Page 2 - Dutchwest Direct Vent / Natural Vent Gas Heater; Table of Contents
2 Dutchwest Direct Vent / Natural Vent Gas Heater 30001935 Table of Contents PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a Dutchwest stove. IMPORTANT: Read all instructions and warnings carefully before starting ...
Page 3 - General Information
3 Dutchwest Direct Vent / Natural Vent Gas Heater 30001935 General Information The Dutchwest Direct Vent/Natural Vent Room Heater, Model Nos. 3070, 3071, 3072 and 3073, is a vented gas appliance listed to the ANSI standard Z21.88b-2001 and CSA-2.33b-2001 for Vented Room Heaters, and CSA 2.17-M91, Ga...
Page 4 - Dutchwest Direct Vent / Natural Vent Dimensions; CL; Dutchwest dimensions.; Attention
4 Dutchwest Direct Vent / Natural Vent Gas Heater 30001935 Dutchwest Direct Vent / Natural Vent Dimensions CL Valve Inlet 23" (584mm) 6 ��� " (172mm) 24 ��� " (622mm) CL Valve Inlet 1935Dutchwest DV/NVdimensions5/15/03 28 ��� " (721mm) 12 ��� " (318mm) 17" (419mm) 4 ��� "...
Page 5 - Installation Requirements; Locating the Stove; We do not recommend the use of wallpaper; Dutchwest; Direct Vent System Only; A. Flat on corner wall; Possible stove locations.; Clearance Requirements; Always maintain required clear-
5 Dutchwest Direct Vent / Natural Vent Gas Heater 30001935 Installation Requirements The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 - latest edition. (EXCEP-TION: Do not derate this appliance for altitude. Main-t...
Page 6 - Stove Clearance
6 Dutchwest Direct Vent / Natural Vent Gas Heater 30001935 Parallel Installation: Minimum Clearance and Flue Centerline, Direct Vent and Natural Vent ST128bStardanceflue centerline9/28/00 djt C L C L B D C A ST128c Stove Clearances A: 4” (102 mm) B: 4” (102 mm) Pipe Centerlines C: 15 ¹⁄₂ ” (395 mm) ...
Page 7 - Input; Gas Specifications; Dutchwest Direct Vent/Natural Vent; High Elevations; Horizontal Termination -; Horizontal vent termination window.
7 Dutchwest Direct Vent / Natural Vent Gas Heater 30001935 Max. Min. Input Input Model Fuel Gas Control BTU/h BTU/h 2465 Nat Millivolt 28,000 20,000 2466 Prop Millivolt 28,000 19,000 Gas Specifications Weight: Fully assembled; 202 lbs. Gas Inlet and Manifold Pressures Natural LP (Propane) Inlet Minim...
Page 8 - Vertical Termination - Direct Vent ONLY; NOTE: The restrictor plate supplied; A vertically terminated vent system must; Vertical vent termination window.; Vent Termination Clearances; IMPORTANT
8 Dutchwest Direct Vent / Natural Vent Gas Heater 30001935 Vertical Termination - Direct Vent ONLY A vertical vent system must terminate no less than 8’ (2.44m) and no more than 40’ (12m) above the appli-ance flue collar. A 2 ¹⁄₄ ” restrictor plate (supplied) must be used where specified in all vertic...
Page 9 - Venting Termination Clearances; • Venting terminals shall not be recessed into a wall or; Location of Vent Termination
9 Dutchwest Direct Vent / Natural Vent Gas Heater 30001935 Venting Termination Clearances Your stove is approved to be vented either through the side wall, or vertical through the roof.• This unit does not require any opening for in-spection of vent pipe. • Only CFM Corporation and Simpson DuraVent ...
Page 10 - Canadian Installations; General Venting Information - Termination Location
10 Dutchwest Direct Vent / Natural Vent Gas Heater 30001935 Canadian Installations 1 US Installations 2 V V V V V V V X X X D E B B B C B M B A J K F L VENT TERMINATION AIR SUPPLY INLET AREA WHERE TERMINAL IS NOT PERMITTED H I ����� ������ Operable Operable Fixed Closed V B CFM145aDV Termin Location...
Page 11 - Termination clearances.; Venting Requirements - Natural Vent Only; Venting Runs; NOTE: When venting staight vertical, without any; Vent termination window - Natural Vent ONLY.; Outside Corner; Termination Clearances; with no side wall; of Caps
11 Dutchwest Direct Vent / Natural Vent Gas Heater 30001935 Fig. 10 Termination clearances. Venting Requirements - Natural Vent Only FP567NVBR/NVBC VENTING RUNS11/12/97 Venting Runs Horizontal Run (in feet) Vertical Run (in feet) (Measured from top of the unit before any elbow) A: Vertical installat...
Page 12 - Venting Requirements and Options -
12 Dutchwest Direct Vent / Natural Vent Gas Heater 30001935 Venting Requirements and Options - Direct Vent ONLY Approved Vent System Components The Dutchwest Heater must be vented to the outdoors through an adjacent exterior wall or through the roof. The venting system must be comprised of the appro...
Page 13 - Install the Optional Fan; Fan kit components.; Remove the rear skirt insert panel at the bottom of; Remove rear skirt insert.; attach fan; Attach the fan assembly and the snapstat.
13 Dutchwest Direct Vent / Natural Vent Gas Heater 30001935 Install the Optional Fan If you are installing the optional convection Fan Kit #2767 (FK26), continue here. If you are not installing a Fan Kit, go to Page 14, Venting System Assembly.1. The fan kit includes a Blower Assembly and a Rheo- st...
Page 14 - Venting System Assembly - Direct Vent; For Canadian installations:; Install the Vent Adapter Pipe; Install the restrictor plate only if required for the vent-; Dry fit the Outer pipe assembly; attach inner pipe; Connect the inner starter with the next section of in-; attach inner assy; Attach inner assembly to flue collar.; attach inner assy
14 Dutchwest Direct Vent / Natural Vent Gas Heater 30001935 Venting System Assembly - Direct Vent General Information The Dutchwest is approved for installation only with the vent components listed on Page 12. Follow the vent component instructions exactly. For U.S. installations: The venting system...
Page 15 - Discard the inner starter pipe; dura vent; Simpson DuraVent - install inner adapter pipe.; DW dura vent; Simpson DuraVent - install outer adapter pipe.; Side Wall Termination Assembly; Vent Opening; CFM System; Locate vent opening.; Assemble the wall sleeve and firestop.
15 Dutchwest Direct Vent / Natural Vent Gas Heater 30001935 Install the Vent Adapter Pipe (Simpson Dura-Vent Components)1. Install the Restrictor Plate. Consult the ‘Vent Run Specifications’ on Page 8 to determine whether the restrictor plate is needed. If so, put the restrictor plate in place within...
Page 16 - For DuraVent pipe only:; DW; Determine the vertical pipe length.; measure thru wall; Measure the horizontal length.; install pipe thru wall; Install the horizontal pipe and wall plate parts.; install wall terminal; Install the vent terminal.
16 Dutchwest Direct Vent / Natural Vent Gas Heater 30001935 For DuraVent pipe only: Install vent pipe by align- ing the locking system together, sliding the pipes together and twisting clockwise. • Install 90° elbow. Twist lock as before. • Slide the wall plate over horizontal run before at- taching...
Page 17 - Vent Termination Below Grade; If the; install snorkel; snorkel detail; Use extension brackets to mount snorkel against; Vent Assembly
17 Dutchwest Direct Vent / Natural Vent Gas Heater 30001935 Vent Termination Below Grade Install Snorkel Kit #7FSDVSKS when it is not possible to meet the required vent termination clearances of 12” (305mm) above grade level. The snorkel kit will allow installation depth of down to 7” (178mm) below ...
Page 18 - vent thru ceiling; Install firestops and attic insulation shield.; vent thru roof; Roof support and flashing.; Venting System Assembly - Natural Vent; Decorative 7” pipe may be fitted around the B-vent; Install the Vent Pipe
18 Dutchwest Direct Vent / Natural Vent Gas Heater 30001935 8. Install appropriate pipe sections until the vent run reaches above the flashing. The enlarged ends of the vent sections always face downward. 9. Install the storm collar and seal around the joints. (Fig. 31) 10. Add additional vent length...
Page 19 - Install draft hood adapter.; Install the Log Set; Stardance; Connect the Gas Supply Line; CAUTION
19 Dutchwest Direct Vent / Natural Vent Gas Heater 30001935 Attach the first section of venting to the draft hood. De-pending on the length of the individual venting sections and the lengths of the decorative pipe (if installed), you may need to slip the decorative pipe over the venting sections befo...
Page 20 - Burner Information; Air Shutter Adjustment Instructions; In order to connect Natural Gas,; Air Shutter Adjustment; Model; Remove stove front.; Jefferson; Remove rear log bracket and left and right log
20 Dutchwest Direct Vent / Natural Vent Gas Heater 30001935 In the U.S.; Gas connection should be made in ac- cordance with current National Fuel Gas Code, ANSI Z223.1/NFPA 54. Since some municipalities have additional local codes, be sure to consult your local authority. In Canada; consult the loca...
Page 21 - Air shutter adjusted.; air shutter adjust; Be sure to maintain 90° angle at left burner leg.; Complete the Assembly; attach switch assy; Attach switch assembly to rear shroud.; attach switch; Attach switch wires to valve.
21 Dutchwest Direct Vent / Natural Vent Gas Heater 30001935 8. The air shutter is located on the bottom of the burner to the left. (Fig. 37) Unfasten the two nuts holding the shutter in place. The shutter may be adjusted between the factory adjusted 1/2” to fully open. Reassemble the shutter to allo...
Page 22 - Thermostat; Install the wall thermostat in the desired location and; Install the Stove Front; handle assy; Insert handle stub into hole in front. Secure with 3/8”; Install the front plate.
22 Dutchwest Direct Vent / Natural Vent Gas Heater 30001935 Thermostat Connection (optional) Use only a thermostat rated for 500 millivolts.Check the table below for the appropriate gauge ther-mostat wire to use for the length of lead required in your installation. Thermostat Wire / Gauge Maximum Ru...
Page 23 - Operation; Your First Fire; Pilot assembly location.; Flame & Temperature Adjustment; Flame adjustment knob for Honeywell valve.; Flame Characteristics; Pilot flame; Correct pilot and burner flame patterns.
23 Dutchwest Direct Vent / Natural Vent Gas Heater 30001935 Operation Your First Fire Read these instructions carefully and familiarize your-self with the burner controls. Locate the pilot assembly, Figure 45. Follow the lighting instructions on Page 25 exactly. During the first fire, it is not unusua...
Page 24 - FOR YOUR SAFETY READ BEFORE LIGHTING; Follow the gas supplier’s instructions.; To Turn Off Gas To Heater; Lighting and Operating Instructions; Lighting Instructions; Euro SIT; Lighting instructions
24 Dutchwest Direct Vent / Natural Vent Gas Heater 30001935 3. Open control access panel.4. Push in gas control knob slightly and turn clock- wise to “OFF”. Do not force. 5. Close control access panel. 1. STOP! Read the safety information above. 2. Turn off all electrical power to the fireplace.3. Fo...
Page 25 - Troubleshooting / Honeywell #8420 Gas Control System; SYMPTOM
25 Dutchwest Direct Vent / Natural Vent Gas Heater 30001935 Troubleshooting / Honeywell #8420 Gas Control System NOTE: Before troubleshooting the gas control system, be sure the external gas shutoff is in the “ON” position. WARNING: REMOVE THE GLASS PANEL BEFORE PERFORMING ANY GAS CONTROL SERVICE WO...
Page 26 - Fuel Conversion Instructions; Attach the gas line to the left side of the valve.; Conversion Precautions; Honeywell Valve
26 Dutchwest Direct Vent / Natural Vent Gas Heater 30001935 Fuel Conversion Instructions WARNING! This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If ...
Page 27 - Pilot Orifice Conversion; Remove mounting screws, pressure regulator tower; SIT; gas conversion; Remove pilot orifice.; Remove pilot hood. (Your pilot may have a different; Gas Conversion; Remove pilot orifice.
27 Dutchwest Direct Vent / Natural Vent Gas Heater 30001935 Pilot Orifice Conversion 1. Locate pilot. (Fig. 49)2. Replace pilot orifice. Pilot Type 1 • Remove pilot hood by lifting up. (Fig. 53) Do not remove snap ring to remove pilot hood. NOTE: It is not necessary to remove the pilot tube for conver...
Page 28 - Replace burner. Slide the burner in at an angle; Table 2. Injector Orifice Size Matrix
28 Dutchwest Direct Vent / Natural Vent Gas Heater 30001935 21. Replace burner. Slide the burner in at an angle with left side lower than the right side. Slide the left side onto the injectors, making sure the burner leg remains at a 90° angle to the base. Lower the right hand side down in to place....
Page 29 - Maintenance; ERATE THE HEATER WITH DAMAGED LOGS.; Remove the stove front.; glass swivel latch; Release the latches to release the glass frame.
29 Dutchwest Direct Vent / Natural Vent Gas Heater 30001935 Maintenance Your Dutchwest Gas Heater will provide years of ser-vice with minimal upkeep. The following procedures will help ensure that your stove continues to function properly. Annual System Inspection Have the entire heater and venting ...
Page 30 - Gasket Replacement; Determine the correct length of gasket by laying it; Check the Gas Flame Regularly; glass gasket detail; Wrap the gasket material around the outside edge of; Inspect the Vent System Annually; Correct flame pattern.; Stove Disassembly
30 Dutchwest Direct Vent / Natural Vent Gas Heater 30001935 Gasket Replacement The Dutchwest Gas Heater uses a ‘tadpole’ type gasket to seal between the glass panel and the frame. In time, this gasket can become brittle and compressed and should be replaced. New gasket is available from your dealer....
Page 31 - Wiring Diagrams; On/Off switch and optional thermostat circuit.; IF ANY OF THE ORIGINAL WIRE, AS; Draft hood adapter wiring.; AN; BLK; FK26 wiring diagram; Schematic Diagram
31 Dutchwest Direct Vent / Natural Vent Gas Heater 30001935 Wiring Diagrams OFF ON Thermostat (Optional) Therm opile Black Black Millivolt Gas Valve St124b on/off/switch wiring 1/11/00 djt TP/TH TP TH On/Off Switch Wiring ST124b Thermostat (Optional) Therm opile Black Black Millivolt Gas Valve St124...
Page 32 - Small Lava Rock Package
32 Dutchwest Direct Vent / Natural Vent Gas Heater 30001935 1a 1b 1c 2 10 12 11 PILOT ON OFF PILOT ADJ LO HI 23 27 28 32 CEMENT 34 35 1 3 4 6 7 5 8 13a,b 15a 17 19 14 18 20 21 15b 16a,b,c,d 25 26 24 33 29 31 9 22 30 1935Dutchwestparts5/16/03 djt 30 36 37a,b 38 CFM Corporation reserves the right to m...
Page 33 - Pilot Top Convertible; Fuel Conversion Kits
33 Dutchwest Direct Vent / Natural Vent Gas Heater 30001935 Ref. Description Dutchwest Dutchwest Direct Vent / Natural Vent Gas Heater Models 2465, 2466 (continued) 10. Glass, DV25 1601691 11. Glass Frame Assembly - SDV30 30000127 12. Gasket, Glass - Med. Knit - RDV40 1203702 13a. Valve RN Honeywell...
Page 34 - Optional Accessories; Fan Kits; Refer to Page 13 for installation instructions.; Remote Controls; ON/OFF and Temperature; Decorative Rings
34 Dutchwest Direct Vent / Natural Vent Gas Heater 30001935 Optional Accessories Fan Kits FK26 Fan The FK26 fan helps distribute heated air from within the firebox out into the room. The fan is controlled by a snapstat that turns power on and off as the firebox tem-perature rises above and falls below...
Page 35 - LIMITED LIFETIME WARRANTY; BASIC WARRANTY; IF WARRANTY SERVICE IS NEEDED...; ) Contact your supplier. Make sure you have your warranty, your
35 Dutchwest Direct Vent / Natural Vent Gas Heater 30001935 LIMITED LIFETIME WARRANTY PRODUCT COVERED BY THIS WARRANTYAll Dutchwest gas stoves equipped with an Insta-Flame Ceramic Burner. BASIC WARRANTY CFM Corporation Company (hereinafter referred to collectively as the Company) warrants that your ...
Page 36 - Efficiency Ratings; CFM Corporation
Efficiency Ratings Model EnerGuide Ratings Fireplace Efficiency (%) 2465 63.0 2466 63.0 410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 800-668-5323 • www.cfmcorp.com CFM Corporation