Page 2 - INDEX; EN
2 2 INDEX RECOMMENDATIONS AND SUGGESTIONS ......................................................................................................................3 CHARACTERISTICS .............................................................................................................................
Page 3 - RECOMMENDATIONS AND SUGGESTIONS; INSTALLATION
EN 3 3 RECOMMENDATIONS AND SUGGESTIONS The Instructions for Use apply to several versions of this appliance. Accord- ingly, you may find descriptions of individual features that do not apply to your specific appliance. INSTALLATION • The manufacturer will not be held liable for any damages resulting...
Page 4 - CHARACTERISTICS; Dimensions
EN 4 4 CHARACTERISTICS Dimensions 650 min. 200 100 ø150 698 - 898 190 240 30 90 55 r 58 492 360 min 560 max 760 Components Ref. Q.ty Product Components 1 1 Hood Body, complete with: Controls, Light, Blower, Filters 2 1 Telescopic Chimney comprising: 2.1 1 Upper Section 2.2 1 Lower Section 8a 1 Right...
Page 5 - Wall drilling and bracket fixing; centre of the area in which the hood will be installed.
EN 5 5 INSTALLATION Wall drilling and bracket fixing Wall marking: • Draw a vertical line on the supporting wall up to the ceiling, or as high as practical, at the centre of the area in which the hood will be installed. • Draw a horizontal line at 650 mm above the hob for installation without the ba...
Page 6 - Mounting the hood body; • Use the adjusting screws 12d underneath the hood to level the; Connections; DUCTED VERSION AIR EXHAUST SYSTEM; • Fix the pipe in position using sufficient pipe clamps (not sup-; RECIRCULATION VERSION AIR OUTLET
EN 6 6 Mounting the hood body • Screw the two screws 12d supplied onto the brackets 7.1. • Hook the hood body onto the bracket 7.1, centring it around the vertical line. • Use the adjusting screws 12d underneath the hood to level the hood body. 12.d 7.1 Connections DUCTED VERSION AIR EXHAUST SYSTEM ...
Page 7 - ELECTRICAL CONNECTION; Chimney assembly
EN 7 7 ELECTRICAL CONNECTION • Connect the hood to the mains through a two-pole switch hav- ing a contact gap of at least 3 mm. • Remove the grease filters (see paragraph Maintenance) being sure that the connector of the feeding cable is correctly inserted in the socket placed on the side of the fan...
Page 8 - USE
EN 8 8 USE 1 1 0 1 0 2 3 L M V L Light Switches the lighting system on and off M Motor Switches the extractor motor on and off V Speed Sets the operating speed of the extractor: 1. Low speed, used for a continuous and silent air change in the presence of light cooking vapour. 2. Medium speed, suitab...
Page 9 - MAINTENANCE; Grease filters; Activated charcoal filter (Recirculation version); REPLACING THE ACTIVATED CHARCOAL FILTER; Lighting; LIGHT REPLACEMENT
EN 9 9 MAINTENANCE Grease filters CLEANING METAL SELF- SUPPORTING GREASE FILTERS • The filters must be cleaned every 2 months of operation, or more frequently for particularly heavy usage, and can be washed in a dishwasher. • Remove the filters one at a time by pushing them towards the back of the g...
Page 12 - AGA RANGEMASTER GROUP PLC