Page 2 - Handbook for Siemens Integral Monitoring Unit; ISSUE STATE; Source of documents is shown under Type as below.; Pages Current
Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 2 ISSUE STATE Note: Source of documents is shown under Type as below. 1=Paper, 2=VAX, 3=Microfilm, 4=Caltext Disc, 5=DECmate Disc, 6=Paper Insert, 7=MAC Disc, 8=Lifespan, 9=SUN, 10=Other, 11=Meridian The document compr...
Page 3 - SAFETY WARNING; TELECOMMUNICATIONS APPROVAL WARNING
Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 3 SAFETY WARNING In the interests of Health and Safety, when using or servicing this equipment, the following instructions must be noted and adhered to: i) Only skilled or instructed personnel with relevant technical k...
Page 4 - CONTENTS
Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 4 CONTENTS 1. INTRODUCTION..................................................................................................... 7 1.1 Purpose ...............................................................................
Page 5 - Table of Figures
Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 5 4.3.4 Switch to the Controller Handset Commands ............................................. 28 4.3.5 Perform Normal Controller Commissioning Sequence ................................ 28 4.3.6 Check IMU Current Faul...
Page 9 - GENERAL DESCRIPTION
Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 9 2. GENERAL DESCRIPTION 2.1 O VERVIEW The Integral Monitoring Unit is used with the Siemens T400, ST700 and ST800 Traffic Controllers to perform a multitude of different monitoring and control functions such as lamp m...
Page 11 - Section 3.2: Check controller processor PCB; PCB
Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 11 3. INSTALLING THE IMU RETRO-FIT KIT Note that the normal situation would be for the controller to be delivered with the Integral Monitoring Unit already installed. However, in the event of failure in one or more of ...
Page 12 - E60711 – TfL ST700P Single or Dual Near-Side Pedestrian Crossing
Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 12 Important: The IMU firmware PB581 issue 2 should not be used with T400 firmware issue 6 (or earlier). Other issues of PB581 can be used with these issues. Pelican T400 Controllers must include Configuration and Conf...
Page 13 - Safety Warning
Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 13 3.3 C ONFIGURING T HE I NTEGRAL F ACILITIES PCB Figure 1 below shows the layout of the Integral Facilities PCB. The position of the links, switches, fuses, connectors and status LED’s is shown. 50mA QB PL1Controller...
Page 15 - Figure 3 – Lithium Battery Switch Setting; Figure 4 – Last Gasp Dial Battery Switch
Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 15 Note: Due to the position of the switch on the PCB, it is very difficult to turn this switch on after the board has been installed. S2 OFF Battery ON Battery OFF Figure 3 – Lithium Battery Switch Setting Last Gasp D...
Page 17 - Figure 5 – Overview of Components; (See overleaf for the TfL TCUG Outercases)
Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 17 3.7 C ONNECTING T HE IMU When the modem (as required), battery and Integral Facilities Processor have been installed into the Controller the following connections must be made: • Section 3.7.1: Extended System Bus C...
Page 18 - TfL TCUG SMALL OUTERCASE; Figure 5 – Overview of Components (Continued)
Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 18 TfL TCUG SMALL OUTERCASE T400 PELICAN BT Socket Voltage Transformer Modem LGD Battery PCBs TfL TCUG LARGE OUTERCASE T400 INTERSECTION (THE LARGE AND SMALL TfL TCUG OUTERCASES ARE NOT SHOWN TO SCALE) Current Transfor...
Page 19 - Figure 6 – IMU Connector PL5
Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 19 3.7.1 E XTENDED S YSTEM B US The Extended System Bus is a ribbon cable that links all the logic PCBs of the controller together. This should be plugged into PL1 (see Figure 1 on page 13) and the latches closed. 3.7....
Page 20 - UTC; TO MODEM
Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 20 3.7.3 RS232 C ABLE (N OT UTC C ONTROLLERS ) TO MODEM The RS232 Cable to the modem is a single moulded cable (part number 667/7/25175/000). The RS232 Cable connects the Integral Facilities Processor PCB to the modem....
Page 21 - TO GEMINI BUS PROCESSOR
Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 21 TO GEMINI BUS PROCESSOR The RS232 connection to the GEMINI Bus Processor is a pair of cables. The first is the single moulded cable (part number 667/7/25175/000) used for connection to a modem. The second is a short...
Page 22 - should be checked, as this battery is; not; required and should be removed.
Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 22 3.7.4 M ODEM T ELEPHONE C ONNECTION (N OT UTC C ONTROLLERS ) The Telephone cable supplied with the modem should be connected from the modem to the BT Socket in the controller outercase. In controllers in TfL TCUG Ou...
Page 23 - Current Transformers and Voltage Monitor Connections (T400 Only)
Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 23 If the battery is removed in ‘TC-8 Mode’ the crimps on the Power and Local I/O Cable should be neatly insulated and tied back. 3.7.7 L AMP M ONITORING I NPUTS (T400 O NLY ) The LMU Inputs connect to PL2 (see Figure ...
Page 27 - Connection to the IMU can be achieved by entering “IMU
Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 27 4.3 C ONFIGURE T HE IMU 4.3.1 C ONNECT THE M AINTENANCE T ERMINAL TO THE C ONTROLLER H ANDSET P ORT On a T400 the Terminal should display the prompt automatically when the handset is connected. Initially connection ...
Page 28 - Entering ‘CON
Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 28 (also see section 6.2 on page 35) need to be entered to initiate that mode of operation: Use KME to get level 2 access and then enter “TCE=88” to enable the facility. At this point the IMU will ‘reboot’ into ‘TC8 mo...
Page 31 - Modem
Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 31 5. MAINTENANCE 5.1 S TATUS LED’ S LED’s are included on the front edge of the PCB to provide basic status information. The position of these LED’s and their functions are detailed below… The Power LED should be on, ...
Page 37 - KEV See section 6.4) Lamp Supply Monitoring Commands on page 36.
Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 37 6.5 L AMP M ONITORING C OMMANDS – M AINTENANCE KAC KAC {1-23} {0-1} : integer Displays ADC current and volts (in ADC counts) for each sensor, e.g. KAC 3 0:50 ( ≈ 200mA ≈ 50W) KAC 3 1:732 ( ≈ 240V). The handset comma...
Page 43 - FLC; FLH; Entering the command with no index displays the most; FLC n
Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 43 6.8.5 F AULT L OG C OMMANDS (FLC AND FLH) The current fault log contains entries for currently active faults (and those events not yet reported to the instation). If the IMU is running firmware PB580 in TC8 mode, ev...
Page 45 - The phase on which the colour has failed (Phases A to P)
Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 45 6.9 F AULT D ISPLAY C ODES AND T EXT This section contains all the fault log codes and associated text, as seen when using the FLC and FLH commands. The variable values used in the reports are explained below: level...