Powerware Powerware 9315 - Manuals
Powerware Powerware 9315 – Manual in PDF format online.
Manuals:
Manual Powerware Powerware 9315
Summary
Special Symbols The following are examples of symbols used on the UPS or accessories to alert you to important information: RISK OF ELECTRIC SHOCK - Observe the warning associated with the risk of electric shock symbol. CAUTION: REFER TO OPERATOR'S MANUAL - Refer to your operator's manual for additi...
EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com i Table of Contents 1 Introduction 1-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
TABLE OF CONTENTS EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com ii 5 Installing a Remote Emergency Power-off Control 5-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.1 REPO Installation ...
TABLE OF CONTENTS EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com iii 10.4 Optional Relay Interface Module 10-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
TABLE OF CONTENTS EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com iv 14 Product Specifications 14-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14....
EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com v List of Figures Figure 1‐1. Typical Powerware 9315 (500–750 kVA) UPS System 1-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figur...
EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 1-1 Chapter 1 Introduction The Eaton ® Powerware ® 9315 (500–750 kVA) uninterruptible power supply (UPS) is an online power protection system that prevents loss of valuable electronic infor...
INTRODUCTION EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 1-2 1.1 UPS Features The UPS has many standard features that provide cost‐effective and consistentlyreliable power protection. The descriptions in this section provide a brief ...
INTRODUCTION EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 1-3 1.2 Options and Accessories Contact your Eaton sales representative for information about the following options: 1.2.1 5% Input Filter The UPS can be equipped with an input...
INTRODUCTION EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 1-4 1.2.6 Monitoring and Communication The following monitoring and communication options are available: S Remote Monitor Panel (RMP) – An optional RMP contains backlit status ...
INTRODUCTION EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 1-5 1.4 Safety Warnings IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS S This manual contains important instructions that should be followed during installation and main...
INTRODUCTION EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 1-6 A V E R T I S S E M E N T ! S Les batteries peuvent présenter un risque de décharge électrique ou de brûlure par des courts‐circuits dehaute intensité. Prendre les précauti...
INTRODUCTION EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 1-7 1.7 Getting Help If you need help with any of the following: S Scheduling initial startup S Regional locations and telephone numbers S A question about any of the informati...
EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 1-1 Section I Installation
EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 2-1 Chapter 2 UPS Installation Plan and Unpacking Use the following basic sequence of steps to install the UPS: 1. Create an installation plan for the UPS system (Chapter 2). 2. Prepare you...
UPS INSTALLATION PLAN AND UNPACKING EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 2-2 2.1.3 Preparing for Wiring the UPS System For external wiring requirements, including the minimum AWG size of external wiring,see Table E through Tab...
EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 3-1 Chapter 3 Installing the UPS System This section describes the UPS system installation for single modules andmulti-modules, including: unloading the cabinets, UPS internal and external ...
INSTALLING THE UPS SYSTEM EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 3-2 3.2 Unloading the UPS Cabinets from the Pallet W A R N I N G S The UPS cabinets are heavy (see Table A on page A-1). If unpacking instructions are not closely ...
INSTALLING THE UPS SYSTEM EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 3-3 4. Connect the negative DC Link power wiring to the inverter input. Connect twocables to each inverter. 5. Reinstall the plastic shield to the inverter input s...
INSTALLING THE UPS SYSTEM EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 3-4 NOTE Remove the entire MBC top panel to punch conduit holes. 4. Connect phase A, B, and C power wiring from the bypass source to therespective bypass inputs in...
INSTALLING THE UPS SYSTEM EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 3-5 8. Connect the Output/Inverter 15‐pin control wiring harness connector to theInput/Rectifier 15‐pin control wiring harness connector. See Figure A‐12 onpage A-...
INSTALLING THE UPS SYSTEM EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 3-6 3.5 Installing Input/Rectifier Customer Connections NOTE If you are installing connections to the Battery I/O terminal connections and terminal board CB2TB, in...
INSTALLING THE UPS SYSTEM EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 3-7 3.9 Completing the Installation Checklist The final step in installing the UPS system is completing the following installationchecklist. This checklist ensures...
INSTALLING THE UPS SYSTEM EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 3-8 Installation Checklist - All packing materials and restraints have been removed from each cabinet. - Each cabinet in the UPS system is placed in its final inst...
INSTALLING THE UPS SYSTEM EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 3-9 Notes _________________________________________________________________________ _________________________________________________________________________ _____...
EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 4-1 Chapter 4 Installing a Remote Battery Disconnect The remote battery disconnect is crated separately for shipping. The enclosure isdesigned to be free‐standing. You can install a remote ...
INSTALLING A REMOTE BATTERY DISCONNECT EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 4-2 S Nominal voltages listed in this chapter are for a lead‐acid batteries rated per NEC at2.00 Vdc per cell. S Battery strings must be installed acc...
EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 5-1 Chapter 5 Installing a Remote Emergency Power-off Control A latching-type Remote Emergency Power-off (REPO) switch can be used in anemergency to shut down the UPS and remove power to th...
INSTALLING A REMOTE EMERGENCY POWER-OFF CONTROL EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 5-2 NOTE REPO switch rating is 6A/120 Vac or 3A/240 Vac. The REPO switch must be a latching-type switch with a dedicated circuit. REPO Switch...
EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 6-1 Chapter 6 Installing Optional Accessories This chapter contains installation information for the following options: S Monitoring accessories: Remote Monitor Panel (RMP), Relay Interface...
INSTALLING OPTIONAL ACCESSORIES EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 6-2 6.1 Installing an RMP As an option, you can install an RMP to monitor the UPS system operation fromvirtually any location within your facility, up to 152...
INSTALLING OPTIONAL ACCESSORIES EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 6-3 To install an RMP: 1. Verify that the UPS system is turned off and all power sources are removed. SeeChapter 9, “UPS Operating Instructions,” for shutdow...
INSTALLING OPTIONAL ACCESSORIES EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 6-4 6. Connect the RMP wiring to the terminal block using terminations shown inTable 6‐2. Table 6‐2. RMP Wire Terminations From RMP A To UPS Remarks TB1‐4 TB...
INSTALLING OPTIONAL ACCESSORIES EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 6-5 6.2 Installing an RIM The optional RIM uses relay contact closures to indicate the UPS system operatingstatus and alarm condition. The module uses an RS‐...
INSTALLING OPTIONAL ACCESSORIES EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 6-6 Connect to Port 1 (DB‐9) on Customer Interface Panel Fuse TerminalBlock(TB3) Figure 6‐4. Terminal Block Bracket 6. Connect RIM wiring to the terminal blo...
INSTALLING OPTIONAL ACCESSORIES EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 6-7 6.3 Installing an SCM The optional SCM shown in Figure 6‐5 provides contacts for monitoring UPS systemstatus. See Figure A‐29 page A-41 for enclosure dim...
INSTALLING OPTIONAL ACCESSORIES EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 6-8 Connect to Port 1 (DB‐9) on Customer Interface Panel Fuse TerminalBlock(TB3) Figure 6‐6. Terminal Block Bracket 6. Connect the SCM wiring to the terminal...
INSTALLING OPTIONAL ACCESSORIES EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 6-10 6.4 Installing X-Slot Cards NOTE LAN and telephone drops for use with X-Slot cards must be provided by facility planners or the customer. NOTE For setup...
EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 6-11 Section II Operation
EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 7-1 Chapter 7 Understanding UPS Operation The Powerware 9315 is a continuous duty, solid‐state UPS that supports thefollowing equipment: process control, data processing, telecommunications...
UNDERSTANDING UPS OPERATION EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 7-2 If utility power is interrupted or falls outside the parameters specified in Chapter 14,“Product Specifications,” the UPS uses a backup battery supply to mai...
UNDERSTANDING UPS OPERATION EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 7-3 7.1.1 Normal Mode In Normal mode, utility AC power is supplied to the rectifier. The rectifier supplies DCpower to the inverter, which then supplies the crit...
UNDERSTANDING UPS OPERATION EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 7-4 7.1.2 Bypass Mode The UPS automatically switches to Bypass mode if it detects an overload, load fault,or internal failure. The bypass source supplies the com...
UNDERSTANDING UPS OPERATION EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 7-5 7.1.3 Battery Mode The UPS transfers to Battery mode automatically if a utility power outage occurs, or ifthe utility power does not conform to specified par...
EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 8-1 Chapter 8 Using the Control Panel This chapter describes the UPS control panel, including controls and indicators, andhow to monitor UPS operation. The control panel is a black square a...
USING THE CONTROL PANEL EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 8-2 8.1 Using the LCD Screen The LCD screen at the top of the control panel provides an operator interface with theUPS system. Figure 8‐2 identifies the display fiel...
USING THE CONTROL PANEL EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 8-3 Use the LCD screen and the pushbuttons beneath it to: S Monitor UPS operation S Look at a log of UPS events (alarms, notices, and commands) 8.2 Using the Pushbut...
USING THE CONTROL PANEL EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 8-4 8.4 Reading the Status Indicators The six symbols on the left side of the control panel are status indicators. They arebacklit by colored LED lamps, and they wor...
USING THE CONTROL PANEL EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 8-5 8.5.1 System Meters Screen Figure 8‐4 shows the LCD screen as it appears when you first start the UPS. TheMeters menu is displayed in the menu box, with the Syst...
USING THE CONTROL PANEL EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 8-6 8.5.2 Load Amps Meters Screen Select Load Amps from the Meters menu to view a real‐time bar graph of the output current of the UPS. The graph shows the current f...
USING THE CONTROL PANEL EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 8-7 8.5.3 Software Versions Screen Select Versions from the Meters menu to view the software versions installed on the UPS. Figure 8‐6 shows the Software Versions sc...
USING THE CONTROL PANEL EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 8-8 8.5.4 Event History Log Screen Select History from the Events menu to display the Event History Log. The Event History Log lists up to 400 system events in chron...
USING THE CONTROL PANEL EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 8-9 8.5.5 Active System Events Screen Select Active from the Events menu to display a listing of all system events that are currently active. The most recent system ...
USING THE CONTROL PANEL EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 8-10 8.5.6 Unit Statistics Screen Select Unit from the Statistics menu to display a listing of statistics about UPS operation. Figure 8‐9 shows the Unit Statistics s...
USING THE CONTROL PANEL EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 8-11 8.5.7 Mimic Screen Select Mimic from the Graphics menu to display a real‐time graphical representation of the flow of current through the UPS. Figure 8‐10 shows...
USING THE CONTROL PANEL EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 8-12 8.5.8 Time Setup Screen Select Time from the Setup menu to display the Time Setup screen. The Time Setup screen allows you to set the internal time stamp of the...
USING THE CONTROL PANEL EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 8-13 8.5.9 Port Setup Screen Select Port 1 or Port 2 from the Setup menu to display one of the Port Setup screens. The Port Setup screens allow you to specify settin...
EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 9-1 Chapter 9 UPS Operating Instructions This chapter describes the UPS controls and instructions for operating the UPSsystem. NOTE Before starting the UPS, ensure all installation tasks ar...
UPS OPERATING INSTRUCTIONS EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 9-2 9.1.1 Control Panel The UPS control panel contains an LCD screen to display the current UPS systemstatus. You can view a statistical history and log of system...
UPS OPERATING INSTRUCTIONS EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 9-3 9.2 Starting the UPS To start the UPS system: NOTE This procedure assumes Automode is enabled. 1. Verify that the UPS circuit breakers are set as follows: UPS...
UPS OPERATING INSTRUCTIONS EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 9-4 13. If system is equipped with motor operated breaker CB2, proceed to Step 14;otherwise, proceed to Step 16. 14. Confirm UPS Battery Breaker CB2 has closed by...
UPS OPERATING INSTRUCTIONS EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 9-5 9.4 Transferring to Bypass Mode NOTE In the following step, holding the Mode key switch in the BYPASS position for three seconds transfers the load to Bypass ...
UPS OPERATING INSTRUCTIONS EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 9-6 9.6 Transferring to Bypass and Shutting Down the UPS To transfer the critical load to Bypass mode and shut down the UPS: 1. On the UPS, turn the Mode key swit...
UPS OPERATING INSTRUCTIONS EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 9-7 To restart the UPS after pressing the Emergency UPM Off pushbutton, follow theprocedure in paragraph 9.8.2, “Resetting the UPS System after an Emergency UPMOf...
EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 10-1 Chapter 10 Using Features and Options The many standard features of your UPS system provide consistent, economical, anddependable power protection. In addition, you can add available o...
USING FEATURES AND OPTIONS EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 10-2 10.3 Optional Remote Monitor Panel The optional Remote Monitor Panel (RMP) monitors the UPS system operating statusand alarm condition from virtually any loc...
USING FEATURES AND OPTIONS EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 10-4 10.4 Optional Relay Interface Module The optional Relay Interface Module (RIM) uses relay contact closures to indicate theoperating status and alarm conditio...
USING FEATURES AND OPTIONS EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 10-5 10.5 Optional Supervisory Contact Module An optional Supervisory Contact Module (SCM) establishes an interface between theParallel Capacity/Redundant system ...
EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 11-1 Chapter 11 Responding to System Events When the UPS system is operating in Normal mode, it continually monitors itself andthe incoming utility power. In Battery or Bypass modes, the UP...
EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 12-1 Chapter 12 Communication This chapter describes the communication features of the Powerware 9315 UPS andprovides information about connecting hardware, configuring the ports, changings...
COMMUNICATION EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 12-3 12.3 Configuring the Serial Ports Configure the communication port using the LCD screen and pushbuttons on the UPScontrol panel. Select Port 1 or Port 2 from the Setup me...
COMMUNICATION EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 12-4 Table 12‐3. Options Available for Each Communication Port Port 1 Port 2 Options X X Terminal Mode X X System Configuration Mode X Calibration Mode X Computer Mode X Remot...
COMMUNICATION EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 12-5 12.3.3 Data/Stop The data size and stop bits of the equipment connected to this port determine thenumber of bits transmitted per ASCII character. The data size and stop b...
COMMUNICATION EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 12-6 12.4 Terminal Mode In this mode, system events are continually logged through the serial port to thedevice connected to the port. Port 2 operates by default in Terminal m...
COMMUNICATION EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 12-7 12.4.2 Entire Log [Ctrl]+[P] The [Ctrl]+[P] key sequence prints the entire UPS Event History Log at the time thedata is requested. The printout begins with the oldest ala...
COMMUNICATION EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 12-8 12.4.3 Meters Printout [Ctrl]+[M] The [Ctrl]+[M] key sequence prints the current readings of the UPS system meters.The Input area shows the phase‐to‐phase voltage, freque...
COMMUNICATION EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 12-9 12.5 System Configuration Mode The System Configuration mode allows you to modify special functions in your UPS.These functions include programming of building alarms, cu...
COMMUNICATION EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 12-10 If you select 1 , 2 , or 3 from this menu, the following menu is displayed: Enable/Disable ( Function ) Enabled Building Alarm Number(s) 1 4 Enter E# to Enable Building ...
COMMUNICATION EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 12-11 At this level you can enter a custom message, 30 characters maximum, to displaywhen Building Alarm 1 is activated. If a custom message is entered to activate thebuilding...
COMMUNICATION EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 12-12 12.5.7 Battery Test Setup If Battery Test Setup (option 5 ) is selected from the Main menu (see page 12-9), the following menu is displayed: NOTE If a message stating “B...
COMMUNICATION EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 12-13 12.5.8 Modify Low Battery Time If Modify Low Battery Time (option 6 ) is selected from the Main menu (see page 12-9), the following menu is displayed: Modify Low Battery...
COMMUNICATION EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 12-14 12.9 eNotify Service The Powerware 9315 UPS supports Eaton's eNotify Remote Monitoring andDiagnostic Service. The eNotify Service is included at no charge during the fir...
COMMUNICATION EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 12-15 12.10 Remote Notification For connection and setup of a modem, or to enable Remote Notify and Call Homefeatures within the UPS, please contact Eaton (see page 1-7). Remo...
COMMUNICATION EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 12-16 12.11 X-Slot Cards The Powerware 9315 UPS has one factory‐installed X-Slot communication bay. SeeFigure A‐13 on page A-23 for the bay location. The UPS is compatible wit...
EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 13-1 Chapter 13 Maintaining the UPS System The components inside the UPS cabinet are secured to a sturdy metal frame that issupported by the UPS magnetics. This design allows authorized ser...
MAINTAINING THE UPS SYSTEM EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 13-2 13.2 Performing Preventive Maintenance The UPS system requires very little preventive maintenance. However, inspect theUPS system periodically to verify that...
MAINTAINING THE UPS SYSTEM EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 13-3 13.2.4 Battery Maintenance NOTE DO NOT DISCONNECT the batteries while the UPS is in Battery mode. Contact your Eaton service representative for battery maint...
EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 14-1 Chapter 14 Product Specifications The following sections detail the input, output, environmental, and batteryspecifications for the UPS. 14.1 Model Numbers The UPS systems are housed i...
PRODUCT SPECIFICATIONS EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 14-2 14.3 UPS System Output DC Filtering Ripple voltage less than 0.5% peak to peak UPS Output Capacity 100% rated current at 0.8 power factor or 100% rated current a...
EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com 15-1 Chapter 15 Warranty Limited Factory Warranty Three‐Phase Powerware UPS Products WARRANTOR: The warrantor for the limited warranties set forth herein is Eaton Electrical Inc., a Delawar...
EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com A-1 Appendix A Figur Installation Reference The information in this appendix will help you plan for and install the Powerware9315. This appendix contains the following information: S Physic...
INSTALLATION REFERENCE EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com A-2 6. The basic environmental requirements for UPS system operation are: S Ambient Temperature Range: 0–40°C (32–104°F) S Recommended Operating Range: 20–25°C (68–77...
INSTALLATION REFERENCE EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com A-3 DIMENSIONS ARE IN MILLIMETERS [INCHES] ÓÓÓÓÓÓÓÓÓ ÓÓÓÓÓÓÓÓÓ ÓÓÓÓÓÓÓÓÓ ÓÓÓÓÓÓÓÓÓ ÓÓÓÓÓÓÓÓÓ ÓÓÓÓÓÓÓÓÓ ÓÓÓÓÓÓÓÓÓ ÓÓÓÓÓÓÓÓÓ ÓÓÓÓÓÓÓÓÓ ÓÓÓÓÓÓÓÓÓ ÓÓÓÓÓÓÓÓÓ ÓÓÓÓÓÓÓÓÓ ÓÓÓ...
INSTALLATION REFERENCE EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com A-5 DIMENSIONS ARE IN MILLIMETERS [INCHES] ÓÓÓÓÓÓÓÓ ÓÓÓÓÓÓÓÓ ÓÓÓÓÓÓÓÓ ÓÓÓÓÓÓÓÓ ÓÓÓÓÓÓÓÓ ÓÓÓÓÓÓÓÓ ÓÓÓÓÓÓÓÓ ÓÓÓÓÓÓÓÓ ÓÓÓÓÓÓÓÓ ÓÓÓÓÓÓÓÓ ÓÓÓÓÓÓÓÓ ÓÓÓÓÓÓÓÓ ÓÓÓÓÓÓÓÓ ÓÓÓÓÓÓ...
INSTALLATION REFERENCE EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com A-7 DIMENSIONS ARE IN MILLIMETERS [INCHES] FRONT VIEW 2080.0 [ 38.2] 558.8[22.0] Figure A‐6. MBC – PCM 3 Dimensions
INSTALLATION REFERENCE EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com A-9 A.2 UPS System Oneline Configurations NOTE A bypass neutral feeder must be supplied when the output neutral is used. If no bypass neutral feeder is supplied, the ...
INSTALLATION REFERENCE EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com A-12 A.3 Power Wiring Installation Notes Read and understand the following notes while planning your installation: 1. Refer to national and local electrical codes for...
INSTALLATION REFERENCE EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com A-17 10. Per NEC, Article 300‐20(a), all three-phase conductors must be run in the sameconduit. If a neutral and/or ground is used, it must be run in the same conduit...
INSTALLATION REFERENCE EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com A-18 Table J. Recommended Installation Parts and Tool (Not Supplied by Eaton) Part Size Quantity Manufacturer Part Number Notes Long Barrel 2 Hole Lug 500 MCM As requ...
INSTALLATION REFERENCE EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com A-19 14. External overcurrent protection is not provided by this product, but is requiredby codes. See Table E through Table G starting on page A-13 for wiringrequire...
INSTALLATION REFERENCE EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com A-20 Table L. Maximum Output Circuit Breaker Ratings UPS Model Output Voltage Rating 400V 480V 600V PW9315-625/400PW9315-625/450 800A N/A N/A PW9315-625/500PW9315-625...
INSTALLATION REFERENCE EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com A-21 28. A battery disconnect switch is recommended, and may be required by NEC orlocal codes when batteries are remotely located. The battery disconnectswitch may be...
INSTALLATION REFERENCE EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com A-22 A.4 Location of UPS Terminals NOTE Metal shield covering power wiring terminals and battery compartment must be removed to gain access to wiring terminals. DC IN...
INSTALLATION REFERENCE EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com A-24 15 PIN INTERCABINETCONNECTION ONPIGTAIL HARNESSTO INPUT/ RECTIFIERCABINET NEGATIVE DC INPUTFROM RECTIFIER DC LINK(SEE FIGURE A‐15) AC OUTPUTTO MBC OR SBM(E9, E10...
INSTALLATION REFERENCE EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com A-26 AC INPUTTO BYPASS(E6, E7, E8)(A, B, C) GROUND OUTPUTNEUTRALCONNECTION(E12) STATIC SWITCH BACKFEEDPROTECTION BREAKER (FBP) AC INPUTFROM INVERTER(TOP TWO TERMINALH...
INSTALLATION REFERENCE EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com A-28 A.5 Customer Interface Wiring Notes 1. Use Class 1 wiring methods (as defined by the NEC) for control wiring. Installthe control wiring in separate conduit from ...
INSTALLATION REFERENCE EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com A-32 Table P. Output/Inverter Cabinet Customer Interface Connections CUSTJ4 Terminal Name Description 1 Building Alarm 2 Programmable UPS alarm. Activated by a remote...
INSTALLATION REFERENCE EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com A-34 Table Q. MBC Customer Interface Connections CUSTJ4 Terminal Name Description 1 Building Alarm 2 Programmable UPS alarm. Activated by a remote dry contact closure...
INSTALLATION REFERENCE EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com A-36 NOTE The Summary Alarm Relay contact rating is 32 Vac/42 Vdc maximum switched voltage and 1A maximum current. NOTE Relays are shown in de‐energized state. Relays...
INSTALLATION REFERENCE EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com A-37 DIMENSIONS ARE IN MILLIMETERS [INCHES] NOTE Interface wiring and conduit between the REPO switch and the UPS are to be supplied by the customer. 115.8[4.56] 114....
INSTALLATION REFERENCE EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com A-38 A.7 RMP Dimensions and Mounting Details DIMENSIONS ARE IN MILLIMETERS [INCHES] 100.1[3.94] 74.7 [2.94] 171.5[6.75] 25.4 [1.00] KNOCKOUTS PROVIDED ON5 SURFACES 28...
INSTALLATION REFERENCE EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com A-39 A.8 RIM Dimensions and Mounting Details DIMENSIONS ARE IN MILLIMETERS [INCHES] 28.6 [1.12] FLUSH MOUNT 215.9[8.50] 196.8[7.75] 41.1 [1.62] 88.9 [3.50] 190.5[7.50...
INSTALLATION REFERENCE EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com A-41 A.9 SCM Dimensions and Mounting Details 41.1 DIMENSIONS ARE IN MILLIMETERS [INCHES] 100.1[3.94] 74.7 [2.94] 171.5[6.75] 25.4 [1.00] KNOCKOUTS PROVIDED ON5 SURFAC...
INSTALLATION REFERENCE EATON Powerware ® 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201244 Rev E www.powerware.com A-42 A.10 Battery Disconnect Switch Dimensions DIMENSIONS ARE IN MILLIMETERS [INCHES] 806.5 [31.75] 870.0 [34.25] 88.9 [3.50] 438.15[17.25] REMOVABLE FEET (IF WALL MO...
Powerware Manuals
-
Powerware 5110
Manual
-
Powerware 9315 UPS
Manual
-
Powerware 9125
Manual
-
Powerware 100160 kVA
Manual
-
Powerware 700 VA
Manual
-
Powerware 10001500 VA
Manual
-
Powerware 1085
Manual
-
Powerware 9315
Manual
-
Powerware 10001100 kVA
Manual
-
Powerware 2500
Manual
-
Powerware 15 KVA
Manual
-
Powerware IPK-0318
Manual
-
Powerware 5125
Manual
-
Powerware 5115A USB
Manual
-
Powerware 5140
Manual
-
Powerware IPK-0320
Manual
-
Powerware 3115
Manual
-
Powerware 5105
Manual
-
Powerware 6000 VA
Manual
-
Powerware Powerware 9390
Manual