Page 2 - REGENCY; TO THE NEW OWNER
2 Regency I31-3 Gas Fireplace Inbuilt REGENCY GAS FIREPLACE INBUILT FIREPLACE TO THE NEW OWNER Congratulations! You are the owner of a state-of-the-art Gas Inbuilt Fireplace by RegencyIndustries. The Regency Gas Fireplace Series of hand crafted appliances has been designedto provide you with all the...
Page 3 - TABLE OF CONTENTS; REGENCY GAS FIREPLACE INSERT; Operating Instructions; Parts List; Warranty; Installation; Page
3 Regency I31-3 Gas Fireplace Inbuilt TABLE OF CONTENTS REGENCY GAS FIREPLACE INSERT Operating Instructions Operating Instructions ................................................ 16Lighting Procedure ...................................................... 16Shutdown Procedure ..........................
Page 4 - DATA BADGE
4 Regency I31-3 Gas Fireplace Inbuilt DATA BADGE (Australia Only) This is a copy of the label that accompanieseach Regency I31-3 Gas Inbuilt fireplace. Wehave printed a copy of the contents here foryour review. DATA BADGE NOTE: Regency units are con- stantly being improved. Check the label on theuni...
Page 5 - INSTALLATION
5 Regency I31-3 Gas Fireplace Inbuilt INSTALLATION IMPORTANT: SAVE THESE INSTRUCTIONS The Regency Gas Fireplace must be installed inaccordance with these instructions. Carefullyread all the instructions in this manual first. Note: Failure to follow these instructions could cause a malfunction of the...
Page 6 - Mantel Clearances with
6 Regency I31-3 Gas Fireplace Inbuilt GAS CONNECTION 3) Locate the center point where the flue willpass through the chimney above the appli-ance. Move the appliance into the exactlocation where it is to be installed. Ensurethat the Insert is level. 4) The installer must provide a valve with aplugged...
Page 7 - Combustion and Ventilation Air
7 Regency I31-3 Gas Fireplace Inbuilt TEST FOR FLUE SPILLAGE A " spillage" test must be made beforethe installed unit is left with the custom-er. Follow the procedure below: 1) Start all exhaust fans in the home and thenclose all external doors and windows in thehouse. 2) Light the unit and ...
Page 8 - LOG SET; OPTIONAL
8 Regency I31-3 Gas Fireplace Inbuilt LOG SET INSTALLATION Read the instructions below carefully andrefer to the diagrams. If logs are brokendo not use the unit until they are replaced.Broken logs can interfere with the pilotoperation. The gas log kit contains the following: a) 02-43 Rear Log 902-22...
Page 10 - FLUSH FRONT; Ensure that the wires do NOT
10 Regency I31-3 Gas Fireplace Inbuilt FLUSH FRONT INSTALLATION 1) Install Logs before going on to the next step. See the Log Installation instructionsheet or page 8 in the manual. 2) Install the bottom glass trim by hooking the trim into the lip on the firebox base. The trimwill not fit into place ...
Page 11 - FLUSH LOUVRES
11 Regency I31-3 Gas Fireplace Inbuilt BAY FRONT INSTALLATION 1) Place the bay door onto the 2 pins on the topof the unit. 2) Install bottom louvre by sliding the twobracket clips into the brackets located un-derneath the bay door and secure with 2screws into the bracket on the bottom of theBay Fron...
Page 12 - HAMPTON CAST
12 Regency I31-3 Gas Fireplace Inbuilt HAMPTON CAST FACEPLATE INSTALLATION 1) Lay the faceplate panels flat, face down on something soft so theydon't scratch. 2) Attach the side filler brackets to the left and right sides using 3screws and washer per side. 3) Attach the right and left cast sides to ...
Page 14 - BAROSSA CURVED
14 Regency I31-3 Gas Fireplace Inbuilt BAROSSA CURVED FRONT INSTALLATION 1) Install bottom louver by matching the holes in louver bracket with holesin firebox frame and secure using 2 screws on each side. 2) Pull down louver. 3) Fix brackets onto firebox, one on each side using 1 screw per side. 4) ...
Page 15 - OPTIONAL REMOTE; Wire Size; WIRING; OPTIONAL WALL
15 Regency I31-3 Gas Fireplace Inbuilt INSTALLATION Thermostat Wire Table CAUTION Do not connect the millivolt wall thermostat wires to the 240 V wires. Recommended Maximum Lead Length (Two-Wire) When Using Wall Thermostat (CP-2 System) OPTIONAL REMOTE CONTROL Use the Optional Remote Control Kit app...
Page 16 - OPERATING INSTRUCTIONS
16 Regency I31-3 Gas Fireplace Inbuilt OPERATING INSTRUCTIONS 4) Wait five minutes to allow gas, that may haveaccumulated in the main burner compart-ment, to escape. If you do smell gas, followthe instructions on the front of this manual.If you don't smell gas continue on to the nextstep. 5) Turn th...
Page 17 - DO NOT REMOVE THIS INSTRUCTION PLATE
17 Regency I31-3 Gas Fireplace Inbuilt MAINTENANCE INSTRUCTIONS 1) Always turn the gas valve to offbefore cleaning. For relighting, re-fer to lighting instructions. Keep theburner and control compartmentclean by brushing and vacuumingat least once a year.When cleaning the logs, use a cleansoft paint...
Page 18 - MAINTENANCE; WARNING; LOG REPLACEMENT; DOOR GLASS
18 Regency I31-3 Gas Fireplace Inbuilt Top View of pilot flame Correct flame pattern has two strongblue flames: 1 flowing around the ther-mopile and 1 reaching towards the rearburner (it does not have to be touchingthe burner). Top View of pilot flame Incorrect flame pattern will have small,probably...
Page 19 - FAN MAINTENANCE; GLASS GASKET
19 Regency I31-3 Gas Fireplace Inbuilt FAN MAINTENANCE If your fan requires maintenance or replace-ment, access to the fan is through the plate onthe rear wall of the firebox. NOTE: the unit MUST NOT be operated without the fanaccess panel securely in place. CAUTION: Label all wires prior todisconne...
Page 20 - SERVICE SHOULD BE CARRIED OUT BY AUTHORIZED PERSONNEL ONLY; TROUBLE SHOOTING REGENCY GAS SPACE HEATER
20 Regency I31-3 Gas Fireplace Inbuilt SERVICE SHOULD BE CARRIED OUT BY AUTHORIZED PERSONNEL ONLY ABNORMAL OPERATION If main burner does not light but pilot stayson, shut down heater and contact yourdealer. If excessive carbon on logs orglass contact your dealer for service. TROUBLE SHOOTING REGENCY...
Page 21 - PARTS LIST; MAIN ASSEMBLY
21 Regency I31-3 Gas Fireplace Inbuilt PARTS LIST MAIN ASSEMBLY Part # Description Part # Description 1) 400-011 Fan Opening Cover 2) 910-169/P Fan Motor (240 V) 4) 910-714 Power Cord 240 Volts 910-707 Wire Harness (Fan end) 910-771 Wire Harness (Faceplate) 5) 400-068 Thermodisc Cover Mounting Plate...
Page 22 - BURNER ASSEMBLY & LOG SET
22 Regency I31-3 Gas Fireplace Inbuilt BURNER ASSEMBLY & LOG SET Part # Description PARTS LIST 402-565/P Valve Assembly - NG402-566/P Valve Assembly - LPG 52) 910-026 RobertShaw Valve - NG 910-027 RobertShaw Valve - LPG 53) 910-190 Piezo Ignitor and nut 54) * Valve Heat Shield 55) 904-702 Gasket...
Page 23 - FACEPLATE ASSEMBLY
23 Regency I31-3 Gas Fireplace Inbuilt PARTS LIST FACEPLATE ASSEMBLY Part # Description Part # Description 87) 910-140 Fan HI/OFF/LOW Switch 88) 910-246 Burner ON/OFF Switch 403-912 Faceplate & Trim Complete - Regular 91) * Faceplate Side Right - Regular 92) * Faceplate Top - Regular 93) * Facep...
Page 24 - BAY & FLUSH FRONT ASSEMBLY
24 Regency I31-3 Gas Fireplace Inbuilt PARTS LIST BAY & FLUSH FRONT ASSEMBLY Part # Description Part # Description Bay Door 400-988 Complete Bay Front c/w Black Trim 102) * Glass Retainer Side (Top & Btm) 103) * Glass Retainer Front (Top & Btm) 106) 940-315/P Side Glass 107) 936-243 Gask...
Page 25 - HAMPTON CAST FACEPLATE ASSEMBLY
25 Regency I31-3 Gas Fireplace Inbuilt 403-911 Cast Faceplates (Set) - Black Metallic 403-916 Cast Faceplates (Set) - Black Enamel 187) * Burner On/Off Switch 188) * Fan Speed Control 189) * Knob - Black Cast Surround 201) * Cast Faceplate - Right 202) * Cast Faceplate - Top 203) * Cast Faceplate - ...
Page 26 - NOTES
26 Regency I31-3 Gas Fireplace Inbuilt _____________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________...
Page 27 - WARRANTY; Lifetime; Transportation Prepaid
27 Regency I31-3 Gas Fireplace Inbuilt WARRANTY Exclusions: This limited Lifetime Warranty does not extend to or includepaint, door or glass gasketing or trim. It does not coverinstallation and operational related problems such as over-firing, downdrafts or spillage caused by environmental con-ditio...