Page 2 - Contents; Safety Information
2 English Contents Safety Information 3 General information 3 Installing the unit 4 Power supply line, fuse or circuit breaker 4 Installation Procedure 5 Step 1 Choosing the installation location 5 Step 2 Fixing the outdoor unit in place 8 Step 3 Connecting the power cables, communication cable, and...
Page 3 - English; Saf; General information; WARNING
3 English Saf e ty Inf ormation Safety Information WARNING • Hazards or unsafe practices that may result in severe personal injury or death. CAUTION • Hazards or unsafe practices that may result in minor personal injury or property damage. Carefully follow the precautions listed below because they a...
Page 4 - Installing the unit
4 Safety Information English Saf e ty Inf ormation • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the applian...
Page 5 - Installation Procedure; Installation location requirements; CAUTION
5 English Installation Pr ocedur e Installation Procedure Step 1 Choosing the installation location Installation location requirements • Do not place the outdoor unit on its side or upside down. Failing to do so may cause the compressor lubrication oil to run into the cooling circuit and lead to a s...
Page 6 - • Depending on the condition of power supply, unstable; Outdoor unit dimensions; A Type; Minimum clearances for the outdoor unit; When installing 1 outdoor unit; When installing more than 1 outdoor unit
6 Installation Procedure English Installation Pr ocedur e CAUTION • Depending on the condition of power supply, unstable power or voltage may cause malfunction of the parts or control system. (At the ship or places using power supply from electric generator...etc) • Install the unit in a place where...
Page 7 - Moving the outdoor unit with wire rope
7 English Installation Pr ocedur e 300 or more 600 or more 600 or more 600 or more 300 or mor e 300 or more 300 or more 500 or mor e 500 or mor e CAUTION • The outdoor unit must be installed according to the specified distances in order to permit accessibility from each side, to guarantee correct op...
Page 8 - Step 2 Fixing the outdoor unit in place
8 Installation Procedure English Installation Pr ocedur e Step 2 Fixing the outdoor unit in place Install the outdoor unit on a rigid and stable base to prevent disturbance from any noise caused by vibration. When installing the unit at a height or in a location exposed to strong winds, fix the unit...
Page 9 - NOTE; Air conditioning system examples
9 English Installation Pr ocedur e Step 3 Connecting the power cables, communication cable, and controllers You must connect the following three electrical cables to the outdoor unit: • The main power cable between the auxiliary circuit breaker and the outdoor unit. • The outdoor-to-indoor power cab...
Page 10 - When using ELB for 1 phase and 3 phase; • The unbalanced power must be maintained within 2% of supply rating.
10 Installation Procedure English Installation Pr ocedur e Connecting the main power cable When using ELB for 1 phase and 3 phase 1(L) 2(N) L1(R) L2(S) L3(T) N F1 F2 1(L) 2(N) L N F1 F2 MCCB ELB Power supply Electrical component box The appearance of the unit may be different from the picture depend...
Page 11 - Main power terminal block specifications
11 English Installation Pr ocedur e Main power terminal block specifications • 1-phase terminal block specifications AC090/100/120/140MXADKH, AC120MXASEH 1(L) 2(N) F1 F2 L N 15 12 11.4 10.1 • 3-phase terminal block specifications AC090/100/120/140MXADNH 1(L) 2(N) L1(R) L2(S) L3(T) N 9.95 11.55 10.1 ...
Page 15 - Indoor power supply
15 English Installation Pr ocedur e Outdoor-to-indoor power and communication cables specifications Indoor power supply Power supply Max/Min (V) Indoor power cable 1ø, 220-240V, 50 Hz ±10% 1.5 mm² Ĺ , 3 wires Communication cable 0.75 to 1.5 mm², 2 wires • Power supply cords of parts of appliances fo...
Page 16 - Method 1
16 Installation Procedure English Installation Pr ocedur e 3 Insert both sides of core wire of the power cable into the connection sleeve. • Method 1 : Push the core wire into the sleeve from both sides. • Method 2 : Twist the wire cores together and push it into the sleeve. Connection sleeve Connec...
Page 17 - Step 5 Connecting the refrigerant pipe; Items
17 English Installation Pr ocedur e Step 5 Connecting the refrigerant pipe Items Maximum allowable length Single installation DPM installation Applicable outdoor unit models AC090MXAD*H AC100MXAD*H AC120MXAD*H AC120MXAS*H AC140MXAD*H AC100MXAD*H AC120MXAD*H AC140MXAD*H Total pipe length (L 1 +…+L n+...
Page 19 - Step 7 Installing oil traps
19 English Installation Pr ocedur e Step 7 Installing oil traps Check the following list and install an oil trap. • Based on cooling operation, install it on the gas side pipe only. • Install the oil trap only in between the outdoor unit and the first branch joint and it should be installed at every...
Page 20 - Calculating the quantity of refrigerant to
20 Installation Procedure English Installation Pr ocedur e 3 Connect the charging hose of low pressure side of manifold gauge to the packed valve having a service port as shown at the figure. CAUTION • The designs and shape are subject to change according to the model. 4 Open the valve of the low pr...
Page 21 - Calculating the quantity of refrigerant to add; Single installation outdoor unit
21 English Installation Pr ocedur e Important information: regulation regarding the refrigerant used This product contains fluorinated greenhouse gases. Do not vent gases into the atmosphere. CAUTION • Inform user if the system contains 5 tCO 2 e or more of fluorinated greenhouse gases. In this case...
Page 23 - Instruction for installation and operation; Step 10 Performing the gas leak test; LEAK TEST WITH NITROGEN (before opening valves)
23 English Installation Pr ocedur e Instruction for installation and operation • You should install the DPM according to the above installation specification and eliminate the factors that give electrical load to the both indoor units when installing and operating. (Heater / window / front door / ve...
Page 25 - Step 13 Checking the earthing
25 English Installation Pr ocedur e Pipe Pipe size (mm) Insulation Type (Heating/Cooling) Remarks Standard [Less than 30°C, 85%] High humidity [over 30°C, 85%] EPDM, NBR Liquid pipe Ø6.35~Ø9.52 9 t 9 t Internal temperature is higher than 120°C Ø12.7~Ø19.05 13 t 13 t Gas pipe Ø6.35 13 t 19 t Ø9.52~Ø1...
Page 29 - Extr; Extra Procedures; Pumping down refrigerant; Pumping down
29 English Extr a Pr ocedur es Extra Procedures Pumping down refrigerant WARNING • After installing the product, be sure to perform leak tests on the piping connections. After pumping down refrigerant to inspect or relocate the outdoor unit, be sure to stop the compressor and then remove the connect...
Page 30 - Using the stop valve; Opening the stop valve; Closing the stop valve
30 Extra Procedures English Extr a Pr ocedur es Using the stop valve Opening the stop valve 1 Open the cap and turn the stop valve anticlockwise by using a hexagonal wrench. 2 Turn it until the axis is stopped. Tightening torque for charging port cap(Refer to the table) Charging Core Spindle Tighten...
Page 31 - Appendix; Troubleshooting
31 English Appendix Appendix Troubleshooting The table below list the self-diagnostic routines. For some of error codes, you must contact an authorized service centre. If an error occurs during the operation, it is displayed on the outdoor unit PCB LED, both MAIN PCB and INVERTER PCB. No. Error Code...
Page 32 - Technical specifications
32 Appendix English Appendix No. Error Code Meaning Remarks 22 E441 Cooling operation restricted at outdoor temperature below Tcool_low value (default:0°C) 1. Check the range of temperature limited for cooling operation 2. Check the outdoor temperature sensor 23 E458 Fan speed error FAN1 ERROR 24 E4...
Page 33 - PRODUCT FICHE (ENERGY LABELLING OF AIR CONDITIONERS)
33 English Appendix COMMISSION DELEGATED REGULATION (EU) No 626/2011 i) PRODUCT FICHE (ENERGY LABELLING OF AIR CONDITIONERS) ii) A Supplier's name - Samsung Electronics Co.. Ltd. B Model name (Indoor/Outdoor) - AC090MN4DKH / AC090MXADKH AC090NN4DKH / AC090MXADKH AC090MNMDKH / AC090MXADKH AC090MN4PKH...
Page 44 - , sur une période de 100 ans. Ne tentez jamais d’intervenir dans
44 Appendix English Appendix [ESPAÑOL-ES] 1 Las fugas de refrigerante contribuyen al cambio climático. Cuanto mayor sea el potencial de calentamiento global (GWP) de un refrigerante, más contribuirá a dicho calentamiento su vertido a la atmósfera. Este aparato contiene un líquido refrigerante con un...
Page 45 - stets Fachpersonal hinzuziehen.
45 English Appendix [DEUTSCH-DE] 1 Der Austritt von Kältemittel trägt zum Klimawandel bei. Kältemittel mit geringerem Treibhauspotenzial tragen im Fall eines Austretens weniger zur Erderwärmung bei als solche mit höherem Treibhauspotenzial. Dieses Gerät enthält Kältemittel mit einem Treibhauspotenzi...
Page 46 - szivárgott volna a légkörbe. Soha ne próbálja
46 Appendix English Appendix [MAGYAR-HU] 1 A hűtőközeg-szivárgás fokozza az éghajlatváltozást. Az alacsonyabb globális felmelegedési potenciállal (GWP) rendelkező hűtőközegek kevésbé járulnak hozzá a globális felmelegedéshez, ha a légkörbe jutnak, mint a magasabb együtthatójú típusok. A berendezés [...
Page 47 - ɡɚɩɟɪɢɨɞɨɬɝɨɞɢɧɢɇɢɤɨɝɚɧɟɫɟɨɩɢɬɜɚɣɬɟɫɚɦɢɞɚ
47 English Appendix [ ȻɔɅȽȺɊɋɄɂ%*@ 1 Ɍɟɱɨɜɟɬɟɧɚɯɥɚɞɢɥɟɧɚɝɟɧɬɞɨɩɪɢɧɚɫɹɬɡɚɢɡɦɟɧɟɧɢɟɬɨɧɚɤɥɢɦɚɬɚɏɥɚɞɢɥɟɧɚɝɟɧɬɫɩɨɧɢɫɴɤɩɨɬɟɧɰɢɚɥɡɚɝɥɨɛɚɥɧɨɡɚɬɨɩɥɹɧɟ*:3ɛɢɞɨɩɪɢɧɟɫɴɥɩɨɦɚɥɤɨɡɚɝɥɨɛɚɥɧɨɬɨɡɚɬɨɩɥɹɧɟɨɬɤɨɥɤɨɬɨɯɥɚɞɢɥɟɧɚɝɟɧɬɫɩɨɜɢɫɨɤ*:3ɜɫɥɭɱɚɣɧɚɢɡɬɢɱɚɧɟɜɚɬɦɨɫɮɟɪɚɬɚɌɨɡɢɭɪɟɞɫɴɞɴɪɠɚɬɟɱɟɧɯɥɚɞɢɥɟɧɚɝɟɧɬɫ*:3ɪɚɜɟɧɧɚ>@Ɍɨɜɚɨ...
Page 48 - under en period om 100 år. Försök aldrig att göra
48 Appendix English Appendix [SVENSKA-SV] 1 Läckande köldmedium bidrar till klimatförändringen. Köldmedier med lägre global uppvärmningspotential (GWP) bidrar mindre till den globala uppvärmningen än köldmedier med högre GWP-värde, om de skulle läcka ut i atmosfären. Den här enheten innehåller ett k...
Page 49 - . Nekādā gadījumā nemēģiniet iejaukties
49 English Appendix [LATVIEŠU-LV] 1 Aukstumaģenta noplūde veicina klimata pārmaiņas. Aukstumaģents ar zemāku globālās sasilšanas potenciālu (GWP) globālo sasilšanu veicina mazākā mērā nekā aukstumaģents ar augstāku GWP, ja notiek noplūde atmosfērā. Šajā iekārtā izmantots aukstumaģenta šķidrums, kura...
Page 50 - Memo
Page 52 - Samsung Electronics
SAMSUNG ELECTR ONICS CO., LTD . 107, Hanamsandan 6beon-ro, Gwangsan-gu, Gwangju-si, Korea 62218 Samsung Electronics Service Department PO Box 12987, Blackrock, Co. Dublin. Ireland or Blackbushe Business Park, Yateley, GU46 6GG. UK