Page 2 - English; Contents; Safety Information
2 English Contents For information on Samsung’s environmental commitments and product specific regulatory obligations e.g. REACH visit: samsung.com/uk/aboutsamsung/samsungelectronics/corporatecitizenship/data_corner.html Safety Information 3 General information 3 Installing the unit 4 Power supply l...
Page 3 - General information; WARNING
3 English Sa fe ty In fo rm at io n WARNING • Hazards or unsafe practices that may result in severe personal injury or death. CAUTION • Hazards or unsafe practices that may result in minor personal injury or property damage. Carefully follow the precautions listed below because they are essential to...
Page 4 - Installing the unit; Power supply line, fuse or circuit breaker
4 Safety Information English Sa fe ty In fo rm at io n • For use in Europe: This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction conc...
Page 5 - Installation Procedure; Step 1 Choosing the installation location; Installation location requirements; CAUTION
5 English Installation Pr oc edur e Installation Procedure Step 1 Choosing the installation location Installation location requirements • Do not place the outdoor unit on its side or upside down. Failing to do so may cause the compressor lubrication oil to run into the cooling circuit and lead to a ...
Page 6 - Installation Pr; • Install the unit in a place where water can drain; Minimum clearances for the outdoor unit; • The outdoor unit must be installed according to the
6 Installation Procedure English Installation Pr oc edur e • Install the unit in a place where water can drain smoothly. • If you have any difficulty finding installation location as prescribed above, contact your manufacturer for details. • Be sure to clean the sea water and the dust on the heat ex...
Page 7 - Step 2 Checking and preparing; Step 3 Fixing the outdoor unit in place; NOTE
7 English Installation Pr oc edur e Step 2 Checking and preparing accessories and tools 3-wire Power Cable (option) 2-wire Assembly Cable (option) Drain Plug Energy Label Rubber Leg Installation Manual Flare Nuts, 15.88mm outer pipe diameter Flare Nuts, 9.52mm outer pipe diameter Tube connector (Pip...
Page 8 - Step 4 Connecting the power cables,
8 Installation Procedure English Installation Pr oc edur e Optional: Fixing the outdoor unit to a wall with a rack Soft rubber designed to cut off vibration from rack to wall. (not supplied with product) Designed to cut off residual vibration from outdoor unit to rack. (not supplied with product) An...
Page 9 - Conncting the cables to the outdoor unit; Specification for circuit breaker and power supply cord
9 English Installation Pr oc edur e Conncting the cables to the outdoor unit Specification for circuit breaker and power supply cord • Power supply cord is not supplied with air conditioner. • Select the power supply cord in accordance with relevant local and national regulations. • Wire size must c...
Page 10 - • Use rated cables only.; Tightening power terminal
10 Installation Procedure English Installation Pr oc edur e • Connect the cables to the terminal board using the compressed ring terminal. • Use rated cables only. • Connect the cables with driver and wrench that can apply the rated torque to the screws. • Make sure that appropriate tightening torqu...
Page 13 - Step 5 Optional: Extending the power; Method 2
13 English Installation Pr oc edur e Outdoor-to-indoor power and communication cables specifications Indoor power supply Power supply Max/Min (V) Indoor power cable ߣףࡥߤߤߢࣛߤߦߢǤࡥߧߢ²і ±10% 1.5 mm² ८ , 3 wires Communication cable 0.75 to 1.5 mm², 2 wires • Power supply cords of parts of appliances for ...
Page 15 - Step 6 Connecting the refrigerant pipe; ॳâߣߢߢđAâߧk2; ƊϩʪΧߩĮΧϩ̈ͱ͝ɇ̷ࡤAЇϩϩ̈͝ ̋ɇ͝ʒѤɇθ̈͝ ̋
15 English Installation Pr oc edur e Step 6 Connecting the refrigerant pipe ॳâߣߢߢđAâߧk² 1 Piping outside diameter. Indoor unit Out unit Power supply Ø, V, Hz Outside diameter Liquid Gas ७७ߢߤߢࢩߢߤߨࢩ ߢߥߧࢩߢߩࢩߢ߫ࢩߣߤ७७ AJ100MCJ5EH 1,220-240, 50/60 1/4” 3/8” ७७ߢߧߤࢩߣߪ७७ 1/2” ७७ߤߦ७७ 5/8” A B (h) (H) C D Main ...
Page 16 - Step 8 Connecting up and removing air
16 Installation Procedure English Installation Pr oc edur e 5 Check that the flaring is correct, referring to the illustrations below for examples of incorrect flaring. 3 2 1 Correct Inclined Damaged Surface Cracked Uneven Thickness CAUTION • If the pipes require brazing ensure that OFN(Oxygen Free ...
Page 17 - Step 9 Performing the gas leak test; økçƟkƊƟǮÃƟ2ĘÃƟŵĮkĘ࣑ɵʪ ̇ͱθʪͱΧʪ̈͝͝ ̋Эɇ̷Эʪθ࣒; Vacuum; âߣߢߢđAâߧk2; Valve stem
17 English Installation Pr oc edur e 3 Open the valve of the low pressure side of manifold gauge counter clockwise. 4 Purge the air from the system using vacuum pump for about 30 minutes. • Close the valve of the low pressure side of manifold gauge clockwise. • Make sure that pressure gauge show -0....
Page 18 - Important information regulation regarding the; Calculating the quantity of refrigerant to add
18 Installation Procedure English Installation Pr oc edur e Step 10 Adding refrigent (R-410A) Important information regulation regarding the refrigerant used This product contains fluorinated greenhouse gases. Do not vent gases into the atmosphere. CAUTION • Inform user if system contains 5 tCO 2 e ...
Page 19 - Step 11 Connecting the drain hose to
19 English Installation Pr oc edur e Cylinder with siphon Cylinder without siphon siphon Charge the refrigerant standing the cylinder upright. Charge the refrigerant turning the cylinder upside down. NOTE • If R410A refrigerant is charged with gas, the composition of the charged refrigerant changes ...
Page 20 - Step 13 Setting an indoor unit address; • This product is prohibited one indoor unit installation.; • If the LED indications of the part B are different
20 Installation Procedure English Installation Pr oc edur e Step 13 Setting an indoor unit address and installation option Setting the indoor unit address and inspecting the pipes automatically CAUTION • This product is prohibited one indoor unit installation. Don't use pipe checking operation and a...
Page 21 - Installing an additional indoor unit after installation; Setting the indoor unit addresses manually; Press the K3 button once or reset the outdoor unit.
21 English Installation Pr oc edur e Installing an additional indoor unit after installation 1 After installing the indoor unit while the outdoor unit is turned off, turn on the outdoor unit, and check if the LED indications change as shown in the following table: A B RED GRN RED GRN YEL 2 Press the...
Page 22 - ࣑ߢ॔ࢨߣ॔9ࢨߤ॔Aࢨߥ॔Uࢨߦ॔k࣒; Setting Option
22 Installation Procedure English Installation Pr oc edur e ŵĮƟŵǽƊǮÃƟA²࣬ƊǮߢߤ࣭ťĮƊÃƟÃĮĘAAĮŵUÃĘƟĮŵkŵÃkŵĘƟAÃŵAƸÃƟAĮĘĘkAƟkU ࣑ߢ॔ࢨߣ॔9ࢨߤ॔Aࢨߥ॔Uࢨߦ॔k࣒ OUTDOOR UNIT A unit B unitC unit D unit E unit Indoor Unit SW02 0 Att. "A" 1 Att. "B" 2 Att. "C" 3 Att. "D" 4 Att. "E"...
Page 23 - The procedure of setting option
23 English Installation Pr oc edur e 3 Each time you press Low Fan button, 7-seg on left side is increased by “1” and each time you press High Fan button, 7-seg on right side is increased by “1” 4 You press button to move to the next setting page. 5 After setting option, press button to check whethe...
Page 25 - Check whether power is supplied or not.; Assign an indoor unit address by wireless remote controller.
25 English Installation Pr oc edur e Setting an indoor unit address (MAIN/RMC) 1 Check whether power is supplied or not. ࣞ When the indoor unit is not plugged in, there should be additional power supply in the indoor unit. Indoor Unit 1(L) 2(N) F2F1 2 The panel(display ) should be connected to an in...
Page 27 - Ɗʪϩϩ̈͝ ̋ϩͱAͱͱ̷ͱθ2ʪɇϩͱ̷͝ц͔ͱʒʪ; Cool
27 English Installation Pr oc edur e Ɗʪϩϩ̈͝˝ϩͱAͱͱ̷ͱθ²ʪɇϩͱ̷͝ц͔ͱʒʪ This function enables the indoor units connected to the outdoor unit to operate in a specific mode. â७७७đAâ७k² Set the indoor mode Switch Switch Selection 3 4 Cooling and Heating OFF OFF ON ON Only Cooling ON OFF Only Heating OFF ON St...
Page 28 - edur; Extra Procedures; Pumping down refrigerant; Relocating the indoor and outdoor units; Pumping down
28 Extra Procedures English Extra Proc edur es Extra Procedures Pumping down refrigerant WARNING • After installing the product, be sure to perform leak tests on the piping connections. After pumping down refrigerant to inspect or relocate the outdoor unit, be sure to stop the compressor and then re...
Page 29 - Using the stop valve; Opening the stop valve; Closing the stop valve
29 English Extra Proc edur es Using the stop valve Opening the stop valve 1 Open the cap and turn the stop valve anticlockwise by using a hexagonal wrench. 2 Turn it until the axis is stopped. Tightening torque for charging port cap (Refer to the table) Charging core Tightening torque for body cap (...
Page 30 - ppendix; Troubleshooting; Appendix
30 English A ppendix Troubleshooting The table below list the self-diagnostic routines. For some of error, you must contact an authorized service center.If an error occurs during the operation, it is displayed on the outdoor unit HUB PCB. ࣞ The error codes in the list are for reference only. They ar...