau™ 20011956 General Venting Your fireplace is approved to be vented either through the side wall, or vertical through the roof. • Only CFM Corporation venting components spe-cifically approved and labelled for this fireplace may be used. • Venting terminals shall not be recessed into a wall or...
Page 11 - General Venting Information - Termination Location; for vinyl soffits; Canadian Installations
11 Chateau™ 20011956 V V V V V V V X X X D E B B B C B M B A J K F L VENT TERMINATION AIR SUPPLY INLET AREA WHERE TERMINAL IS NOT PERMITTED H I ����� ������ ����� ������ �������� �������� ����� ������ V B CFM145a DV Termin Location 5/01/01 Rev. 12/05/01 sta INSIDE CORNER DETAIL V A G V N N V V G G A...
Page 12 - Termination clearances.; Quick Reference for Fresh Air Restrictor Plate / Flue Baffle; Application; Termination Clearances; of Caps
12 Chateau™ 20011956 Fig. 13 Termination clearances. Quick Reference for Fresh Air Restrictor Plate / Flue Baffle Application Item DVT38N DVT38P DVT44N DVT44P SK8DVSK Flue Restrictor Plate 3” None None 4 ¹⁄₂ ” Fresh Air Restrictor Plate None None None #1 Vertical Less than 12’ Flue Restrictor Plate N...
Page 13 - Horizontal Termination; Vertical Termination; Canadian Installations:; The joints of the inner pipe (flue pipe) must be
13 Chateau™ 20011956 Horizontal Termination The vent must rise vertically a minimum of 24” (610mm) off the top of the unit, before the first elbow. The hori-zontal run may extend up to 20’ (6 m) and include a ver-tical rise of up to 40’ (12 m). (Fig. 15) Horizontal termi-nation must also meet the cri...
Page 14 - Sidewall Applications; Horizontal vent termination window.; Use of the Restrictor Plates in; Apply high temperature sealant or UL approved; Support straps for horizontal runs.; Minimum vertical run / maximum horizontal run.
14 Chateau™ 20011956 Sidewall Applications ������������������������� ������ ��� � � � � � � � � � �� �� �� �� �� �� �� �� �� �� �� Vertical Run (in feet) (Measured from the appliance flue collar to the top of the vent pi pe.) Horizontal Run (in feet) �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �...
Page 15 - Maximum vent run with elbows.; Maximum number of elbow degrees.; Vent Opening; Locate vent opening on wall.; Adjustable zero clearance sleeve.; 13) hole through the exterior wall and frame as shown.; Noncombustible Walls:; Hole opening must be 11; Sidewall Installation
15 Chateau™ 20011956 • The maximum number of 45° elbows permitted per side wall installation is two (2). These elbows can be installed in either the vertical or horizontal run. (Fig. 18) • For each 45° elbow installed in the horizontal run, the length of the horizontal run MUST be reduced by 18” (45...
Page 16 - If using the; Vertical height requirement.; Horizontal length requirement.
16 Chateau™ 20011956 STEP 3 Slide the zero clearance sleeve through the wall and install the firestop on the inside surface of the wall. Secure with four (4) #8 sheet metal screws. STEP 4 Place fireplace into position. (Fig. 22) Measure the ver-tical height (X) required from the base of the flue collar...
Page 17 - Secure termination to wall.; Use of Restrictor Plate; Applications; Restrictor plate use with horizontal offset.; ” restrictor plate; Restrictor plate use in straight up installation.; Fresh Air Restrictor Plate; Setting; This Gas Fireplace has been approved for,
17 Chateau™ 20011956 FP1243a Fig. 25 Secure termination to wall. Use of Restrictor Plate for Vertical Venting Applications The primary purpose for the vent restrictor is to regain flame height under certain venting conditions as outlined below. NOTE: The joints of the inner pipe (flue pipe) must be ta...
Page 18 - Typical offset application.
18 Chateau™ 20011956 Max. 20' (6 m) Max. Height 40' (12 m) Min. Height 20' (6 m) FP1244a through the roof max/min dims 4/03 Pipe Straps Every 3’ (914mm) FP1244a Fig. 28 Support straps for horizontal runs. • Up to two (2) 30° or 45° elbows may be used within the horizontal run. For each 30° or 45° el...
Page 19 - Attic Installation; Installing firestop spacer.; Elbow Strap; Attach straps to a structural framing member.
19 Chateau™ 20011956 FP593 SR/C 11/20/97 Attic Installation Ceiling Installation Nails (4) Firestop Spacer Joist Joist Firestop Spacer Nails (4) FP593 Fig. 30 Installing firestop spacer. FP263 MBUF 5/9/96 Attic Insulation Shield Ceiling Base Flanges Nails (4 Re- quired) Attic Joist FP263 Fig. 31 Atti...
Page 20 - Chimney Components; Model Number
20 Chateau™ 20011956 Chimney Components Horizontal Starter Kit Contains 24”-40” telescopic pipe* for minimum vertical SK8DVSK rise from collar pipe, 90° elbow, horizontal through-wall starter pipe, zero clearance sleeve, metal adhesive tape, stove cement tube, sidewall termination and firestop. SK8 C...
Page 21 - Tilt the glass frame at the top away from the unit.; Operating Instructions; Glass Information; Restrictor Plate Installation; Remove Phillips screws, tilt frame forward and lift off
21 Chateau™ 20011956 Only glass approved by CFM Corporation should be used on this fireplace. 1. Turn the fireplace OFF (including the pilot).2. If the unit has been operating allow time for the components to cool. 3. Using a Phillips screwdriver, unfasten two (2) screws located at the top of the glas...
Page 22 - remove rear; Remove rear log bracket.; Ceramic Refractory Installation; Appliance; refractory panels; heat shield/insulation; Restrictor plate location.
22 Chateau™ 20011956 6. Replace the rear lower and upper refractory, side refractory, fettle, andiron, logs and glass. FP1556 remove rear log bracket 3/05 djt Rear Log Bracket Remove Screws (3) Fig. 36 Remove rear log bracket. FP1556 FP1558 fresh restrictorplate adjustment3/05 djt 1 2 3 4 Fresh Air ...
Page 23 - Log, Lava Rock and Ember Placement; The logs are fragile and should be handled; DVT38 log identification.
23 Chateau™ 20011956 3. Start with either the right side refractory or left side refractory. Hold the refractory at an angle. Slide and seat the bottom edge toward the bottom of the firebox. Tilt it carefully toward the side until the piece is in place. Slide the refractory forward until it comes in ...
Page 24 - flat surface facing down.; DVT44 log identification.
24 Chateau™ 20011956 �������������������� Log Burner Overlay Log Grate Burner LG401 Figure 42 1. Position the Log Grate Burner. Remove the two (2) screws that attach the fettle to the burner. Place the log grate burner between the notch on the front of the burner housing behind the burner tube. (Fig...
Page 25 - Position the Log Grate Right and; Position the right and left grate; Position the Log Rear Left; Position the log rear left by; Position the Log Front Middle; Position the log front middle
25 Chateau™ 20011956 LG405rear logs3/05 Log Rear Left Log Rear Right LG405 Figure 44 �������������������������������� Log Front Left Log Front Right Log Front Middle Left Log Front Middle Right (DVT44) LG404 Figure 45 7. Position the Log Grate Right and Left. Position the right and left grate logs s...
Page 26 - DVT44 only. Position the Log Rear Upper
26 Chateau™ 20011956 LG406Upper logs3/05 Log Rear Upper Middle (DVT44 Only) Log Front Upper Right Figure 47 LG406 12. Position the Log Front Middle Right. DVT38 only. Hold the log with the pointed end toward the back and the wide end toward the front. Set the rectangular indentation located on the b...
Page 27 - DVT38 logset complete.
27 Chateau™ 20011956 ������������������� Fig. 48 DVT38 logset complete. Small Lava Rock Ember Material Volcanic Rock LG484 ������������������� Fig. 49 DVT44 logset complete. Small Lava Rock Ember Material Volcanic Rock LG482
Page 28 - Flame Characteristics; SIT Top Convertible; Correct pilot flame appearance.
28 Chateau™ 20011956 ������������������������� It is important to periodically perform a visual check of the pilot and burner flames. Compare them to the illustrations below. (Figs. 50 & 51)If the flame patterns appear abnormal contact a qualified service provider for service and adjustment. Flame ...
Page 29 - Trim Installation; The right and left trim pieces have a 45° notch on the; Trim frame in place.
29 Chateau™ 20011956 Trim Installation CAUTION: Allow fireplace to cool if it has been in operation. Trim components: Top frame assembly, bottom trim assembly, right and left trim assemblies. NOTE: Place trim pieces with magnets facing window frame.1. Place bottom trim on the bottom of the window fra...
Page 30 - Lighting & Operating Instructions
30 Chateau™ 20011956 Lighting & Operating Instructions For Fireplaces equipped with American Flame Automatic Control System (IN or IP) A. This fireplace is equipped with an ignition device which automatically lights the pilot and main burner. The pilot and burner light automatically with the hand...
Page 31 - Troubleshooting; Verify the gas supply is turned on.; A proper ground is essential to spark; Pilot will not light/stay lit; American Flame Gas Control System
31 Chateau™ 20011956 Troubleshooting If erratic system behavior is observed that cannot be resolved by the methods outlined below, ensure that there is not a transmitter with batteries installed that may be interfering. If a transmitter is packed with batteries installed, its buttons may be depresse...
Page 32 - Troubleshooting American Flame Gas Control System; Main flame will not light
32 Chateau™ 20011956 Troubleshooting American Flame Gas Control System (continued) Main flame will not light • Verify the gas supply is turned on. • Ensure the pilot flame will ignite. If not, see pilot flame troubleshooting above. • Make sure the green and white leads from the module are securely conn...
Page 33 - Fuel Conversion Instructions; bly section on Page 21.; pilot hood; Use 3/8” socket to remove hex nuts holding left; Slide the burner housing assembly to the left and
33 Chateau™ 20011956 Fuel Conversion Instructions WARNING! This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all appli-cable codes and requirements of the authority having jurisdiction. If the information in these instructions ...
Page 34 - Converting the Gas Control Valve; AF pilot orifice; Remove pilot orifice.; Check Manifold Pressure; Remove black plastic cap and adjust rotary knob to
34 Chateau™ 20011956 10. Install the conversion orifice.11. Reinstall pilot hood. Be sure to align hood with index tab. Converting the Gas Control Valve The AF4000 electronic control valve is convertible from natural gas to propane gas by changing the minimum rate screw in the valve and by rotating a...
Page 35 - Pilot Flame Adjustment
35 Chateau™ 20011956 Pilot Flame Adjustment Typically, the top 3/8” or 1/2” of the pilot flame sensor should be engulfed in the pilot flame. (Page 28, Fig. 50)To adjust pilot burner:1. Locate pilot adjustment screw on the valve next to the black plastic cap. Refer to Page 30. 2. Adjust pilot screw to ...
Page 36 - Maintenance; Burner and Burner Compartment; Cleaning the Control System; If repair is necessary, it should
36 Chateau™ 20011956 Maintenance Burner and Burner Compartment It is important to keep the burner and the burner compartment clean. At least once per year the logs and lava rock/ember material should be removed and the burner compartment vacuumed and wiped out. Remove and refit the logs as per the in...
Page 38 - Colonial Red; a. Refractory Set Complete
38 Chateau™ 20011956 DVT38, DVT44 (continued) Ref. Description DVT38 DVT44 1. Log Set (Complete) 20011953 20011954 1a. Log Grate Right 20011977 (F39) 20011964 (F54) 1b. Log Front Left 20011965 (F32) 20011965 (F32) 1c. Log Front Middle Left 20011966 (F33) 20011966 (F33) 1d. Log Front Upper Right 2001...
Page 39 - Fuel Conversion Kits
39 Chateau™ 20011956 DVT38, DVT44 (continued) Ref. Description DVT38 DVT44 17. 24” Wire Harness 20012258 20012258 18. Pilot Assy 3way N/DV Top Convertible - IN 10002387 10002387 19. Remote Control 20011904 20011904 20. Battery Back-up Module 20012473 20012473 21. Power Module (DC System Only) 200119...
Page 40 - Accessories; Ceramic Refractory Kits
40 Chateau™ 20011956 Accessories Ceramic Refractory Kits Ceramic refractory panels are available in kit form for the DVT38 and DVT44. Appliance Kit Model Description DVT38 DVT38CRR Colonial Red DVT38 DVT38CRL Limestone DVT38 DVT38CRH Herringbone DVT44 DVT44CRR Colonial Red DVT44 DVT44CRL Limestone D...
Page 43 - IF WARRANTY SERVICE IS NEEDED...; ) Contact your supplier. Make sure you have your warranty,; LIMITED LIFETIME WARRANTY; PRODUCT COVERED BY THIS WARRANTY
43 Chateau™ 20011956 BASIC WARRANTY CFM Corporation (hereinafter referred to collectively as the Company) warrants that your new Vermont Castings or Majestic Gas Fireplace/Stove is free from manufacturing and material defects for a period of one year from the date of purchase, subject to the followi...
Page 44 - Efficiency Ratings; Model; CFM Corporation
Efficiency Ratings Model EnerGuide Ratings Fireplace Efficiency (%) DVT38IN 48.2 DVT38IP 48.2 DVT44IN 51 DVT44IP 51 410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 800-668-5323 • www.cfmcorp.com CFM Corporation