Page 2 - Rear Flued Room Sealed Freestanding Gas Stove
2 F37 Regency ® Rear Flued Room Sealed Freestanding Gas Heater To the New Owner: Congratulations! You are the owner of a state-of-the-art Regency ® Rear Flued Room Sealed Freestanding Gas Stove by FPI Fireplace Products International. The Regency ® Gas Series of hand crafted appliances has been desi...
Page 3 - TABLE OF CONTENTS
F37 Regency ® Rear Flued Room Sealed Freestanding Gas Heater 3 TABLE OF CONTENTS DATA BADGE Data Badge ................................................................. 4 INSTALLATION Important ..................................................................... 5Specifi cations .......................
Page 4 - DATA BADGE
4 F37 Regency ® Rear Flued Room Sealed Freestanding Gas Heater This is a copy of the label that accompanies each REGENCY Rear Flued Room Sealed Freestanding Gas Stove. We have printed a DATA BADGE copy of the contents here for your review. The data plate is located on the inside of the drop down ped...
Page 5 - IMPORTANT; SAVE THESE; SPECIFICATIONS; INSTALLATION; GENERAL SAFETY
F37 Regency ® Rear Flued Room Sealed Freestanding Gas Heater 5 INSTALLATION AND REPAIRS SHOULD BE DONE BY AN AU-THORIZED SERVICE PERSON. THIS APPLIANCE SHOULD BE I N S TA L L E D , R E PA I R E D , I N -SPECTED BEFORE USE AND AT LEAST ANNUALLY BY AN AUTHORIZED SERVICE PERSON. MORE FREQUENT CLEANING ...
Page 7 - EXTERIOR FLUE TERMINATION LOCATIONS; Minimum clearances required for balanced fl ue terminals or
F37 Regency ® Rear Flued Room Sealed Freestanding Gas Heater 7 INSTALLATION EXTERIOR FLUE TERMINATION LOCATIONS Minimum clearances required for balanced fl ue terminals or the fl ue terminals of outdoor appliances according to AS5601-2004 (AGA gas installation code) or NZS 5261 (New Zealand) Minimum C...
Page 9 - FLUEING ARRANGEMENTS - VERTICAL TERMINATIONS
F37 Regency ® Rear Flued Room Sealed Freestanding Gas Heater 9 INSTALLATION FLUEING ARRANGEMENTS - VERTICAL TERMINATIONS for both Residential & Manufactured Homes/Mobile Homes Offset to Vertical Terminations If connecting to a Dura-Vent system, the Adapter to Dura-Vent # 640-994 is required. Ver...
Page 10 - HORIZONTAL INSTALLATIONS; RESIDENTIAL AND MANUFACTURED HOMES /
10 F37 Regency ® Rear Flued Room Sealed Freestanding Gas Heater INSTALLATION Diagram 2 HORIZONTAL INSTALLATIONS Diagram 1 *Diagram 2: Local codes or regulations may require different clearances. RESIDENTIAL AND MANUFACTURED HOMES / MOBILE HOMES INSTALLATIONS You will require the following components...
Page 12 - GAS CONNECTION; Note: Prior to any pressure testing of; VERTICAL TERMINATION WITH
12 F37 Regency ® Rear Flued Room Sealed Freestanding Gas Heater System Data - F37 Burner Inlet Orifi ce Sizes: NG LPG Burner #37 #52 Max. Input Rating 31.7 mj Min. Input Rating 16 mj Supply Pressure NG min. 1.13kPa LPG min. 2.75kPa Manifold Pressure NG .89 kPa LPG 2.55 kPa GAS CONNECTION The gas conn...
Page 13 - USING SIT 820 NOVA GAS VALVE; Do not over tighten the screw.; Also check that the pilot and main
F37 Regency ® Rear Flued Room Sealed Freestanding Gas Heater 13 INSTALLATION CONVERSION KIT #731-968 FROM NG TO LPG USING SIT 820 NOVA GAS VALVE THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! WARNING! Do not over tighten the screw. Recommended to grip...
Page 14 - AERATION; LOG SET
14 F37 Regency ® Rear Flued Room Sealed Freestanding Gas Heater INSTALLATION C)02-44 AERATION ADJUSTMENT The burner aeration is factory set but may need adjusting due to either the local gas supply, air supply or altitude. NG: 10mm open LPG: 10mm open The aeration adjustment gears are located on the...
Page 15 - DOOR INSTALLATION
F37 Regency ® Rear Flued Room Sealed Freestanding Gas Heater 15 Diagram 2 Diagram 3 4) The latches should already be at the proper setting. If they are too hard or too easy to close, you may want to adjust them by loosening the locking nut and turning the latch catch. See diagram 3. 5) Remove the bl...
Page 16 - CAUTION; Valve Description
16 F37 Regency ® Rear Flued Room Sealed Freestanding Gas Heater INSTALLATION OPTIONAL WALL THERMOSTAT A wall thermostat may be installed if desired. Connect the wires as per the wiring diagrams. Note that the wires are connected to the "TH" on the gas valve. Use table below to determine the ...
Page 17 - FINAL CHECK; OPTIONAL; Thermostat Wire Table; WIRING
F37 Regency ® Rear Flued Room Sealed Freestanding Gas Heater 17 WARNING: Electrical Grounding Instructions This appliance is equipped with a three pronged (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not ...
Page 18 - OPERATING INSTRUCTIONS; DO NOT
18 F37 Regency ® Rear Flued Room Sealed Freestanding Gas Heater OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS 1) Read and understand these instructions before operating this appliance. 2) Check to see that all wiring is correct and enclosed to prevent possible shock. 3) Check to ensure there are no ...
Page 19 - COPY OF THE LIGHTING PLATE INSTRUCTIONS; DO NOT REMOVE THIS INSTRUCTION PLATE
F37 Regency ® Rear Flued Room Sealed Freestanding Gas Heater 19 COPY OF THE LIGHTING PLATE INSTRUCTIONS OPERATING INSTRUCTIONS 1) Push in the gas control knob slightly and turn clockwise to OFF. Do not force. FOR YOUR SAFETY READ BEFORE LIGHTING A ) This appliance has a pilot which must be lighted...
Page 20 - MAINTENANCE
20 F37 Regency ® Rear Flued Room Sealed Freestanding Gas Heater MAINTENANCE PART OF CONTROL SYSTEM AND ANY GAS CONTROL WHICH HAS BEEN UNDER WATER. CAUTION: ANY SAFETY SCREEN OR GUARD REMOVED FOR SERV-ICING AN APPLIANCE MUST BE REPLACED PRIOR TO OPERAT-ING THE APPLIANCE. CLOTHING OR OTHER FLAM-MABLE ...
Page 21 - MITRED DOOR; Installing Glass
F37 Regency ® Rear Flued Room Sealed Freestanding Gas Heater 21 LATCH ADJUSTMENT The door latch may require adjustment as the door gasket material compresses after a few fi res and after glass replacement. Turn the handle on the adjustable catch to tighten or loosen the latch. GLASS REPLACEMENT Your ...
Page 22 - REMOVING VALVE; FAN MAINTENANCE
22 F37 Regency ® Rear Flued Room Sealed Freestanding Gas Heater MAINTENANCE REMOVING VALVE If your valve requires maintenance or replace-ment, use the following instructions: Note: Always close off the gas supply before removing the valve. 1) Open front pedestal door. You may want to put a soft clot...
Page 24 - PARTS LIST; MAIN ASSEMBLY
24 F37 Regency ® Rear Flued Room Sealed Freestanding Gas Heater PARTS LIST 560-921 Louvre Assy (Set) - Nickel 1) 560-920 Louvre Assy (Set) - Gold 560-922 Louvre Assy (Set) - Black 4) 750-532 Door Screen (Australia Only) 8) 730-560 Relief Door Assembly 10) 640-034 Mounting Plate Gasket 560-519/P Fan ...
Page 25 - BURNER & LOG ASSEMBLY
F37 Regency ® Rear Flued Room Sealed Freestanding Gas Heater 25 52 60 68 67 68 66 90 92 95 96 98 97 93 94 91 89 69 71 82 83 54 55 57 78 56 BURNER & LOG ASSEMBLY 52) 910-190 Piezo Ignitor & Nut 54) 910-373 Knob - Pilot Valve Extension 55) 910-372 Flame Adjusting Knob 56) 918-088 Decal - Contr...
Page 26 - DOOR ASSEMBLIES
26 F37 Regency ® Rear Flued Room Sealed Freestanding Gas Heater DOOR ASSEMBLIES Part # Description PARTS LIST 730-923 Brush Nickel Mitred Door - Complete 730-924 Gold Mitred Door - Complete 730-926 Black Mitred Door - Complete 730-932 Gold Wrap Door - Complete 730-928 Gold Panel Door - Complete 101)...
Page 27 - WARRANTY
F37 Regency ® Rear Flued Room Sealed Freestanding Gas Heater 27 WARRANTY Regency ® Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door. FPI is pleased to extend thi...
Page 28 - Printed in Canada
Printed in Canada © Copyright 2006, FPI Fireplace Products International Ltd. All rights reserved.