Page 2 - TABLE OF CONTENTS; Thank you and congratulations on your purchase.
- 2 - TABLE OF CONTENTS PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possibl...
Page 3 - INSTALLATION INSTRUCTIONS
- 3 - IMPORTANT:PLEASE REVIEW THE FOLLOWINGCAREFULLY Remove any plastic from trim parts before turningthe fireplace ON. It is normal for fireplaces fabricated of steel to giveoff some expansion and/or contraction noisesduring the start up or cool down cycle. Similarnoises are found with your furnace...
Page 4 - FIREPLACE DIMENSIONS
- 4 - A 36" 914mm B 34 1/4" 870mm C 21" 533mm D 33" 838mm E 24" 610mm F 16" 406mm G 19" 483mm H 23 7/8" 606mm I 27 1/2" 698mm J 6 3/4" 171mm K 10" 254mm L 13 1/2" 343mm M 41 5/8" 1057mm N 58 7/8" 1495mm O 29 7/8" 748mm ROD 16 1/2" 419mm...
Page 5 - MANTEL CHART; MANTELS; Choose fireplace location.; FRAMING AND FINISHING; ADJUSTABLE DRYWALL STRIP
- 5 - Ref. Mantel Ref. Mantel From Mantel Leg from Depth Top Louvre Fireplace Side V 10" (254 mm) A 12" (305 mm) 10" (254mm) W 8" (203 mm) B 10" (254 mm) 8" (203mm) X 6" (152 mm) C 8" (203 mm) 6" (152mm) Y 4" (101 mm) D 6" (152 mm) 4" (101mm) Z 2" ...
Page 6 - Vented Gas Fireplace Heaters; GAS INLET & MANIFOLD PRESSURES; Input Minimum
- 6 - Do not use this fireplace if any part of it hasbeen under water. Immediately call a qualifiedservice technician to inspect the fireplaceand replace any part of the control which hasbeen under water. Cold climate installation recommendation:When installing this unit against a non-i n s u l a t ...
Page 7 - REMOTE SWITCH INSTALLATION; ALTERNATE SWITCH LOCATION:; GAS LINE INSTALLATION
- 7 - PILO T TPTH TP TH SIT VALVE 1/2" GAS SUPPLY 1/2" X 3/8" REDUCER 3/8" NIPPLE 3/8" NIPPLE 3/8" NIPPLE 3/8" X 3/8" SHUT OFF VALVE 3/8" UNION When using copper or flex connector use only approvedfittings. Always provide a union when using black ironpipe so that ...
Page 8 - clearance to outside comer see next page; GENERAL VENTING INFORMATION
- 8 - V V V V V V V V V X X X D E B B B C B M B A J K A F L G G TERMINATION CAP AIR SUPPLY INLET GAS METER RESTRICTED AREA(TERMINATION PROHIBITED) H I Fixed Closed Fixed Closed Openable Openable Fixed Closed G G N N Your fireplace is approved to be vented either throughthe side wall, or vertical thr...
Page 9 - Termination Clearances; Recessed Location; BEAD LOCATION; GENERAL INFORMATION ON ASSEMBLING
- 9 - Fig. 11 Outside Corner Inside Corner Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors. A =Combustible 6"(152mm) Noncombustible 2"(50mm) B =Combustible 6"(152mm) Noncombustible 2"(50mm) A Balcony - with no side wall G = Co...
Page 10 - STEP 2; REAR WALL INSTALLATIONS; STEP 3; REAR VENTING APPLICATIONS; T o p; Vent Starter Kit Model 7DVRVT must be; Locate vent opening on wall.
- 10 - Combustible Walls. Cut a 10-3/8"H x 9-3/8"W (265mmx 240mm) hole through the exterior wall and frame asshown. Fig. 14. Non-Combustible Walls: Hole opening must be 7.5"(190mm) in diameter. To locate hole centre consult withappropriate fireplace specifications, page 4. #8SCREWS(2) AD...
Page 11 - VERTICAL SIDEWALL INSTALLATIONS; For some installations, it may be desirable to
- 11 - FINISHED WALL VENT TERMINATION(7DVRVT) Fig. 16 STEP 5 Guide the vent termination 4" collar into the 4" pipe then the7" collar into the 7" pipe. Do not force the venting intoposition. If the pipes do not line up with the terminationcollars, disassemble elbows or pipes and reatt...
Page 12 - VERTICAL SIDEWALL APPLICATIONS; elbow is installed directly onto another off; INSERT; . (This does not include transition elbow from rear
- 12 - VERTICAL SIDEWALL APPLICATIONS The maximum number of 90 degree elbows per side wallinstallation is four (4), (includes 7DVRT90 off back of unit) The maximum number of 45 degree elbows permitted perside wall installation is two (2). These elbows can beinstalled in either the vertical or horizo...
Page 13 - HOW TO USE THE VENT GRAPH; EXAMPLE; SIDEWALL VENTING GRAPH; STEP 1
- 13 - SEE PAGE 15 FOR VENTING REQUIREMENTS FOR SNORKELS. 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 eg: A eg: B VERTICAL DIMENSION FROM THE FLOOR OF THE UNIT TO THE CENTRE OF THE HORIZONTAL VENT PIPE Fig. 21 HOW TO USE...
Page 14 - FIRESTOP
- 14 - ,, ,, X ,, ,, STEP 2 Fig. 25. Measure wall thickness and cut adjustable zeroclearance sleeve parts to proper length (MAXIMUM 12").Adjust sleeve to minimum (9-3/8" x 9-3/8") and attach tofirestop with #8 sheet metal screws (supplied). Installfirestop assembly. #8SCREWS(2) ADJUSTABL...
Page 16 - VERTICAL THRU THE
- 16 - Fig. 36 The minimum height of the vent above the highestpoint of penetration throught the roof is 2 feet. SeeFig. 36. TYPICAL STRAIGHT-UP INSTALLATION 40 FEET (12.2m) ATTIC INSULATION SHIELD JOISTS ROOF VENT TERMINATION ATTIC INSULATION ROOF SUPPORT STORM COLLAR ROOF FLASHING 2' Min. CEILING ...
Page 17 - CRIMPED END VENTING COMPONENTS
- 17 - CRIMPED END VENTING COMPONENTS 7DVRVT - Through the wall Rear Vent Termination Starter Kit -Model 7DVSK - Sidewall Venting Starter Kit - Model 7DVSKV - Vertical Venting for 7DVSKV-A order 1/12 to 6/12 roof pitchfor 7DVSKV-B order 7/12 to 12/12 roof pitchfor 7DVSKV-F order flat roof Starter Ki...
Page 18 - Screw Holes; Crimped pipe and new twist lock pipe.; Vent Starter Kit Model 7TDVRVT must be; Note: It is not necessary to seal the vent pipe joints
- 18 - GENERAL INFORMATION ON ASSEMBLING THE TWIST LOCK VENT PIPES When using CFM Majestic twist lock pipe it is not neces-sary to use silicone to seal the twist lock joints. The onlyareas that need silicone are the collars on the fireplace,the telescoping pipe (if used) and the horizontal termina-t...
Page 19 - STEP 5
- 19 - Fig. 40 Combustible Walls. Cut a 10-3/8"H x 9-3/8"W (265mmx 240mm) hole through the exterior wall and frame asshown. Fig. 40. Non-Combustible Walls: Hole opening must be 7.5"(190mm) in diameter. To locate hole centre consult withappropriate fireplace specifications, page 4. (240mm...
Page 22 - VENT SIDEWALL INSTALLATION; STEP 4
- 22 - VENT SIDEWALL INSTALLATION *IMPORTANT* Minimum clearance between vent pipesand combustible materials is one (1") inch (25 mm) onbottom, sides and top. Vent Starter Kit 7TDVSK, plus TransitionE l b o w 7 T D V R T 9 0 m u s t b e u s e d i nVertical Sidewall installations. The 4" pipe ...
Page 23 - BELOW GRADE INSTALLATIONS; Ensure sidewall venting clearances are observed.
- 23 - ,, ,, X ,, ,, S e a l i n g v e n t p i p e a n dfirestop gaps with hightemperature sealant willr e s t r i c t c o l d a i r b e i n gdrawn in around fireplace. Fig. 54 STEP 5 (Fig. 54) Use the appropriate lengthof pipe section – telescopic or fixed– and install. The 20" section ofpipe w...
Page 26 - TWIST LOCK VENTING COMPONENTS
- 26 - TWIST LOCK VENTING COMPONENTS 7DVRVT - Through the wall Rear Vent Termination Starter Kit -Model 7TDVSK - Sidewall Venting Starter Kit - Model 7TDVSKV - Vertical Venting for 7TDVSKV-A order 1/12 to 6/12 roof pitchfor 7TDVSKV-B order 7/12 to 12/12 roof pitchfor 7TDVSKV-F order flat roof Starte...
Page 27 - GLASS FRAME REMOVAL; Let the fireplace cool if it has been operating.; OPERATING INSTRUCTIONS; GENERAL GLASS INFORMATION; Care must be taken to avoid breakage of the glass.; LOUVRE REMOVAL
- 27 - GLASS FRAME REMOVAL 1. Shut off gas. 2. Let the fireplace cool if it has been operating. 3. Remove top louvre. (See Louvre Removal) 4. Open the lower louvre assembly. 5. Release the two clamps at the bottom of the windowframe by pulling down on the clamp handles. 6. Lift off the glass frame a...
Page 29 - LOGS MAY BE HOT; FLAME CHARACTERISTICS; PSE PILOT
- 29 - The burner and control system consists of: • burner tube • gas orifices • pilot assembly • thermopile • millivolt gas valve Most of these components may require only an occasionalcheckup and cleaning and some may require adjustment.If repair is necessary, it should be performed by aqualified ...
Page 30 - FOR YOUR SAFETY READ BEFORE LIGHTING; TO TURN OFF GAS TO FIREPLACE; LIGHTING AND OPERATING INSTRUCTIONS; LIGHTING INSTRUCTIONS; EURO SIT
- 30 - 4. Push in gas control knob slightlyand turn clockwise to "OFF". Do not force. 5. Close control access panel. 10. Push the control knob all the way in and hold. Immediately light the pilot by repeatedly depressingthe piezo spark ignitor until a flame appears.Continue to hold the contr...
Page 31 - START; CHECK; TROUBLE SHOOTING THE GAS CONTROL SYSTEM; HONEYWELL MILLIVOLT VALVE
- 31 - • GAS SUPPLY ON • SUPPLY LINE HOOKED UP• SHUTOFF VALVE OPEN NO NO NO NO • LOCKOUT HAS ENGAGED. WAIT 60 SECONDS AND TRY AGAIN.• FOR SPARK AT ELECTRODE WHILE DEPRESSING PIEZO — 1/8" GAP TO PILOT HOOD NEEDED.• ALL WIRING CONNECTIONS• REPLACE PIEZO IGNITOR • FOR AIR IN THE LINES• THERMOPILE N...
Page 32 - SIT 820 NOVA MILLIVOLT VALVE; GLASS DOOR TO BE REMOVED BEFORE SERVICE WORK
- 32 - TROUBLE SHOOTING THE GAS CONTROL SYSTEM SIT 820 NOVA MILLIVOLT VALVE START CHECK GLASS DOOR TO BE REMOVED BEFORE SERVICE WORK GAS SUPPLY ON • SHUTOFF VALVE OPEN• CONFIRM GAS HOOK-UP LIGHT PILOT WITH PIEZO IGNITION • ELECTRODE GAP MIN. 1/8"• ELECTRODE CRACKED• ELECTRODE CABLE ATTACHED• PIE...
Page 33 - REPLACEMENT PARTS LIST; ESCRIPTION; S E E R A T I N G P L A T E F O R O R I F I C E S I Z E
- 33 - REPLACEMENT PARTS LIST D ESCRIPTION BHDR36 1. Log Set Complete 10001818 1a. Log Front BH1 1b. Log Rear BH2 1c. Log Top Left BH3 1d. Log Top Right BH4 2. Lava Rock (Package) 10001454 3. Burner Tube Assembly 10001811 4a. Orifice Burner (Nat) S E E R A T I N G P L A T E F O R O R I F I C E S I Z...
Page 34 - REPLACEMENT PARTS
- 34 - 27 26 24 25 22 4 a/b 17 16 11 9 15 13 31 32 33 30 30 29 21 23 19 a/b 5 a/b 34 2 28 36 35 12 LO HI PILOT ADJ PILOT ON OFF 7 a/b 20 a/b 18 8 a/b 3 6 a/b 10 15 14 #1 - COMPLETE LOG SET #1 - COMPLETE LOG SET 1c 1d 1b 1a REPLACEMENT PARTS
Page 35 - OPTIONAL FAN KIT - FK24; WIRING INSTRUCTIONS; OPTIONAL BAY WINDOW INSTALLATION; Remove existing bottom louvre and hinges from fire-
- 35 - 1. Slide fan assembly from the left side into fireplaceopening, line up mounting holes with screw studs onback of fireplace and fasten with #10-24 hex nuts. 2. Install thermal sensor on bottom of firebox using#10-24 hex nuts. 3. (Option A) - Place electronic fan speed controlbox on bottom of ...
Page 36 - To install the Frame Window Screen:; OPTIONAL REMOTE CONTROL
- 36 - OPTIONAL CERAMIC REFRACTORY INSTALLATION 6. Hang Bay Window Frame assembly over existing glass frame. Do not remove existing glass frame 7. Re-install top louvre assembly. Remove all plastic from brass trims 8. Open the Bottom Bay Louvre door and screw two (2) self tapping screws (as per step...