38 TeslaIrvine, CA 92618Phone: (949) 679-8000 TigerStack III 10/100Installation Guide From SMC’s Tiger line of feature-rich workgroup LAN solutions June 2005 Pub. # 150200037700A
L IMITED W ARRANTY ii WARRANTIES EXCLUSIVE: IF AN SMC PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE, CUSTOMER’S SOLE REMEDY SHALL BE REPAIR OR REPLACEMENT OF THE PRODUCT IN QUESTION, AT SMC’S OPTION. THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER WARRANTIES OR CONDITI...
i C OMPLIANCES FCC - Class A This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause interference to radio commu-nications. It has been tested and found to comply with the limits for a Class A computin...
C OMPLIANCES iii Australia AS/NZS 3548 (1995) - Class A SMC contact for products in Australia is: SMC Communications Pty. Ltd.Suite 18, 12 Tryon Road, Lindfield NSW2070,Phone: 61-2-94160437Fax: 61-2-94160474 Safety Compliance Warning: Fiber Optic Port Safety Avertissment: Ports pour fibres optiques ...
C OMPLIANCES iv • The socket outlet must be near to the unit and easily accessible. You can only remove power from the unit by disconnecting the power cord from the outlet. • This unit operates under SELV (Safety Extra Low Voltage) conditions according to IEC 60950. The conditions are only maintaine...
C OMPLIANCES vi • Die Netzsteckdose muß in der Nähe des Geräts und leicht zugänglich sein. Die Stromversorgung des Geräts kann nur durch Herausziehen des Gerätenetzkabels aus der Netzsteckdose unterbrochen werden. • Der Betrieb dieses Geräts erfolgt unter den SELV-Bedingungen (Sicherheitskleinstspan...
C OMPLIANCES vii Warnings (in German) Environmental Statement The manufacturer of this product endeavours to sustain an environmentally-friendly policy throughout the entire production process. This is achieved though the following means:• Adherence to national legislation and regulations on environ...
C OMPLIANCES viii Audience This guide is for system administrators with a working knowledge of network management. You should be familiar with switching and networking concepts.Zielgruppe Dieser Anleitung ist fuer Systemadministratoren mit Erfahrung im Netzwerk-mangement. Sie sollten mit Switch- und...
ix T ABLE OF C ONTENTS 1 About the TigerStack III 10/100 . . . . . . . . . . . . . . . . . . . 1-1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 Switch Architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
T ABLE OF C ONTENTS xi A PPENDICES : A Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1 Diagnosing Switch Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1 Diagnosing Power Problems with the LED Indicators . . . . . . . . . A-2 Powe...
xii T ABLES Table 1-1 Port Status LED Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5Table 1-2 System Status LED Indicators . . . . . . . . . . . . . . . . . . . . . . . . 1-7Table 3-1 Serial Cable Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-13Table 4-...
xiii F IGURES Figure 1-1 Front and Rear Panels. . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 Figure 1-2 Port LED Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 Figure 1-3 System LED Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7 Figure 1-4 S...
1-1 C HAPTER 1 A BOUT THE T IGER S TACK III 10/100 Overview SMC’s TigerStack III 10/100 SMC6826MPE is a 24-Port Fast Ethernet PoE Switch with 24 10BASE-T/100BASE-TX RJ-45 ports and two combination ports — 10/100/1000BASE-T ports that operate in combination with Small Form Factor Pluggable (SFP) tran...
A BOUT THE T IGER S TACK III 10/100 1-2 Figure 1-1 Front and Rear Panels. Switch Architecture The switch employs a wire-speed, non-blocking switching fabric. This permits simultaneous wire-speed transport of multiple packets at low latency on all ports. The switch also features full-duplex capabilit...
O VERVIEW 1-3 from the switch over the Ethernet cable without requiring its own separate power source. This capability gives network administrators centralized power control for devices such as IP phones and wireless access points, which translates into greater network availability. For each attache...
A BOUT THE T IGER S TACK III 10/100 1-4 Description of Hardware 10/100BASE-T Ports The PoE switch base unit contains 24 10BASE-T/100BASE-TX RJ-45 ports. All ports support automatic MDI/MDI-X operation, so you can use straight-through cables for all network connections to PCs or servers, or to other ...
D ESCRIPTION OF H ARDWARE 1-5 Port and System Status LED Indicators The switch base unit also includes a display panel for key system and port indications that simplify installation and network troubleshooting. The LED indicators, which are located on the front panel for easy viewing, are shown belo...
D ESCRIPTION OF H ARDWARE 1-7 Figure 1-3 System LED Indicators Table 1-2 System Status LED Indicators LED Condition Status PWR On Green Unit’s internal power supply is operating normally. Off Unit has no power connected. Diag On Green System diagnostic test successfully completed. Flashing Green Sys...
A BOUT THE T IGER S TACK III 10/100 1-8 Stack Master Button The unit also includes a Stack Master button shown in the following diagram. Figure 1-4 Stack Master Button The Stack Master button enables one switch in the stack to be selected as the master. Stacking On Green This switch is acting as the...
D ESCRIPTION OF H ARDWARE 1-9 Mode PoE/Link Button The Mode PoE/Link button is located on the front panel. Figure 1-5 Mode Selection The Mode PoE/Link button is used to toggle between the two port status LED display modes (see “Port Status LED Indicators” on page 1-5). Pressing this button changes f...
A BOUT THE T IGER S TACK III 10/100 1-10 together using stacking cables (one stacking cable is included with each optional stacking transceiver). The push button on the switch’s front panel enables one switch in the stack to be selected as the master. (See “Stack Master Button” on page 1-8.) Power S...
F EATURES AND B ENEFITS 1-11 • Unshielded (UTP) cable supported on all RJ-45 ports: Category 3 or better for 10 Mbps connections, Category 5 or better for 100 Mbps connections, and Category 5, 5e or 6 for 1000 Mbps connections • IEEE 802.3-2002 Ethernet, Fast Ethernet, Gigabit Ethernet, and flow con...
A BOUT THE T IGER S TACK III 10/100 1-12 Management • “At-a-glance” LED indicators for easy troubleshooting • Network management agent: - Manages switch (or entire stack) in-band or out-of-band - Supports console, Telnet, SSH, SNMP v1/v2c/v3, 4 RMON groups and web-based interface
2-1 C HAPTER 2 N ETWORK P LANNING Introduction to Switching A network switch allows simultaneous transmission of multiple packets via non-crossbar switching. This means that it can partition a network more efficiently than bridges or routers. The switch has, therefore, been recognized as one of the ...
N ETWORK P LANNING 2-2 Application Examples The switch is not only designed to segment your network, but also to provide a wide range of options in setting up network connections. Some typical applications are described below. Supplying PoE The switch is an excellent choice for supplying power to co...
A PPLICATION E XAMPLES 2-3 Collapsed Backbone The switch is an excellent choice for mixed Ethernet, Fast Ethernet, and Gigabit Ethernet installations in which significant growth is expected in the near future. You can easily build on this basic configuration, adding direct full-duplex connections to...
N ETWORK P LANNING 2-4 Network Aggregation Plan With 24 parallel bridging ports (i.e., 24 distinct collision domains), the switch can collapse a complex network down into a single efficient bridged node, increasing overall bandwidth and throughput. When up to eight switch units are stacked together,...
A PPLICATION E XAMPLES 2-5 Remote Connections with Fiber Cable Fiber optic technology allows for longer cabling than any other media type. Using a 1000BASE-SX multimode fiber (MMF) SFP transceiver, you can run a link up to 550 m, a 1000BASE-LX single-mode fiber (SMF) link can run up to 5 km, and a 1...
N ETWORK P LANNING 2-6 Making VLAN Connections This switch supports VLANs which can be used to organize any group of network nodes into separate broadcast domains. VLANs confine broadcast traffic to the originating group, and can eliminate broadcast storms in large networks. This provides a more sec...
A PPLICATION N OTES 2-7 Application Notes 1. Full-duplex operation only applies to point-to-point access (such as when a switch is attached to a workstation, server or another switch). When the switch is connected to a hub, both devices must operate in half-duplex mode. 2. Avoid using flow control o...
3-1 C HAPTER 3 I NSTALLING THE S WITCH Selecting a Site Switch units can be mounted in a standard 19-inch equipment rack or on a flat surface. Be sure to follow the guidelines below when choosing a location. • The site should: - be at the center of all the devices you want to link and near a power o...
I NSTALLING THE S WITCH 3-2 • As with any equipment, using a filter or surge suppressor is recommended. Ethernet Cabling To ensure proper operation when installing the switch into a network, make sure that the current cables are suitable for 10BASE-T or 100BASE-TX operation. Check the following crit...
E QUIPMENT C HECKLIST 3-3 Equipment Checklist After unpacking this switch, check the contents to be that sure you have received all the components. Then, before beginning the installation, be sure that you have all other necessary installation equipment. Package Contents • 24-Port Fast Ethernet PoE ...
I NSTALLING THE S WITCH 3-4 Mounting This switch can be mounted in a standard 19-inch equipment rack or on a desktop or shelf. Mounting instructions for each type of site follow. Rack Mounting Before rack mounting the switch, pay particular attention to the following factors: • Temperature: Since th...
M OUNTING 3-5 Figure 3-2 Attaching the Brackets 2. Mount the device in the rack, using four rack-mounting screws (not provided). Figure 3-3 Installing the Switch in a Rack 3. If installing a single switch only, turn to “Connecting to a Power Source” at the end of this chapter. 4. If installing multi...
I NSTALLING THE S WITCH 3-6 Montage (Rack Mounting Instructions - German) Switch-Einheiten können an ein standardmäßiges 19-Zoll Einrichtungsrack, einen Arbeitstisch oder ein Regal montiert werden. Folgend finden Sie die Montageanweisungen für jeden Positionstyp. Rack-Montage Beachten Sie die folgen...
M OUNTING 3-7 Desktop or Shelf Mounting 1. Attach the four adhesive feet to the bottom of the first switch. Figure 3-4 Attaching the Adhesive Feet 2. Set the device on a flat surface near an AC power source, making sure there are at least two inches of space on all sides for proper air flow. 3. If i...
I NSTALLING THE S WITCH 3-8 Installing an SFP Transceiver Figure 3-5 Installing an SFP Transceiver The SFP slots support the following optional SFP transceivers: • 1000BASE-SX • 1000BASE-LX • 1000BASE-LH To install an SFP transceiver, perform the following steps: 1. Consider your network and cabling...
S TACKING S WITCHES 3-9 Stacking Switches The switch supports stacking up to eight units through an optional SFP stacking transceiver. Each stacking connection provides a 2 Gbps high-speed link using USB stacking cables. The stacking transceiver must be installed in the port 25 SFP slot. Each stacki...
I NSTALLING THE S WITCH 3-10 Connecting Switches in a Stack Figure 3-7 Connecting Switches in a Stack Note: The stacking transceiver must only be installed in the port 25 SFP slot. To connect up to eight switches in a stack, perform the following steps: 1. Install SFP stacking transceivers into the ...
I NSTALLING THE S WITCH 3-12 Connecting to a Power Source To connect a switch to a power source: 1. Insert the power cable plug directly into the AC socket located at the back of the switch. Figure 3-8 Power Socket 2. Plug the other end of the cable into a grounded, 3-pin socket, AC power source. No...
C ONNECTING TO THE C ONSOLE P ORT 3-13 Connecting to the Console Port The DB-9 serial port on the switch’s front panel is used to connect to the switch for out-of-band console configuration. The command-line configuration program can be accessed from a terminal or a PC running a terminal emulation p...
I NSTALLING THE S WITCH 3-14 • Stop bit—One • Data bits—8 • Flow control—none
4-1 C HAPTER 4 M AKING N ETWORK C ONNECTIONS Connecting Network Devices The switch is designed to be connected to 10 or 100 Mbps network cards in PCs and servers, as well as to other switches and hubs. It may also be connected to remote devices using the optional 1000BASE-X, or 100BASE-FX SFP transc...
T WISTED -P AIR D EVICES 4-3 Cabling Guidelines The RJ-45 ports on the switch support automatic MDI/MDI-X pinout configuration, so you can use standard straight-through twisted-pair cables to connect to any other network device (PCs, servers, switches, routers, or hubs). See Appendix B for further i...
M AKING N ETWORK C ONNECTIONS 4-4 3. If the device is a network card and the switch is in the wiring closet, attach the other end of the cable segment to a modular wall outlet that is connected to the wiring closet. (See the section “Network Wiring Connections” on page 4-4) Otherwise, attach the oth...
T WISTED -P AIR D EVICES 4-5 Figure 4-2 Network Wiring Connections Equipment Rack(side view) Switch Patch Panel Punch-Down Block Wall 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 26 Console 25 1 2 11 12 13 14 23 24 Link/Act PoE 25 26 Pwr Diag Stack Mode PoE / Link RPS
M AKING N ETWORK C ONNECTIONS 4-6 Fiber Optic Devices An optional slide-in 1000BASE-SX, 1000BASE-LX, 1000BASE-LH, or 100BASE-FX SFP transceiver may be used for backbone or remote connections, or for connecting to a high-speed server. Each single-mode fiber optic port requires 9/125 micron single-mod...
C ONNECTIVITY R ULES 4-7 3. Connect one end of the cable to the LC port on the switch and the other end to the port on the other device. Since LC connectors are keyed, the cable can be attached in only one orientation. Figure 4-3 Making Fiber Port Connections 4. As a connection is made, check the gr...
M AKING N ETWORK C ONNECTIONS 4-8 1000BASE-T Cable Requirements All Category 5 UTP cables that are used for 100BASE-TX connections should also work for 1000BASE-T, providing that all four wire pairs are connected. However, it is recommended that for all critical connections, or any new cable install...
C ABLE L ABELING AND C ONNECTION R ECORDS 4-9 Table 4-4 Maximum 1000BASE-LH Gigabit Ethernet Cable Length 100 Mbps Fast Ethernet Collision Domain Table 4-5 Maximum Fast Ethernet Cable Lengths 10 Mbps Ethernet Collision Domain Table 4-6 Maximum Ethernet Cable Length Cable Labeling and Connection Reco...
M AKING N ETWORK C ONNECTIONS 4-10 To best manage the physical implementations of your network, follow these guidelines: • Clearly label the opposing ends of each cable. • Using your building’s floor plans, draw a map of the location of all network-connected equipment. For each piece of equipment, i...
A-1 A PPENDIX A T ROUBLESHOOTING Diagnosing Switch Indicators Table A-1 Troubleshooting Chart Symptom Action PWR LED is Off • Internal power supply may be disconnected. Check connections between the switch, the power cord and the wall outlet. Diag LED is Amber • The system has detected a fault. Powe...
T ROUBLESHOOTING A-2 Diagnosing Power Problems with the LED Indicators The Power and RPU LED indicators work in combination to indicate power status as follows. Table A-2 Power/RPU LED Indicators Power and Cooling Problems If the power indicator does not turn on when the power cord is plugged in, yo...
I NSTALLATION A-3 Installation Verify that all system components have been properly installed. If one or more components appear to be malfunctioning (such as the power cord or network cabling), test them in an alternate environment where you are sure that all the other components are functioning pro...
T ROUBLESHOOTING A-4 Stack Troubleshooting If a stack fails to initialize or function, first check the following items: • Check that all stacking cables are properly connected. • Check if any stacking cables appear damaged. • Check that only one Master Select button is pressed in. • Check that all s...
B-1 A PPENDIX B C ABLES Twisted-Pair Cable and Pin Assignments For 10/100BASE-TX connections, the twisted-pair cable must have two pairs of wires. For 1000BASE-T connections the twisted-pair cable must have four pairs of wires. Each wire pair is identified by two different colors. For example, one w...
T WISTED -P AIR C ABLE AND P IN A SSIGNMENTS B-3 Straight-Through Wiring If the twisted-pair cable is to join two ports and only one of the ports has an internal crossover (MDI-X), the two pairs of wires must be straight-through. (When auto-negotiation is enabled for any RJ-45 port on this switch, y...
C ABLES B-4 Crossover Wiring If the twisted-pair cable is to join two ports and either both ports are labeled with an “X” (MDI-X) or neither port is labeled with an “X” (MDI), a crossover must be implemented in the wiring. (When auto-negotiation is enabled for any RJ-45 port on this switch, you can ...
C ABLES B-6 Table B-2 1000BASE-T MDI-X and MDI Port Pinouts Cable Testing for Existing Category 5 Cable Installed Category 5 cabling must pass tests for Attenuation, Near-End Crosstalk (NEXT), and Far-End Crosstalk (FEXT). This cable testing information is specified in the ANSI/TIA/EIA-TSB-67 standa...
F IBER S TANDARDS B-7 Adjusting Existing Category 5 Cabling to Run 1000BASE-T If your existing Category 5 installation does not meet one of the test parameters for 1000BASE-T, there are basically three measures that can be applied to try to correct the problem: 1. Replace any Category 5 patch cables...
C-1 A PPENDIX C S PECIFICATIONS Physical Characteristics Ports 24 10/100BASE-TX, with auto-negotiation 2 1000BASE-T/SFP combination ports Network Interface Ports 1-24: RJ-45 connector, auto MDI/X 10BASE-T: RJ-45 (100-ohm, UTP cable; Categories 3 or better)100BASE-TX: RJ-45 (100-ohm, UTP cable; Categ...
S PECIFICATIONS C-2 Power Consumption 48 Watts (Switching system)375 Watts (Power-over-Ethernet) Maximum Current 6.8 A @ 100 V AC 3.2 A @ 240 V AC LED Indicators System: PWR, Diag, RPS, StackingPorts: Link/Act, PoE Weight 5.76 kg (12.70 lbs) Size 44.0 x 41.0 x 4.3 cm (17.32 x 16.14 x 1.69 in.) Tempe...
M ANAGEMENT F EATURES C-3 Management Features In-Band Management Web, Telnet, SSH, or SNMP manager Out-of-Band Management RS-232 DB-9 console port Software Loading TFTP in-band, or XModem out-of-band Standards IEEE 802.3-2002 Ethernet, Fast Ethernet, Gigabit Ethernet,Full-duplex flow control IEEE 80...
S PECIFICATIONS C-4 Compliances CE Mark Emissions Industry Canada Class AEN55022 (CISPR 22) Class AFCC Class AIndustry Canada Class AEN55022 (CISPR 22) Class AEN 61000-3-2/3VCCI Class AC-Tick - AS/NZS 3548 (1995) Class A Immunity EN 61000-4-2/3/4/5/6/8/11 Safety CSA/CUS (CSA60950-1 & UL60950-1)T...
D-1 A PPENDIX D O RDERING I NFORMATION Table D-1 TigerStack III 10/100 Products and Accessories Product Number Description SMC6826MPE 24-port 10/100 stackable PoE switch with 2 Gigabit combination 1000BASE-T/SFP ports SMC6824S-P TigerStack III 10/100 Stacking Kit (includes 1 m stacking cable) SMCBGS...
Glossary-1 G LOSSARY 10BASE-T IEEE 802.3 specification for 10 Mbps Ethernet over two pairs of Category 3, 4, or 5 UTP cable. 100BASE-FX IEEE 802.3u specification for Fast Ethernet over two strands of 50/125, 62.5/125 or 9/125 micron core fiber cable. 100BASE-TX IEEE 802.3u specification for 100 Mbps...
G LOSSARY Glossary-2 Auto-Negotiation Signalling method allowing each node to select its optimum operational mode (e.g., speed and duplex mode) based on the capabilities of the node to which it is connected. Bandwidth The difference between the highest and lowest frequencies available for network si...
G LOSSARY Glossary-3 Fast Ethernet A 100 Mbps network communication system based on Ethernet and the CSMA/CD access method. Gigabit Ethernet A 1000 Mbps network communication system based on Ethernet and the CSMA/CD access method. Full Duplex Transmission method that allows two network devices to tr...
G LOSSARY Glossary-4 IEEE 802.3x Defines Ethernet frame start/stop requests and timers used for flow control on full-duplex links. (Now incorporated in IEEE 802.3-2002.) IEEE 802.3z Defines CSMA/CD access method and physical layer specifications for 1000BASE Gigabit Ethernet over fiber cabling. (Now...
G LOSSARY Glossary-5 Network Diameter Wire distance between two end stations in the same collision domain. Redundant Power Supply (RPS) A backup power supply unit that automatically takes over in case the primary power supply should fail. RJ-45 Connector A connector for twisted-pair wiring. Switched...
Index-1 Numerics 10 Mbps connectivity rules 4-6100 Mbps connectivity rules 4-61000 Mbps connectivity rules 4-5100BASE cable lengths 4-6100BASE-TX ports 1-310BASE cable lengths 4-610BASE-T ports 1-3 A adhesive feet, attaching 3-6air flow requirements 3-1applications central wiring closet 2-3collapsed...
SMC Networks Manuals
-
SMC Networks SMC8024L2
Manual
-
SMC Networks SMC6624M
Manual
-
SMC Networks SMC-EZ1026DT
Manual
-
SMC Networks SMC8124PL2
Manual
-
SMC Networks PL241
Manual
-
SMC Networks SMC10GXEN-LR
Manual
-
SMC Networks SMCBR14VPN
Manual
-
SMC Networks SMC-EZ109DT
Manual
-
SMC Networks SMC8728L2
Manual
-
SMC Networks Wireless Broadband Router
Manual
-
SMC Networks HNC-63-INT
Manual
-
SMC Networks RGD5C
Manual
-
SMC Networks SMC6726AL2
Manual
-
SMC Networks SMCD3G-BIZ
Manual
-
SMC Networks SMC8606T
Manual
-
SMC Networks SMC6110L2
Manual
-
SMC Networks SMC2835W
Manual
-
SMC Networks SMCNAS04
Manual
-
SMC Networks RGS4D
Manual
-
SMC Networks SMC2304WBR-AG
Manual