Framing and Finishing 1) Determine the total thickness of facing material (e.g. drywall plus ceramic tiles) to allow the fi nished surface to be fl ush with the front of the unit. Total facing thickness can vary from 1/2” (13mm) to 1-¼” (32mm) thick. 2) Frame in the enclosure for the unit with framing...
Regency Direct Vent System (Flex) Horizontal Terminations Only These venting systems, in combination with the P121/P131 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by Warnock Hersey. The location of the termination cap must conform to the requirements in the...
Rigid Pipe Adapter 1-1/2”(38mm) 45 Elbow o Venting Arrangements - Ver tical Ter minations Rigid Pipe System (Propane & Natural Gas) The P121 /131 is approved for a maximum 35 ft. straight vertical, with Rigid Pipe vent systems for Propane and Natural Gas. • Vent must be supported at offsets. • H...