Regency P121/P131-NG2 - Manual

Regency P121/P131-NG2

Regency P121/P131-NG2 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
Page: / 7

Table of Contents:

  • Page 2 – Framing and Finishing; Frame in the enclosure for the unit with framing material.; Combustible Mantels; Combustible mantel clearances from top of; Parallel Wall Clearances; Min distance from glass to a parallel wall; WARNING; Clearance Requirements; Gas Fireplaces
  • Page 3 – AstroCap; Snorkel Ter minations; Snorkel Terminations:; Alternate Horizontal; June 2007 Regency Product Specifi cations Book
  • Page 4 – Rigid Pipe System; The P121 /131 is approved for a maximum 35 ft. straight vertical, with; Maximum; Two 45° elbows = One 90° elbow; Option; IMPORTANT; When installing this unit vertically, the 45 ̊; Rigid Pipe Venting
  • Page 6 – Venting Arrangements - Horizontal; This diagram shows allowable venting confi gurations; Note: FPI Direct Vent System (Flex) is only approved for horizontal
Loading the manual

P121 - P121LC/RC - P131 Zero Clearance Direct Vent Gas Fireplace

Model

P121/P131-NG2

P121/P131-LP2

Fuel Type

Natural Gas

Propane

Minimum Supply Pressure

5” W.C. (1.25 kPa)

12” W.C. (3.00 kPa)

Manifold Pressure - High

3.8” W.C. (0.95 kPa)

11” W.C. (2.74 kPa)

Manifold Pressure - Low

1.1” W.C. (0.27 kPa)

2.9” W.C. (0.72 kPa)

Orifi ce Size

#31 DMS

#50 DMS

Minimum Input

20,500 BTU/h (6.01 kW)

20,600 BTU/h (6.04 kW)

Maximum Input

40,000 BTU/h (11.72 kW)

39,000 BTU/h (11.43 kW)

Vent Sizing

4” Inner / 6-5/8” Outer

4” Inner / 6-5/8” Outer

P

Gas Line

Inlet

Electrical

Inlet

BACK

N

O

M

A

D

C

G

E

B

F

P121 See Thru

P131 Pier

P121RC Right Corner

P121LC Left Corner

Unit Dimensions

Description

P121

P121LC/RC

P131

A

Front Face Width

43-1/2”

(1105mm)

41-1/2”

(1054mm)

41-1/2”

(1054mm)

B

Total Firebox Width

46-1/4”

(1175mm)

44-1/2”

(1130mm)

44-1/2”

(1130mm)

C

Front Face Height

36” (914mm)

36” (914mm)

36” (914mm)

D

Height w/ Standoff

42” (1067mm)

42” (1067mm)

42” (1067mm)

E

Unit Depth

25” (635mm)

26-13/16”

(681mm)

25” (635mm)

F

Top Offset Depth

21-1/8”

(537mm)

21-1/8”

(537mm)

21-1/8”

(537mm)

G

Inset to Standoff

4-3/4”

(121mm)

4-3/4”

(121mm)

3” (76mm)

H

I

J

K

Combustible

Material

3”

Extension

Trim

Non-Combustible

Material *

Top of

Unit

8”

Greyed out framing will not apply to all units.

Please refer to the manual.

L

Framing Dimensions Description

P121

P121LC/RC

P131

H

Framing Width

46-3/4”

(1187mm)

45”

(1143mm)

**

45”

(1143mm)

**

I

**

Framing Height

**

42-1/2”

(1080mm)

42-1/2”

(1080mm)

42-1/2”

(1080mm)

J

**

Framing Depth

**

25” (635mm)

**

26-13/16”

(681mm)

25” (635mm)

**

K

Vent Centerline Height

42-13/16” (1072mm)

L

Framed Chase Ceiling

48-1/4” (1226mm)

M

Electrical Inlet Height

2” (51mm)

2” (51mm)

2” (51mm)

N

Electrical Inlet Inset

11-3/8”

(289mm)

13-5/16”

(338mm)

11-3/8”

(289mm)

O

Gas Connection Height

1-11/16”

(43mm)

1-11/16”

(43mm)

1-5/8” (41mm)

P

Gas Connection Inset

11-1/2”

(292mm)

11-1/2”

(292mm)

11-1/2”

(292mm)

**

Refer to the manual for variations effected by fi nishing material

thickness.

P121-P131 Gas Fireplace

If the provided 3” extension trim is not installed the P121(LC/RC)/
P131 must be installed with non-combustible facing up to 8” above
the fi replace. Otherwise combustible facing may be used above the
extension trim.

Approved Venting Systems

Flex Vent Systems:

FPI AstroCap™ Flex Vent

Rigid Pipe Vent Systems:

Simpson Dura-Vent® Direct Vent GS
American Metal Products Ameri Vent
Security Secure Vent®
Selkirk Direct-Temp.

Please refer to Page 11 (Exterior Vent Terminations)

for additional guidelines on vent locations.

69

June 2007 Regency Product Specifi cations Book

Gas Fireplaces

Gas Fir

eplaces

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Framing and Finishing; Frame in the enclosure for the unit with framing material.; Combustible Mantels; Combustible mantel clearances from top of; Parallel Wall Clearances; Min distance from glass to a parallel wall; WARNING; Clearance Requirements; Gas Fireplaces

Framing and Finishing 1) Determine the total thickness of facing material (e.g. drywall plus ceramic tiles) to allow the fi nished surface to be fl ush with the front of the unit. Total facing thickness can vary from 1/2” (13mm) to 1-¼” (32mm) thick. 2) Frame in the enclosure for the unit with framing...

Page 3 - AstroCap; Snorkel Ter minations; Snorkel Terminations:; Alternate Horizontal; June 2007 Regency Product Specifi cations Book

Regency Direct Vent System (Flex) Horizontal Terminations Only These venting systems, in combination with the P121/P131 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by Warnock Hersey. The location of the termination cap must conform to the requirements in the...

Page 4 - Rigid Pipe System; The P121 /131 is approved for a maximum 35 ft. straight vertical, with; Maximum; Two 45° elbows = One 90° elbow; Option; IMPORTANT; When installing this unit vertically, the 45 ̊; Rigid Pipe Venting

Rigid Pipe Adapter 1-1/2”(38mm) 45 Elbow o Venting Arrangements - Ver tical Ter minations Rigid Pipe System (Propane & Natural Gas) The P121 /131 is approved for a maximum 35 ft. straight vertical, with Rigid Pipe vent systems for Propane and Natural Gas. • Vent must be supported at offsets. • H...