Page 2 - Important Safety Warnings; UPS Location Warnings; UPS Connection Warnings
2 Important Safety Warnings SAVE THESE INSTRUCTIONS. This manual contains important instructions and warnings that should be followed during the installation andmaintenance of all Tripp Lite SmartOnline 3-Phase UPS Systems and their batteries. UPS Location Warnings • Install your UPS indoors, away f...
Page 3 - Control Panel; FRONT PANEL; SELECT
3 Control Panel There are two separate UPS system modules: a power module and a battery module. Familiarize yourself with the location and function ofthe features on each module before installing and operating your UPS system. The power module is the only module which includes frontpanel features. F...
Page 4 - Rear Panels
4 Rear Panels 17 18 Battery Module Rear Panel Power Module Rear Panel 13 7 6 8 15 4 12 2 14 9 10 5 1 11 3 16 REFER TO USER'S MANUAL FOR TORQUING SPECIFICATIONS, USE COPPER CONDUCTORS ONLY. UTILISER SEULEMENT LES CONDUCTEURS DE CUIVRE. 1. Manual Bypass Switch: This switch is used in one step of putti...
Page 5 - Installation; INVERTER OPERATION DIP SWITCH SETTINGS; Input Frequency Selection
5 Rear Panels (continued) 10. “Battery Start” Switch: This momentary rocker switch allows you to “cold-start” your UPS and use it as a stand-alone power source when utility-supplied AC power is not present. The switch enables the UPS’s DC/AC Inverter. Before “cold-starting” your UPS, make sureyour p...
Page 6 - Operational Mode Selection; UPS LOCATION
6 Installation (continued) Operational Mode Selection (DIP Switch #4) The "On-Line" Mode provides on-line operation with zero transfer time. The "Economy" Mode provides line-interactive operation forincreased efficiency when on-line protection is unnecessary, thus reducing operating ...
Page 7 - EXTERNAL BATTERY MODULE CONNECTION (required); BATTERY CONDITION VERIFICATION
7 Installation (continued) EXTERNAL BATTERY MODULE CONNECTION (required) Connect the battery module to the power module. Consult the owner's man-ual that came with your battery module. Fully insert the connector on the endof the battery module's cable into the connector on the rear panel of thepower...
Page 8 - TURNING THE UPS ON; TURNING THE UPS OFF
8 Operation (Normal Conditions) TURNING THE UPS ON • Make sure the UPS is properly installed (see Installation section) and the Manual Bypass Key is set to NORMAL. • Turn the AC Input and Bypass AC Input Circuit Breakers ON. • If your AC input is providing power normally within your selected range (...
Page 12 - SWITCHING UPS TO “NORMAL” MODE; Communications
12 OPERATION OF MANUAL BYPASS SWITCH Turn this switch to “BYPASS” before performing any maintenance on the UPS with the connected load supported. Connected equipmentwill receive filtered AC mains power, but will not receive battery power in the event of a blackout. SWITCHING UPS TO “BYPASS” MODE • T...
Page 13 - DRY CONTACT INTERFACE
13 Communications (continued) AS-400 INTERFACE This female DB9 port connects your UPS to an IBM AS-400 computer via the included AS-400 cable. The port uses AS-400communications to report UPS status. It can be used to allow anAS-400 to automatically save open files and shut down its operat-ing syste...
Page 14 - -Year Limited Warranty
14 Communications (continued) REMOTE EMERGENCY POWER OFF (EPO) This optional feature is only for those applications which require connection to a facility's Emergency Power Off (EPO)circuit. When thepower module is connected to this circuit, it enables emergency shutdown of the output. Using the inc...
Page 15 - Specifications
15 The specifications listed below are for Tripp Lite model SU10K3/1X which includes two modules: a power module and a battery mod-ule. The two modules are also sold separately with their own individual model numbers: power module (individual model #:SU10K3/1INTPM) and battery module (individual mod...