Page 2 - FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.; The Regency Gas Fireplace Series; has been designed to provide you with all the warmth and charm
2 Regency E21 Gas Fireplace Insert CONGRATULATIONS! You are the owner of a state-of-the-art Gas Insert by: FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. The Regency Gas Fireplace Series has been designed to provide you with all the warmth and charm of a fi replace, at the fl ick of a switch. The models E2...
Page 3 - E21 GAS INSERT; TABLE OF CONTENTS; Combustion & Ventilation Air; Page
3 Regency E21 Gas Fireplace Insert E21 GAS INSERT TABLE OF CONTENTS OPERATING INSTRUCTIONS Operating Instructions .................................................20 Lighting Procedure ......................................................20 Shutdown Procedure ..........................................
Page 4 - SAFETY LABEL
4 Regency E21 Gas Fireplace Insert SAFETY LABEL This is a copy of the label that accompanies each Regency Gas Insert. We have printed a copy of the contents here for your review. The safety label is located on the front inside base of the unit visible when the bottom louver is open. Note: Regency un...
Page 5 - INSTALLATION; GENERAL SAFETY
5 Regency E21 Gas Fireplace Insert IMPORTANT: SAVE THESE INSTRUCTIONS The Regency Gas Fireplace must be installed in accordance with these instructions. Carefully read all the instructions in this manual fi rst. Consult the "authority having jurisdiction" to determine the need for a permit pr...
Page 7 - CLEARANCES TO
7 Regency E21 Gas Fireplace Insert CLEARANCES TO COMBUSTIBLES INSTALLATION The minimum clearance from the side of the appliance to a combustible side wall is 9 inches (229mm). The minimum clearance from the top of the louver to a combustible mantel is 14 inches (356mm) 14 inches (356mm). The minimum...
Page 8 - HIGH ELEVATION; System Data; GAS CONNECTION; Important: Always check for gas leaks
8 Regency E21 Gas Fireplace Insert HIGH ELEVATION This unit is approved in Canada for altitude 0 to 4500 ft. (CAN/CGA 2.17-M91) with the orifi ce supplied. System Data For altitude: Natural Gas 0-2000 ft. Propane: 0-4500 ft. Burner Inlet Orifi ce Sizes: Natural Gas Propane Burner #43 #54 Max. Input Ra...
Page 9 - WIRING DIAGRAM FOR THE E21-NG1 AND E21-LP1; CAUTION: Label all wires prior; Grounding; FLUE CONNECTOR INSTALLATION
9 Regency E21 Gas Fireplace Insert Note: Do not operate unit if fl ue connector is not fastened in original position. WIRING DIAGRAM FOR THE E21-NG1 AND E21-LP1 INSTALLATION CAUTION: Label all wires prior to disconnection when servicing c o n t r o l s . W i r i n g e r r o r s c a n cause improper a...
Page 10 - T H E A P P L I A N C E M U S T N O T B E; WARNING: Operation of this heater
10 Regency E21 Gas Fireplace Insert INSTALLATION GAS PIPE PRESSURE TESTING The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig. (3...
Page 11 - Valve Description
11 Regency E21 Gas Fireplace Insert INSTALLATION TEST FOR FLUE SPILLAGE A " spillage" test must be made before the installed unit is left with the customer. Follow the procedure below: 1) Close all external doors and windows in the house. 2) Light the unit and set controls to maximum. Turn f...
Page 13 - FLUSH GLASS; WARNING; The use of substitute glass will; Do not operate the appliance if the
13 Regency E21 Gas Fireplace Insert Diagram 4 Diagram 5 6) Connect the ON/OFF switch wires by taking the black and red wires with the female ends and connecting them to the ON/OFF switch. FLUSH GLASS 1) Install the bottom glass trim onto the glass support. 2) Slide the glass into the bottom glass tr...
Page 14 - BAY LOUVERS; OPTIONAL BAY FRONT; IMPORTANT; FLUSH LOUVERS
14 Regency E21 Gas Fireplace Insert BAY LOUVERS 1) Install top louver by sliding the two bracket clips into the brackets located on top of the bay door. See below. The fi tted louver leaves a small gap between faceplate bottom and louver top. Diagram 1 NOTE: The top and bottom trim pieces are differe...
Page 17 - FULL SCREEN FRONT
17 Regency E21 Gas Fireplace Insert FULL SCREEN FRONT INSTALLATION 1) Hold the full screen door up against the unit in order to make the following wire connections. Pull the ON/OFF connector wires thru the box and connect them to the switch. Connect the fan switch wires with the wire connectors from...
Page 19 - Thermostat Wire Table; WALL SWITCH; CAUTION; REMOTE CONTROL; CAUTION; WALL THERMOSTAT
19 Regency E21 Gas Fireplace Insert Thermostat Wire Table CAUTION Do not wire millivolt wall thermostat wires to 120V wire. Option 2: WALL SWITCH 1) Run the wire through the right or left side inlet opening. Be careful not to damage the wire. Note: We recommend a maximum of 15' of wire but if you wi...
Page 20 - OPERATING INSTRUCTIONS
20 Regency E21 Gas Fireplace Insert FINAL CHECK Before leaving this unit with the customer, the installer must ensure that the appliance is fi ring correctly. This includes: 1) Clocking the appliance to ensure the correct fi ring rate (rate noted on label) at 15 minutes. 2) If required, adjusting the ...
Page 21 - COPY OF LIGHTING PLATE INSTRUCTIONS
21 Regency E21 Gas Fireplace Insert OPERATING INSTRUCTIONS COPY OF LIGHTING PLATE INSTRUCTIONS LIGHTING INSTRUCTIONS A) This appliance has a pilot which must be lighted byhand. When lighting the pilot, follow these instructionsexactly.B) BEFORE LIGHTING smell all around the appliancearea for gas. Be...
Page 22 - MAINTENANCE
22 Regency E21 Gas Fireplace Insert MAINTENANCE INSTRUCTIONS 1) Always turn the gas valve to off before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year. When cleaning the logs, use a clean soft pai...
Page 23 - REMOVING THE FAN; DOOR GLASS; Bay Glass Removal; Flush Glass Replacement
23 Regency E21 Gas Fireplace Insert REMOVING VALVE ASSEMBLY 1) Disconnect the power. 2) Shut off the gas. 3) Remove top and bottom louvers. 4) Remove top and bottom trim. 5) Remove glass. 6) Remove log set & embers, and brick panels. 7) Disconnect the gas line. 8) Remove wires from valve (top an...
Page 24 - PARTS LIST; MAIN ASSEMBLY
24 Regency E21 Gas Fireplace Insert PARTS LIST MAIN ASSEMBLY Part # Description Part # Description 530-518/P Fan Assembly 1) 910-331/P Fan Motor (120V) 2) 910-750 Power Cord (120V) 910-752 Wire Harness (Intermediate) 3) * Firebox Bottom 4) 936-238 Soft Fiber Gasket 8mm 5) 936-233 3/4" Rope Gaske...
Page 25 - BURNER ASSEMBLY & LOG SET
25 Regency E21 Gas Fireplace Insert BURNER ASSEMBLY & LOG SET Part # Description 533-574/P Valve Assembly- Nat. Gas 533-576/P Valve Assembly - Propane 52) 910-098 Valve SIT - Nat. Gas 910-099 Valve SIT - Propane 53) 910-190 Piezo Ignitor & Nut 56) 910-076 Pilot Assembly - SIT - 3 fl ame -NG 9...
Page 26 - BAY & FLUSH FRONT ASSEMBLY
26 Regency E21 Gas Fireplace Insert PARTS LIST BAY & FLUSH FRONT ASSEMBLY Part # Description Part # Description Bay Door 530-950 Complete Bay Front c/w Black Trim 106) 940-312/P Side Glass 107) 936-243 Gasket - Adhesive Backed 7/8" 108) 940-313/P Center Glass 110) 902-183 Bay Brick Panel - S...
Page 27 - FACEPLATE ASSEMBLY
27 Regency E21 Gas Fireplace Insert FACEPLATE ASSEMBLY Part # Description 91) 910-330 Fan Speed Control (120 V) 92) 904-569 Fan Speed Control Knob 93) 910-246 Burner Switch ON/OFF (2 way) 400-950 Hearth Trim 1" Standard 320-940 Hearth Trim 1" Oversize 400-926 Hearth Trim 2" Standard 320-...
Page 28 - NOTES
28 Regency E21 Gas Fireplace Insert ________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________...
Page 31 - WARRANTY
31 Regency E21 Gas Fireplace Insert WARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility. FPI Fireplace Products International Ltd. is pleased t...
Page 32 - Installer: Please complete the following information; Fireplace Products International
Installer: Please complete the following information Dealer Name & Address: _________________________________________________________________________________________________________________Installer: ___________________________________________________________Phone #: ____________________________...